The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Antibacterial poly(D,L-lactic acid) coating of medical implants using a biodegradable drug delivery technology
Open accessAbstract
OBJECTIVES: Biomaterial-associated bacterial infections present common and challenging complications with medical implants. The purpose of this study was to determine the antibacterial properties of a low molecular weight biodegradable poly(D,L-lactic acid) coating with integrated antibiotics gentamicin and teicoplanin. METHODS: Coating of Kirschner-wires was carried out by a solvent casting technique under aseptic conditions with and without incorporated antibiotics. Release kinetics of gentamicin and teicoplanin were studied in phosphate-buffered saline. Initial bacterial adhesion of Staphylococcus epidermidis on coated and bare implants was determined by radiolabelling and counts of detached viable organisms. RESULTS: The incorporated antibiotics showed a continuous release over a period of at least 96 h with an initial peak of release in the first 6 h. Attachment of non-viable microorganisms, detected by radiolabelled bacteria, was increased significantly by the polymer coatings (P < 0.05). In contrast, the number of viable bacteria was reduced by the pure polymer (P < 0.01) and further by the polymer-antibiotic combinations (P < 0.05). CONCLUSIONS: Poly(D,L-lactic acid) coating of implants could offer new perspectives in preventing biomaterial-associated infections. Combinations with other drugs to formulate custom-tailored implant surfaces are feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
Cited by
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Bahar, A., & Ren, D. (2013) · Pharmaceuticals · doi:10.3390/ph6121543 · Cited by 1,351
A Review on Biomedical Titanium Alloys: Recent Progress and Prospect
Zhang, L., & Chen, L. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201801215 · Cited by 1,100
Current development of biodegradable polymeric materials for biomedical applications
Song, R., Murphy, M., Li, C., Ting, K., Soo, C., & Zheng, Z. (2018) · Drug Design, Development and Therapy · doi:10.2147/dddt.s165440 · Cited by 915
Antibiotic-eluting medical devices for various applications
ZILBERMAN, M., & ELSNER, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.05.020 · Cited by 610
ANTIBIOTIC-LOADED BONE CEMENT FOR INFECTION PROPHYLAXIS IN TOTAL JOINT REPLACEMENT
JIRANEK, W. A., HANSSEN, A. D., & GREENWALD, A. S. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200611000-00024 · Cited by 411
Gao, G., Lange, D., Hilpert, K., Kindrachuk, J., Zou, Y., Cheng, J. T. J., Kazemzadeh-Narbat, M., Yu, K., Wang, R., Straus, S. K., et al. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.013 · Cited by 388
Staphylococci and implant surfaces: a review
Harris, L. G., & Richards, R. G. (2006) · Injury · doi:10.1016/j.injury.2006.04.003 · Cited by 385
Biofilm formation, bacterial adhesion and host response on polymeric implants—issues and prevention
Pavithra, D., & Doble, M. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034003 · Cited by 371
Biomaterial and antibiotic strategies for peri‐implantitis: A review
Norowski, P. A., & Bumgardner, J. D. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31152 · Cited by 339
Bone tissue engineering scaffolding: computer-aided scaffolding techniques
Thavornyutikarn, B., Chantarapanich, N., Sitthiseripratip, K., Thouas, G. A., & Chen, Q. (2014) · Progress in Biomaterials · doi:10.1007/s40204-014-0026-7 · Cited by 325
A novel antibacterial titania coating: Metal ion toxicity and in vitro surface colonization
Heidenau, F., Mittelmeier, W., Detsch, R., Haenle, M., Stenzel, F., Ziegler, G., & Gollwitzer, H. (2005) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-005-4422-3 · Cited by 324
Self-citationAntifouling and antimicrobial biomaterials: an overview
Francolini, I., Vuotto, C., Piozzi, A., & Donelli, G. (2017) · APMIS · doi:10.1111/apm.12675 · Cited by 322
Davachi, S. M., & Kaffashi, B. (2015) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2014.979507 · Cited by 156
“On the contrary the number of viable bacteria was reduced by the pure polymer([142]).”
BackgroundGollwitzer, H., Thomas, P., Diehl, P., Steinhauser, E., Summer, B., Barnstorf, S., Gerdesmeyer, L., Mittelmeier, W., & Stemberger, A. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2005.02.003 · Cited by 67
Self-citationImplant Healing in Experimental Animal Models of Diabetes
Le, N. N., Rose, M. B., Levinson, H., & Klitzman, B. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500315 · Cited by 52
Metadata
- Authors
- Gollwitzer, H.
- Venue
- Journal of Antimicrobial Chemotherapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-01-28
- Volume
- 51
- Issue
- 3
- Pages
- 585-591
- ISSN
- 0305-7453 (ISSN-L)
- 1460-2091
- OpenAlex
- W2157266521
- Cited by
- 216
- References
- 1
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.