CoChat

Reducing drug prescription errors and adverse drug events by application of a probabilistic, machine-learning based clinical decision support system in an inpatient setting

Open access
Segal, G, Segev, A, Brom, A, Lifshitz, Y, Wasserstrum, Y, Zimlichman, E · 2019 · Journal of the American Medical Informatics Association
Cited by 110

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Drug prescription errors are made, worldwide, on a daily basis, resulting in a high burden of morbidity and mortality. Existing rule-based systems for prevention of such errors are unsuccessful and associated with substantial burden of false alerts. Objective: In this prospective study, we evaluated the accuracy, validity, and clinical usefulness of medication error alerts generated by a novel system using outlier detection screening algorithms, used on top of a legacy standard system, in a real-life inpatient setting. Materials and Methods: We integrated a novel outlier system into an existing electronic medical record system, in a single medical ward in a tertiary medical center. The system monitored all drug prescriptions written during 16 months. The department’s staff assessed all alerts for accuracy, clinical validity, and usefulness. We recorded all physician’s real-time responses to alerts generated. Results: The alert burden generated by the system was low, with alerts generated for 0.4% of all medication orders. Sixty percent of the alerts were flagged after the medication was already dispensed following changes in patients’ status which necessitated medication changes (eg, changes in vital signs). Eighty-five percent of the alerts were confirmed clinically valid, and 80% were considered clinically useful. Forty-three percent of the alerts caused changes in subsequent medical orders. Conclusion: A clinical decision support system that used a probabilistic, machine-learning approach based on statistically derived outliers to detect medication errors generated clinically useful alerts. The system had high accuracy, low alert burden and low false-positive rate, and led to changes in subsequent orders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jamia/ocz135

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
Segal, G., Segev, A., Brom, A., Lifshitz, Y., Wasserstrum, Y., & Zimlichman, E.
Venue
Journal of the American Medical Informatics Association
Published
2019-08-07
Volume
26
Issue
12
Pages
1560-1565
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2966194224
Cited by
110
References
6
FWCI
9.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.