CoChat

The Effects of Collection Methods On Oral Fluid Codeine Concentrations

O'Neal, C. L., Crouch, D. J., Rollins, D. E., Fatah, A. A. · 2000 · Journal of Analytical Toxicology
Cited by 86

The DOI matches its Crossref record.

Abstract

The use of a variety of alternative biological specimens such as oral fluid for the detection and quantitation of drugs has recently been the focus of considerable scientific research and evaluation. A disadvantage of drug testing using alternative specimens is the lack of scientific literature describing the collection and analyses of these specimens and the limited literature about the pharmacokinetics and disposition of drugs in the specimen. Common methods of oral fluid collection are spitting, draining, suction, and collection on various types of absorbent swabs. The effect(s) of collection techniques on the resultant oral fluid drug concentration has not been thoroughly evaluated. Reported is a controlled clinical study (using codeine) that was designed to determine the effects of five collection techniques and devices on oral fluid codeine concentrations. The collection techniques were control (spitting), acidic stimulation, nonacidic stimulation, and use of either the Salivette or the Finger Collector (containing Accu-Sorb) oral fluid collection devices. Preliminary data were collected from two subjects using the Orasure device. The in vitro drug recovery was also evaluated for the Salivette and the Finger Collector devices. With the exception of a single time point, codeine concentrations in specimens collected by the control method (spitting) were consistently higher than concentrations in specimens collected by the other methods. The control collection concentrations averaged 3.6 times higher than concentrations in specimens collected by acidic stimulation and 1.3 to 2.0 higher than concentrations in specimens collected by nonacidic stimulation or collection using either the Salivette or the Finger Collector devices. When calculated using oral fluid codeine concentrations from the clinical study, the elimination rate constant, t(1/2), AUC and the peak oral fluid concentrations demonstrated device differences. The slope of the elimination curve for codeine using the acidic collection method exceeded that of the other four methods. As a result, the t(1/2) for the acidic method was significantly less than that of the control method (1.8 vs. 3.0 h, respectively). Oral contamination contributed to the control method having higher AUC than that calculated using the other methods. There was considerable variation in peak codeine concentrations between devices and between individuals within each collection method. When samples were collected simultaneously with the Salivette and the Finger Collector, the mean codeine concentrations were similar. We were able to recover > or = 500 microL of oral fluid from 81.8% of the clinical samples collected with the Salivette. However, we were able to recover this volume from only 25.5% of the samples collected with the Finger Collector. In addition, the in vitro drug recoveries were lower using the Finger Collector. When oral fluid was collected nearly simultaneously by the control method and by use of the Salivette, mean control codeine concentrations were 2.3 times higher, but the duration of detection was similar for both methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/24.7.536

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 86

Metadata

Authors
O'Neal, C. L., Crouch, D. J., Rollins, D. E., & Fatah, A. A.
Venue
Journal of Analytical Toxicology
Published
2000-10-01
Volume
24
Issue
7
Pages
536-542
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2135434933
Cited by
86
References
0
FWCI
3.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effects of Collection Methods On Oral Fluid Codeine Concentrations. https://app.cochat.ai/papers/10.1093/jat/24.7.536
The paper
O'Neal, C. L., Crouch, D. J., Rollins, D. E., & Fatah, A. A. (2000). The Effects of Collection Methods On Oral Fluid Codeine Concentrations. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/24.7.536

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.