CoChat

Drug-drug interaction checking assisted by clinical decision support: a return on investment analysis

Open access
Helmons, Pieter J, Suijkerbuijk, Bas O, Nannan Panday, Prashant V, Kosterink, Jos GW · 2015 · Journal of the American Medical Informatics Association
Cited by 71

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background Drug-drug interactions (DDIs) are very prevalent in hospitalized patients. Objectives To determine the number of DDI alerts, time saved, and time invested after suppressing clinically irrelevant alerts and adding clinical-decision support to relevant alerts. Materials and methods The most frequently occurring DDIs were evaluated for clinical relevance by a multidisciplinary expert panel. Pharmacist evaluation of relevant DDIs was facilitated using computerized decision support systems (CDSS). During Phase 1, only CDSS-assisted DDI checking was implemented. During Phase 2, CDSS-assisted DDI checking remained in place, and clinically irrelevant DDIs were suppressed. In each phase, the number of alerts and duration of pharmacist DDI checking were compared to conventional DDI checking. In addition, the time invested to implement and configure the CDSS was compared to the time saved using CDSS-assisted DDI checking. Results CDSS-assisted DDI checking resulted in a daily decrease of DDI checking alerts from 65 to 47 alerts in Phase 1 (P = .03) and from 73 to 33 alerts in Phase 2 (P = .003). DDI checking duration decreased from 15 to 11 minutes (P = .044) and from 15½ to 8½ minutes (P = .001) in Phases 1 and 2, respectively. Almost 298 of the 392 hours required for implementation were invested by pharmacists. An annual timesaving of 30 hours yielded a return on investment of 9.8 years. Conclusion CDSS-assisted DDI checking resulted in a 55% reduction of the number of alerts and a 45% reduction in time spent on DDI checking, yielding a return on investment of almost 10 years. Our approach can be used to refine other drug safety checking modules, increasing the efficiency of checking for drug safety without the need to add more staff pharmacists.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jamia/ocu010

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Helmons, P. J., Suijkerbuijk, B. O., Nannan Panday, P. V., & Kosterink, J. G.
Venue
Journal of the American Medical Informatics Association
Published
2015-02-10
Volume
22
Issue
4
Pages
764-772
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2150627342
Cited by
71
References
5
FWCI
7.14
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.