Objective: To illustrate the problem of subpopulation miscalibration, to adapt an algorithm for recalibration of the predictions, and to validate its performance. Materials and Methods: In this retrospective cohort study, we evaluated the calibration of predictions based on the Pooled Cohort Equations (PCE) and the fracture risk assessment tool (FRAX) in the overall population and in subpopulations defined by the intersection of age, sex, ethnicity, socioeconomic status, and immigration history. We next applied the recalibration algorithm and assessed the change in calibration metrics, including calibration-in-the-large. Results: 1 021 041 patients were included in the PCE population, and 1 116 324 patients were included in the FRAX population. Baseline overall model calibration of the 2 tested models was good, but calibration in a substantial portion of the subpopulations was poor. After applying the algorithm, subpopulation calibration statistics were greatly improved, with the variance of the calibration-in-the-large values across all subpopulations reduced by 98.8% and 94.3% in the PCE and FRAX models, respectively. Discussion: Prediction models in medicine are increasingly common. Calibration, the agreement between predicted and observed risks, is commonly poor for subpopulations that were underrepresented in the development set of the models, resulting in bias and reduced performance for these subpopulations. In this work, we empirically evaluated an adapted version of the fairness algorithm designed by Hebert-Johnson et al. (2017) and demonstrated its use in improving subpopulation miscalibration. Conclusion: A postprocessing and model-independent fairness algorithm for recalibration of predictive models greatly decreases the bias of subpopulation miscalibration and thus increases fairness and equality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
General Cardiovascular Risk Profile for Use in Primary Care: The Framingham Heart Study
D’Agostino, R. B., Vasan, R. S., Pencina, M. J., Wolf, P. A., Cobain, M., Massaro, J. M., & Kannel, W. B. (2008) · Circulation · doi:10.1161/circulationaha.107.699579 · Cited by 7,491
Dissecting racial bias in an algorithm used to manage the health of populations
Obermeyer, Z., Powers, B., Vogeli, C., & Mullainathan, S. (2019) · Science · doi:10.1126/science.aax2342 · Cited by 7,137 · cited 1×
“As another example, an algorithm that recommends which patients should receive additional help presents bias against Black patients, as it mimics a trend in retrospective data in which Black patients utilized less healthcare.(12) A different source of bias and unfairness can stem from the modeling process itself.”
Method2013 ACC/AHA Guideline on the Assessment of Cardiovascular Risk
Goff, D. C., Lloyd-Jones, D. M., Bennett, G., Coady, S., D’Agostino, R. B., Gibbons, R., Greenland, P., Lackland, D. T., Levy, D., O’Donnell, C. J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.005 · Cited by 4,945
Self-citationMulti-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942
Clinical Prediction Models: A Practical Approach to Development, Validation, and Updating
Steyerberg, E. W. (2019) · Statistics for Biology and Health · doi:10.1007/978-3-030-16399-0 · Cited by 3,281
Equality of Opportunity in Supervised Learning
Hardt, M., Price, E., & Srebro, N. (2016) · arXiv · doi:10.48550/arxiv.1610.02413 · Cited by 2,536
FRAX™ and the assessment of fracture probability in men and women from the UK
Kanis, J. A., Johnell, O., Oden, A., Johansson, H., & McCloskey, E. (2008) · Osteoporosis International · doi:10.1007/s00198-007-0543-5 · Cited by 2,467
Fair prediction with disparate impact: a study of bias in recidivism prediction instruments
Chouldechova, A. (2017) · Big Data · doi:10.1089/big.2016.0047 · Cited by 2,159 · cited 1×
“Another drawback is that, in all but the most trivial settings, false positive rates, false negative rates, and equal calibration cannot all be obtained simultaneously.(31)”
BackgroundD'Agostino, R. B., Grundy, S., Sullivan, L. M., Wilson, P., & for the CHD Risk Prediction Group (2001) · JAMA · doi:10.1001/jama.286.2.180 · Cited by 2,108
Hidden in Plain Sight — Reconsidering the Use of Race Correction in Clinical Algorithms
Vyas, D. A., Eisenstein, L. G., & Jones, D. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmms2004740 · Cited by 1,731
Cited by
Wang, H. E., Landers, M., Adams, R., Subbaswamy, A., Kharrazi, H., Gaskin, D. J., & Saria, S. (2022) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocac065 · Cited by 63
A scoping review of fair machine learning techniques when using real-world data
Huang, Y., Guo, J., Chen, W.-H., Lin, H.-Y., Tang, H., Wang, F., Xu, H., & Bian, J. (2024) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2024.104622 · Cited by 61
Davis, S. E., Dorn, C., Park, D. J., & Matheny, M. E. (2025) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaf039 · Cited by 43
Pfohl, S., Xu, Y., Foryciarz, A., Ignatiadis, N., Genkins, J., & Shah, N. (2022) · 2022 ACM Conference on Fairness Accountability and Transparency · doi:10.1145/3531146.3533166 · Cited by 30
MIMIC-IF: Interpretability and Fairness Evaluation of Deep Learning Models on MIMIC-IV Dataset
Meng, C., Trinh, L., Xu, N., & Liu, Y. (2021) · doi:10.21203/rs.3.rs-402058/v1 · Cited by 21
Equity and AI Governance at Academic Medical Centers
(2024) · The American Journal of Managed Care · doi:10.37765/ajmc.2024.89555 · Cited by 12
Metadata
- Authors
- Barda, N., Yona, G., Rothblum, G. N., Greenland, P., Leibowitz, M., Balicer, R., Bachmat, E., & Dagan, N.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-11-24
- Volume
- 28
- Issue
- 3
- Pages
- 549-558
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W3107969206
- Cited by
- 59
- References
- 18
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.