Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics
Open accessThe DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Abstract
Objective Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients’ perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients’ task performance, satisfaction, and the relationship of these measures to user characteristics. Materials and Methods We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Results Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Discussion Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Conclusion Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients’ experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“We used standardized methods for usability studies of mobile health systems to assess effectiveness, efficiency, and satisfaction from the International Organization for Standardization 9241-11.30,42”
From A chatbot for hypertension self-management support: user-centered design, development, and usability testing (2023) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · Cited by 9,879
SUS: A 'Quick and Dirty' Usability Scale
(1996) · Usability Evaluation In Industry · doi:10.1201/9781498710411-35 · Cited by 8,989
(1993) · Elsevier eBooks · doi:10.1016/c2009-0-21512-1 · Cited by 5,504
An Empirical Evaluation of the System Usability Scale
Bangor, A., Kortum, P. T., & Miller, J. T. (2008) · International Journal of Human–Computer Interaction · doi:10.1080/10447310802205776 · Cited by 5,181
Usability Evaluation In Industry
(1996) · CRC Press eBooks · doi:10.1201/9781498710411 · Cited by 4,354
A mathematical model of the finding of usability problems
Nielsen, J., & Landauer, T. K. (1993) · Proceedings of the SIGCHI conference on Human factors in computing systems - CHI '93 · doi:10.1145/169059.169166 · Cited by 1,961
Nielsen, J. (1994) · Cited by 1,897
(2013) · Journal of Usability Studies archive · Cited by 1,357
The Factor Structure of the System Usability Scale
Lewis, J. R., & Sauro, J. (2009) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-02806-9_12 · Cited by 1,278
Refining the Test Phase of Usability Evaluation: How Many Subjects Is Enough?
Virzi, R. A. (1992) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872089203400407 · Cited by 1,190
Research works printed but not linked: 5
- International Telecommunications Union, 2014, The World in 2014: ICT Facts and Figures
- CTIA -The Wireless Association, 2014, Wireless Industry Survey 2013
- Nielsen, 2000, Why You Only Need to Test with 5 Users
- TechSmith Corporation, 2014, Morae Usability Testing and Market Research Software
- IBM Corporation, 2013, IBM SPSS Statistics for Windows
Cited by
Telehealth and patient satisfaction: a systematic review and narrative analysis
Kruse, C. S., Krowski, N., Rodriguez, B., Tran, L., Vela, J., & Brooks, M. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-016242 · Cited by 1,350
Lattie, E. G., Adkins, E. C., Winquist, N., Stiles-Shields, C., Wafford, Q. E., & Graham, A. K. (2019) · Journal of Medical Internet Research · doi:10.2196/12869 · Cited by 843
“Furthermore, in recent years, increased focus has been on assessing the user experience (including the usability and acceptability) of such interventions to identify and rectify user experience failings that could limit one’s ability and desire to continue to use a program [23-25].”
O’Connor, S., Hanlon, P., O’Donnell, C. A., Garcia, S., Glanville, J., & Mair, F. S. (2016) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-016-0359-3 · Cited by 636
Usability of Commercially Available Mobile Applications for Diverse Patients
Sarkar, U., Gourley, G. I., Lyles, C. R., Tieu, L., Clarity, C., Newmark, L., Singh, K., & Bates, D. W. (2016) · Journal of General Internal Medicine · doi:10.1007/s11606-016-3771-6 · Cited by 257
Schnall, R., Cho, H., & Liu, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.8851 · Cited by 239
Metadata
- Authors
- Georgsson, M., & Staggers, N.
- Affiliations
- University of Utah (US)
- University of Maryland, Baltimore (US)
- Corresponding author
- Georgsson, Mattias
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-09-16
- Volume
- 23
- Issue
- 1
- Pages
- 5-11
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC4713903
- OpenAlex
- W2177887065
- Semantic Scholar
- 424879d126d8ebf5423079e3e55d8c21114440e5
- Cited by
- 200
- References
- 43
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 22 · 2023: 16 · 2022: 23 · 2021: 31 · 2020: 29 · 2019: 21 · 2018: 15 · 2017: 12 · 2016: 8
- FWCI
- 21.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of the American Medical Informatics Association (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Topics
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Health Sciences › Health Professions › Health Information Management › Health, Technology, Consumer Behavior
- Keywords
- mobile health, diabetes management, usability evaluation, ISO 9241-11, System Usability Scale, user satisfaction, user characteristics, chronic disease management, time on task, task errors, computer experience
- MeSH terms
- Adult, Age Factors, Aged, Consumer Behavior, Diabetes Mellitus, Efficiency, Female, Humans, Male, Middle Aged, Self Care, User-Computer Interface, Patient Satisfaction, Telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics. https://app.cochat.ai/papers/10.1093/jamia/ocv099
- The paper
- Georgsson, M., & Staggers, N. (2016). Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics. Journal of the American Medical Informatics Association. https://doi.org/10.1093/jamia/ocv099
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.