CoChat

Metabolites of Heroin in Several Different Post-mortem Matrices

Open access

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

In some forensic autopsies blood is not available, and other matrices are sampled for toxicological analysis. The aims of the present study were to examine whether heroin metabolites can be detected in different post-mortem matrices, and investigate whether analyses in other matrices can give useful information about concentrations in peripheral blood. Effects of ethanol on the metabolism and distribution of heroin metabolites were also investigated. We included 45 forensic autopsies where morphine was detected in peripheral blood, concomitantly with 6-acetylmorphine (6-AM) detected in any matrix. Samples were collected from peripheral blood, cardiac blood, pericardial fluid, psoas muscle, lateral vastus muscle, vitreous humor and urine. Opioid analysis included 6-AM, morphine, codeine, and morphine glucuronides. The 6-AM was most often detected in urine (n = 39) and vitreous humor (n = 38). The median morphine concentration ratio relative to peripheral blood was 1.3 (range 0-3.6) for cardiac blood, 1.4 (range 0.07-5.3) for pericardial fluid, 1.2 (range 0-19.2) for psoas muscle, 1.1 (range 0-1.7) for lateral vastus muscle and 0.4 (range 0.2-3.2) for vitreous humor. The number of 6-AM positive cases was significantly higher (P = 0.03) in the ethanol positive group (n = 6; 86%) compared to the ethanol negative group (n = 14; 37%) in peripheral blood. The distribution of heroin metabolites to the different matrices was not significantly different between the ethanol positive and the ethanol negative group. This study shows that toxicological analyses of several matrices could be useful in heroin-related deaths. Urine and vitreous humor are superior for detection of 6-AM, while concentrations of morphine could be assessed from peripheral or cardiac blood, pericardial fluid, psoas muscle and lateral vastus muscle.

Overview

Integrity signals

Registry

Crossref · 10.1093/jat/bky002

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 45 references

Cited by

See all 30

Metadata

Authors
Thaulow, C. H., Øiestad, Å. M. L., Rogde, S., Karinen, R., Brochmann, G. W., Andersen, J. M., Høiseth, G., Handal, M., Mørland, J., Arnestad, M., Øiestad, E. L., Strand, D. H., & Vindenes, V.
Affiliations
  • Oslo University Hospital (NO)
  • Norwegian Institute of Public Health (NO)
Corresponding author
Thaulow, Cecilie Hasselø
Venue
Journal of Analytical Toxicology
Published
2018-02-02
Volume
42
Issue
5
Pages
311-320
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2789381831
Cited by
27
References
45
Citations by year
2025: 5 · 2023: 4 · 2022: 2 · 2021: 6 · 2020: 5 · 2019: 3 · 2018: 2
FWCI
3.34
Type
journal article
Language
en
Open access
Locations
  • Journal of Analytical Toxicology (publishedVersion)
  • PubMed (publishedVersion)
  • NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Opioid Use Disorder Treatment
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Autopsy Techniques and Outcomes
Keywords
heroin, heroin metabolites, 6-monoacetylmorphine, morphine, postmortem toxicology, vitreous humor, urine, cardiac blood, pericardial fluid, muscle tissue, ethanol, heroin-related deaths
MeSH terms
Pericardial Fluid, Alcohol Drinking, Cadaver, Codeine, Heroin, Humans, Morphine, Morphine Derivatives, Opioid-Related Disorders, Narcotics, Norway, Tissue Distribution, Vitreous Body, Substance Abuse Detection, Psoas Muscles, Glucuronides, Quadriceps Muscle, Forensic Toxicology, Toxicokinetics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metabolites of Heroin in Several Different Post-mortem Matrices. https://app.cochat.ai/papers/10.1093/jat/bky002
The paper
Thaulow, C. H., Øiestad, Å. M. L., Rogde, S., Karinen, R., Brochmann, G. W., Andersen, J. M., Høiseth, G., Handal, M., Mørland, J., Arnestad, M., Øiestad, E. L., Strand, D. H., & Vindenes, V. (2018). Metabolites of Heroin in Several Different Post-mortem Matrices. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bky002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.