The DOI matches its Crossref record.
More Powerful Peroxide Kjeldahl Digestion Method
Abstract
Enhanced ammonia recovery and a simplified method are described for a rapid Kjeldahl digestion using sulfuric acid and hydrogen peroxide as the sole digestion reagents. This micro procedure uses a Vigreux fractionating head fitted to a 100 mL volumetric flask and a hot plate with a solid-state controller. Continuous-flow peroxide addition is controlled by a capillary funnel, and fumes are evacuated through a side-arm vent leading to a water aspirator. Complete recovery of nitrogen from the refractory compound, nicotinic acid, is obtained with less than 10 min digestion. The described method reduces digestion time by 25-50% over the open-manifold peroxy method. A digestibility index (DI), scaled 0-10, establishes the difficulty of digestion for each sample and assigns values to compounds. A useful tool for determining the minimal amount of reagent and digestion time required, the DI assigns zero for compounds not needing digestion and 10 for nicotinic acid. Digested samples obtained from the described method are suitable for direct colorimetric analysis of many elements in addition to Kjeldahl nitrogen. Distillation of the digested sample is not required
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sáez-Plaza, P., Navas, M. J., Wybraniec, S., Michałowski, T., & Asuero, A. G. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751787 · Cited by 523
Lourenço, S. O., Barbarino, E., Lavín, P. L., Lanfer Marquez, U. M., & Aidar, E. (2004) · European Journal of Phycology · doi:10.1080/0967026032000157156 · Cited by 507
Lourenco, S. O., Barbarino, E., De-Paula, J. C., Pereira, L. O. D. S., & Marquez, U. M. L. (2002) · Phycological Research · doi:10.1111/j.1440-1835.2002.tb00156.x · Cited by 476
“nitrogen analysis, carried out by Kjeldahl’s method (AOAC 1990) or Hach techniques (Hach et al. 1987), is fast and inexpensive.”
MethodSáez-Plaza, P., Michałowski, T., Navas, M. J., Asuero, A. G., & Wybraniec, S. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751786 · Cited by 358
Oba, M., & Allen, M. S. (2000) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(00)75000-4 · Cited by 234
Metadata
- Authors
- Hach, C. C., Bowden, B. K., Kopelove, A. B., & Brayton, S. V.
- Venue
- Journal of AOAC INTERNATIONAL
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-09-01
- Volume
- 70
- Issue
- 5
- Pages
- 783-787
- ISSN
- 0004-5756 (ISSN-L)
- OpenAlex
- W2475112939
- Cited by
- 159
- References
- 0
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: More Powerful Peroxide Kjeldahl Digestion Method. https://app.cochat.ai/papers/10.1093/jaoac/70.5.783
- The paper
- Hach, C. C., Bowden, B. K., Kopelove, A. B., & Brayton, S. V. (1987). More Powerful Peroxide Kjeldahl Digestion Method. Journal of AOAC INTERNATIONAL. https://doi.org/10.1093/jaoac/70.5.783
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.