Antimicrobial efficacy of a new antibiotic-loaded poly(hydroxybutyric-co-hydroxyvaleric acid) controlled release system
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Failure of orthopaedic devices, mainly femoral hip replacements, due to infection is of increasing medical importance. There is a need for improved antibiotic delivery systems in the treatment of orthopaedic infections and here we have evaluated polyhydroxyalkanoate formulations for their suitability as a constant delivery system for gentamicin. METHODS: Gentamicin was incorporated in poly(hydroxybutyric-co-hydroxyvalerate) (PHBV) with 8% or 12% hydroxyvalerate (HV) content at 2:1 or 5:1 (weight to weight) ratio. In conjunction with an elution study, a scanning electron microscopy and a porosity study were carried out to explore physical characteristics of the complexes before and after the leaching effect. The antibacterial effectiveness of the complexes was analysed in a bacterial adhesion assay using clinical isolates of Staphylococcus haemolyticus and Staphylococcus aureus. In addition, the polymers were exposed to pooled human blood to test their biocompatibility in both static and dynamic environments. RESULTS: We have shown that increasing the HV content from 8% to 12% leads to a faster release of the integrated antibiotic. An increase in antibiotic content enhanced the homogeneity while decreasing the permeability of the complexes and reducing the release rate. A significant reduction in the number of the adherent S. aureus and gentamicin-resistant S. haemolyticus within a 48 h exposure to our formulations confirmed the effectiveness of the PHBV/gentamicin complexes. Finally, these formulations did not alter the haemodynamics of the pooled blood samples after an extended period of time. CONCLUSION: Taken together, the PHBV/gentamicin formulations may prove to be effective preventive therapeutic modalities in implant-related Staphylococcus infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sanders, J. E., Bale, S. D., & Neumann, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10285 · Cited by 82
Cited by
Polymeric materials with antimicrobial activity
Muñoz-Bonilla, A., & Fernández-García, M. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.005 · Cited by 1,221
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
Antibiotic-eluting medical devices for various applications
ZILBERMAN, M., & ELSNER, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.05.020 · Cited by 610
Bone tissue engineering therapeutics: controlled drug delivery in three-dimensional scaffolds
Mouriño, V., & Boccaccini, A. R. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0379 · Cited by 527
Antibacterial surfaces for biomedical devices
Vasilev, K., Cook, J., & Griesser, H. J. (2009) · Expert Review of Medical Devices · doi:10.1586/erd.09.36 · Cited by 504
Metadata
- Authors
- Rossi, S., Azghani, A. O., & Omri, A.
- Venue
- Journal of Antimicrobial Chemotherapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-01
- Volume
- 54
- Issue
- 6
- Pages
- 1013-1018
- ISSN
- 0305-7453 (ISSN-L)
- 1460-2091
- OpenAlex
- W2160848453
- Cited by
- 100
- References
- 1
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.