The DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
SMART on FHIR: a standards-based, interoperable apps platform for electronic health records
Open accessAbstract
Objective In early 2010, Harvard Medical School and Boston Children’s Hospital began an interoperability project with the distinctive goal of developing a platform to enable medical applications to be written once and run unmodified across different healthcare IT systems. The project was called Substitutable Medical Applications and Reusable Technologies (SMART). Methods We adopted contemporary web standards for application programming interface transport, authorization, and user interface, and standard medical terminologies for coded data. In our initial design, we created our own openly licensed clinical data models to enforce consistency and simplicity. During the second half of 2013, we updated SMART to take advantage of the clinical data models and the application-programming interface described in a new, openly licensed Health Level Seven draft standard called Fast Health Interoperability Resources (FHIR). Signaling our adoption of the emerging FHIR standard, we called the new platform SMART on FHIR. Results We introduced the SMART on FHIR platform with a demonstration that included several commercial healthcare IT vendors and app developers showcasing prototypes at the Health Information Management Systems Society conference in February 2014. This established the feasibility of SMART on FHIR, while highlighting the need for commonly accepted pragmatic constraints on the base FHIR specification. Conclusion In this paper, we describe the creation of SMART on FHIR, relate the experience of the vendors and developers who built SMART on FHIR prototypes, and discuss some challenges in going from early industry prototyping to industry-wide production use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Recently, a flexible data structure called FHIR (Fast Healthcare Interoperability Resources)28 was developed to represent clinical data in a consistent, hierarchical, and extensible container format, regardless of the health system, which simplifies data interchange between sites.”
From Scalable and accurate deep learning with electronic health records (2018) · cites this paper as [28]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This setup results in the HL7 legacy versions (ie, v2, v3, CDA) to be unable to implement SMART applications.”
From The Fast Health Interoperability Resources (FHIR) Standard: Systematic Literature Review of Implementations, Applications, Challenges and Opportunities (2021) · cites this paper as [3]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“All previous versions could not use a web API for data access and were unable to access data at the granular level.”
From The Fast Health Interoperability Resources (FHIR) Standard: Systematic Literature Review of Implementations, Applications, Challenges and Opportunities (2021) · cites this paper as [3]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Additionally, the CDA is based on the reference information model and is lacking in sufficient detail”
From The Fast Health Interoperability Resources (FHIR) Standard: Systematic Literature Review of Implementations, Applications, Challenges and Opportunities (2021) · cites this paper as [3]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Combining these data with those derived from EHRs-using standards such as the Fast Healthcare Interoperability Resources, a global industry standard for exchanging healthcare data 51 -to query relevant information about a patient's underlying disease risk could create a more personalized remote monitoring experience for patients and caregivers.”
From Multimodal biomedical AI (2022) · cites this paper as [51]
Experimental — accuracy not yet measured
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252
Leitman, M., Lysyansky, P., Sidenko, S., Shir, V., Peleg, E., Binenbaum, M., Kaluski, E., Krakover, R., & Vered, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.06.019 · Cited by 1,187
Urheim, S., Edvardsen, T., Torp, H., Angelsen, B., & Smiseth, O. A. (2000) · Circulation · doi:10.1161/01.cir.102.10.1158 · Cited by 1,078
Real-Time Strain Rate Imaging of the Left Ventricle by Ultrasound
Heimdal, A., Støylen, A., Torp, H., & Skjærpe, T. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70151-8 · Cited by 850
Global longitudinal strain: a novel index of left ventricular systolic function
Reisner, S. A., Lysyansky, P., Agmon, Y., Mutlak, D., Lessick, J., & Friedman, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.02.011 · Cited by 735
HL7 FHIR: An Agile and RESTful approach to healthcare information exchange
Bender, D., & Sartipi, K. (2013) · Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2013.6627810 · Cited by 540
Langeland, S., D’hooge, J., Wouters, P. F., Leather, H. A., Claus, P., Bijnens, B., & Sutherland, G. R. (2005) · Circulation · doi:10.1161/circulationaha.105.554006 · Cited by 331
The Functional Anatomy of Ventricular Contraction
RUSHMER, R. F., CRYSTAL, D. K., & WAGNER, C. (1953) · Circulation Research · doi:10.1161/01.res.1.2.162 · Cited by 328
In vivo quantitative ultrasonic evaluation of myocardial fibrosis in humans.
Picano, E., Pelosi, G., Marzilli, M., Lattanzi, F., Benassi, A., Landini, L., & L'Abbate, A. (1990) · Circulation · doi:10.1161/01.cir.81.1.58 · Cited by 231
Becker, M., Bilke, E., Kühl, H., Katoh, M., Kramann, R., Franke, A., Bücker, A., Hanrath, P., & Hoffmann, R. (2006) · Heart · doi:10.1136/hrt.2005.077107 · Cited by 222
Cited by
Rajkomar, A., Dean, J., & Kohane, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1814259 · Cited by 4,579
Self-citationKey challenges for delivering clinical impact with artificial intelligence
Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1426-2 · Cited by 3,136
Artificial intelligence in healthcare
Yu, K.-H., Beam, A. L., & Kohane, I. S. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0305-z · Cited by 2,817
Self-citationScalable and accurate deep learning with electronic health records
Rajkomar, A., Oren, E., Chen, K., Dai, A. M., Hajaj, N., Hardt, M., Liu, P. J., Liu, X., Marcus, J., Sun, M., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0029-1 · Cited by 2,648
Acosta, J. N., Falcone, G. J., Rajpurkar, P., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-022-01981-2 · Cited by 1,365
Metadata
- Authors
- Mandel, J. C., Kreda, D. A., Mandl, K. D., Kohane, I. S., & Ramoni, R. B.
- Affiliations
- Harvard University (US)
- Corresponding author
- Mandel, Joshua C
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-02-17
- Volume
- 23
- Issue
- 5
- Pages
- 899-908
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC4997036
- OpenAlex
- W2276530525
- Cited by
- 829
- References
- 28
- Citations by year
- 2026: 153 · 2025: 96 · 2024: 72 · 2023: 64 · 2022: 87 · 2021: 97 · 2020: 72 · 2019: 82 · 2018: 44 · 2017: 45 · 2016: 17
- FWCI
- 106.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of the American Medical Informatics Association (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Nursing › Research and Theory › Nursing Diagnosis and Documentation
- Health Sciences › Health Professions › Health Information Management › Medical Coding and Health Information
- Keywords
- SMART on FHIR, FHIR, electronic health records, healthcare interoperability, clinical data model, Health Level Seven, application programming interfaces, medical terminology
- MeSH terms
- Health Information Interoperability, Software, History, 21st Century, Health Level Seven, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SMART on FHIR: a standards-based, interoperable apps platform for electronic health records. https://app.cochat.ai/papers/10.1093/jamia/ocv189
- The paper
- Mandel, J. C., Kreda, D. A., Mandl, K. D., Kohane, I. S., & Ramoni, R. B. (2016). SMART on FHIR: a standards-based, interoperable apps platform for electronic health records. Journal of the American Medical Informatics Association. https://doi.org/10.1093/jamia/ocv189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.