Fluorometric HPLC Determination of Δ-Aminolevulinic Acid (ALA) in the Plasma and Urine of Lead Workers: Biological Indicators of Lead Exposure
Open accessThe DOI matches its Crossref record.
Abstract
A fluorometric high-performance liquid chromatographic (HPLC) method was developed for the highly sensitive measurement of delta-aminolevulinic acid (ALA) in biological materials. By using this method, we determined ALA in the plasma and urine of 418 workers occupationally exposed to lead and in the plasma and urine of 227 controls. The concentrations of ALA in the plasma and urine of lead workers were significantly elevated as compared with those of the controls. The concentration of ALA in plasma and urine was highly correlated with that of lead in blood in lead workers. It was found that the correlation (r = 0.742) between log of plasma ALA concentrations and blood lead concentrations in lead workers was similar to that (r = 0.711) between log of urine ALA concentrations and blood lead concentrations. These results demonstrated that the measurement of ALA in plasma or in urine using a fluorometric HPLC method was useful for the biological monitoring of lead workers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Döring, F., Walter, J., Will, J., Föcking, M., Boll, M., Amasheh, S., Clauss, W., & Daniel, H. (1998) · Journal of Clinical Investigation · doi:10.1172/jci1909 · Cited by 269
5‐Aminolevulinic Acid Derivatives in Photomedicine: Characteristics, Application and Perspectives
Fotinos, N., Campo, M. A., Popowycz, F., Gurny, R., & Lange, N. (2006) · Photochemistry and Photobiology · doi:10.1562/2006-02-03-ir-794 · Cited by 238
“uptake, this study directly quantified the active compound by means of precolumn derivatization fluorescence HPLC (69,70).”
MethodFang, Y.-P., Tsai, Y.-H., Wu, P.-C., & Huang, Y.-B. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.01.020 · Cited by 195
De Rosa, F. S., Marchetti, J. M., Thomazini, J. A., Tedesco, A. C., & Bentley, M. V. L. B. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00213-8 · Cited by 131
Evaluation of the penetration of 5‐aminolevulinic acid through basal cell carcinoma: a pilot study
Ahmadi, S., McCarron, P. A., Donnelly, R. F., Woolfson, A. D., & McKenna, K. (2004) · Experimental Dermatology · doi:10.1111/j.0906-6705.2004.00181.x · Cited by 55
Topical Bioadhesive Patch Systems Enhance Selectivity of Protoporphyrin IX Accumulation
Donnelly, R. F., Ma, L., Juzenas, P., Lani, V., McCarron, P. A., Woolfson, A. D., & Moan, J. (2006) · Photochemistry and Photobiology · doi:10.1562/2005-08-08-ra-641 · Cited by 22
Metadata
- Authors
- Oishi, H., Nomiyama, H., Nomiyama, K., & Tomokuni, K.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-03-01
- Volume
- 20
- Issue
- 2
- Pages
- 106-110
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2128171069
- Cited by
- 75
- References
- 0
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.