CoChat

Assay of 9-Tetrahydrocannabinol (THC) in Oral Fluid--Evaluation of the OraSure Oral Specimen Collection Device

Kauert, G. F., Iwersen-Bergmann, S., Toennes, S. W. · 2006 · Journal of Analytical Toxicology
Cited by 56

The DOI matches its Crossref record.

Abstract

Oral fluid is considered to be an alternative to urine testing for the detection of acute ingestion of drugs. The OraSure Intercept DOA Oral Specimen Collection Device (OSCD) has been used in studies for the quantitation of Delta9-tetrahydrocannabinol (THC), but concerns have been raised. In the present study, we investigated whether the volume of oral fluid can be determined and how much THC remains adsorbed on the device. It was found that THC is markedly adsorbed onto the absorptive pad. The recovery using the standard elution procedure was only 37.8 +/- 9.4% for 10 ng/mL and 55.6 +/- 1.0% for 100 ng/mL of THC in oral fluid (n = 5 each). With an additional methanol wash, a further 25% could be eluted. Therefore, a modification of the procedure was evaluated, consisting of the addition of 2 mL of methanol to the elution buffer. THC could be completely recovered over a range of concentrations (1 to 1000 ng/mL). For the determination of the amount of oral fluid absorbed, a gravimetric approach was evaluated as the weights of the devices vary only by 0.6% relative standard deviation. After application of 0.5 mL oral fluid to pads and evaluation of the weight differences, the applied amount could be estimated with a precision of 7.5% (n = 8) and an accuracy of 6.1%. From these results it can be concluded that the OraSure OSCD is useful to collect oral fluid for reliable quantitative THC assay applying a modified elution procedure and gravimetric determination of the amount of oral fluid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/30.4.274

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 56

Metadata

Authors
Kauert, G. F., Iwersen-Bergmann, S., & Toennes, S. W.
Venue
Journal of Analytical Toxicology
Published
2006-05-01
Volume
30
Issue
4
Pages
274-277
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2109658904
Cited by
56
References
0
FWCI
7.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assay of 9-Tetrahydrocannabinol (THC) in Oral Fluid--Evaluation of the OraSure Oral Specimen Collection Device. https://app.cochat.ai/papers/10.1093/jat/30.4.274
The paper
Kauert, G. F., Iwersen-Bergmann, S., & Toennes, S. W. (2006). Assay of 9-Tetrahydrocannabinol (THC) in Oral Fluid--Evaluation of the OraSure Oral Specimen Collection Device. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/30.4.274

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.