Cited by 129Reproductive Health and ContraceptionInternational Human Rights and Reproductive LawReproductive System and Pregnancy

Extended use up to 5 years of the etonogestrel-releasing subdermal contraceptive implant: comparison to levonorgestrel-releasing subdermal implant

Open access
Ali, Moazzam, Akin, Ayse, Bahamondes, Luis, Brache, Vivian, Habib, Ndema, Landoulsi, Sihem, Hubacher, David·2016·Human Reproduction

Abstract

STUDY QUESTION: Is it possible to extend the use of the 3-year one-rod etonogestrel (ENG)-releasing subdermal contraceptive implant to 5 years? SUMMARY ANSWER: The extended use of the one-rod ENG-releasing subdermal contraceptive implant showed 100% efficacy in years 4 and 5. WHAT IS KNOWN ALREADY: The initial regulated trials on the ENG-releasing subdermal contraceptive implant conducted in the 1990 s were designed to measure cumulative 3-year efficacy. The ENG-implant has both well established safety and efficacy for up to 3 years. Pharmacokinetic data on ENG show high levels at 3 years and some previous clinical research confirms efficacy beyond the current approved duration of 3 years. Today, many women, because the labeled duration has been reached, have the ENG implant removed at 3 years, increasing costs, inconvenience and risks. STUDY DESIGN SIZE, DURATION: For the first 3 years, this study was an open-label, multi-centre randomized trial comparing the 3-year ENG implant to the 5-year levonorgestrel (LNG)-releasing implant. After 3 years, a subset of 390 ENG participants, consented to extended use. We compared efficacy, side effects and removal procedures of both implants. We used Kaplan-Meier (K-M) analysis. We included an observational cohort of copper intrauterine device (IUD) users as non-users of hormonal contraceptive method for comparative purposes. PARTICIPANTS/MATERIALS, SETTING, METHODS: The study took place in family planning clinics in seven countries worldwide. Women were enlisted after an eligibility check and informed consent, and 1328 women were enrolled: 390, 522 and 416 in the ENG-implant, LNG-implant and IUD groups, respectively. MAIN RESULTS AND THE ROLE OF CHANCE: Over 200 women used the ENG implant for at least 5 years. No pregnancies occurred during the additional 2 years of follow up in the ENG or LNG implant group. The overall 5-year K-M cumulative pregnancy rates for ENG- and LNG- implants were 0.6 per 100 women-years (W-Y) [95% confidence interval (CI): 0.2-1.8] and 0.8 per 100 W-Y [95% CI: 0.2-2.3], respectively. Complaints of bleeding changes were similar; however, ENG-users were more likely than LNG-users to experience heavy bleeding (p < 0.05). The median duration of the implant removal procedure was 64 seconds shorter for the one-rod ENG-implant (inter-quartile range (IQR) = 30.5, 117.5) compared to the two-rod LNG product (IQR = 77.0, 180.0). The 2-year rate for pregnancy in the IUD group compared with the two implant groups combined was 4.1 per 100 W-Y [95% CI: 2.5-6.5]. LIMITATIONS, REASONS FOR CAUTION: Few women were ≤19 years old or nulligravida. Although there was no weight limit for enrolment in the study, the number of women ≥70 kg were few. WIDER IMPLICATIONS OF THE FINDINGS: The results from this study corroborate previous evidence showing high contraceptive efficacy through 4 years for the ENG-implant. Data through 5 years are a novel contribution and further proof of the product's capability to provide safe and effective contraception that rivals the current 5-year LNG-subdermal implant. The findings provide valuable information for policy makers, family planning programmers and clinicians that the ENG-releasing subdermal implant is still highly effective up to 5 years after insertion. Compared to previous efforts, our study population was geographically diverse and our study had the highest number of participants completing at least 5 years of use. TRIAL REGISTRATION: The trial was registered as ISRCTN33378571. STUDY FUNDING/COMPETING INTERESTS: The contraceptive devices and funds for conduct of the study were provided by the United Nations Development Programme/United Nations Population Fund/World Health Organization (WHO)/UNICEF/World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP), Department of Reproductive Health and Research (RHR), WHO. This report contains the collective views of an international group of experts, and does not necessarily represent the decisions or the stated policy of the WHO. All stated authors have no conflict of interest, except Dr Hubacher who reported grants from United States Agency for International Development, during the conduct of the study; other from Advisory Boards (Teva, Bayer, OCON), outside the submitted work.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humrep/dew222

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

1 retracted

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ali, M., Akin, A., Bahamondes, L., Brache, V., Habib, N., Landoulsi, S., & Hubacher, D.
Affiliations
  • World Health Organization (CH)
  • Universidade Estadual de Campinas (UNICAMP) (BR)
  • Profamilia (DO)
  • Family Health International 360 (US)
Corresponding author
Ali, Moazzam
Venue
Human Reproduction
Published
2016-09-26
Volume
31
Issue
11
Pages
2491-2498
ISSN
  • 0268-1161 (ISSN-L)
  • 1460-2350
OpenAlex
W2525824154
Cited by
129
References
9
Citations by year
2026: 11 · 2025: 17 · 2024: 21 · 2023: 13 · 2022: 7 · 2021: 13 · 2020: 16 · 2019: 10 · 2018: 10 · 2017: 9 · 2016: 2
FWCI
10.25
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Human Reproduction (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
Funders
  • United States Agency for International Development
  • World Health Organization
  • Teva Pharmaceutical Industries
  • UNICEF
  • United Nations Population Fund
  • United Nations Development Programme
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Reproductive Health and Contraception
  • Social Sciences › Political Science and International Relations › International Human Rights and Reproductive Law
  • Life Sciences › Immunology and Microbiology › Immunology › Reproductive System and Pregnancy
Keywords
contraceptive efficacy, pregnancy rate, implant removal, copper intrauterine device, hormonal contraception, long-acting reversible contraception, family planning clinics
MeSH terms
Adolescent, Adult, Contraceptive Agents, Female, Drug Implants, Family Planning Services, Female, Humans, Treatment Outcome, Levonorgestrel, Desogestrel, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review