CoChat

Automated medical literature screening using artificial intelligence: a systematic review and meta-analysis

Open access
Feng, Yunying, Liang, Siyu, Zhang, Yuelun, Chen, Shi, Wang, Qing, Huang, Tianze, Sun, Feng, Liu, Xiaoqing, Zhu, Huijuan, Pan, Hui · 2022 · Journal of the American Medical Informatics Association
Cited by 59

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Objective: We aim to investigate the application and accuracy of artificial intelligence (AI) methods for automated medical literature screening for systematic reviews. Materials and Methods: We systematically searched PubMed, Embase, and IEEE Xplore Digital Library to identify potentially relevant studies. We included studies in automated literature screening that reported study question, source of dataset, and developed algorithm models for literature screening. The literature screening results by human investigators were considered to be the reference standard. Quantitative synthesis of the accuracy was conducted using a bivariate model. Results: Eighty-six studies were included in our systematic review and 17 studies were further included for meta-analysis. The combined recall, specificity, and precision were 0.928 [95% confidence interval (CI), 0.878–0.958], 0.647 (95% CI, 0.442–0.809), and 0.200 (95% CI, 0.135–0.287) when achieving maximized recall, but were 0.708 (95% CI, 0.570–0.816), 0.921 (95% CI, 0.824–0.967), and 0.461 (95% CI, 0.375–0.549) when achieving maximized precision in the AI models. No significant difference was found in recall among subgroup analyses including the algorithms, the number of screened literatures, and the fraction of included literatures. Discussion and Conclusion: This systematic review and meta-analysis study showed that the recall is more important than the specificity or precision in literature screening, and a recall over 0.95 should be prioritized. We recommend to report the effectiveness indices of automatic algorithms separately. At the current stage manual literature screening is still indispensable for medical systematic reviews.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jamia/ocac066

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 59

Metadata

Authors
Feng, Y., Liang, S., Zhang, Y., Chen, S., Wang, Q., Huang, T., Sun, F., Liu, X., Zhu, H., & Pan, H.
Venue
Journal of the American Medical Informatics Association
Published
2022-05-31
Volume
29
Issue
8
Pages
1425-1432
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W4282937925
Cited by
59
References
18
FWCI
4.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated medical literature screening using artificial intelligence: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1093/jamia/ocac066
The paper
Feng, Y., Liang, S., Zhang, Y., Chen, S., Wang, Q., Huang, T., Sun, F., Liu, X., Zhu, H., & Pan, H. (2022). Automated medical literature screening using artificial intelligence: a systematic review and meta-analysis. Journal of the American Medical Informatics Association. https://doi.org/10.1093/jamia/ocac066

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.