CoChat

Analysis of Fentanyl and 18 Novel Fentanyl Analogs and Metabolites by LC–MS-MS, and report of Fatalities Associated with Methoxyacetylfentanyl and Cyclopropylfentanyl

Fogarty, Melissa F, Papsun, Donna M, Logan, Barry K · 2018 · Journal of Analytical Toxicology
Cited by 136

The DOI matches its Crossref record.

Abstract

Methoxyacetylfentanyl and cyclopropylfentanyl are two of the newest illicit opioids that are infiltrating the heroin market. Methoxyacetylfentanyl and cyclopropylfentanyl were reported by the Drug Enforcement Administration (DEA) in their third quarter report of 2017 to have been chemically identified seven and five times, respectively, from drug evidence analyzed by the DEA's lab system; Q3 was the first time cyclopropylfentanyl was identified by the DEA's lab system, while methoxyacetylfentanyl was reported one time in Q2 2017. A method was developed using liquid chromatography tandem mass spectrometry for the quantitation of fentanyl, norfentanyl and 17 fentanyl analogs: furanylfentanyl, butyrylfentanyl, despropionylfentanyl (4-ANPP), methoxyacetylfentanyl, tetrahydrofuran fentanyl, fluoro-isobutyrylfentanyl, acrylfentanyl, para-fluorofentanyl, ortho-fluorofentanyl, carfentanil, beta-methylfentanyl, isobutyrylfentanyl, para-methylfentanyl, cyclopentylfentanyl, cyclopropylfentanyl, beta-hydroxyfentanyl and alpha-methylfentanyl. The calibration range for all compounds was 0.1-100 ng/mL. Blood samples from 42 postmortem cases involving cyclopropylfentanyl and methoxyacetylfentanyl from Florida, Illinois, Michigan and Tennessee were submitted for toxicological analysis. The mean and median concentration for the cases testing positive for cyclopropylfentanyl (n = 32) was 15.3 (±11.9) ng/mL and 12.3 ng/mL, respectively, with a range of 1.4-43.3 ng/mL. The mean (±SD) and median concentrations for the 11 cases quantitatively confirmed (3 cases were below the limit of quantitation) for methoxyacetylfentanyl was 17.7 (±11.4) ng/mL and 15.1 ng/mL respectively, with a range of 0.21-39.9 ng/mL. These novel illicit substances typically are outside the scope of routine drug testing by hospitals and toxicology laboratories or below the sensitivity levels for the detection of these substances in biological specimens. These compounds have not previously been studied in humans; therefore, it is significant to be able to associate the pharmacological effects derived from case reports to the quantitative values found in the postmortem specimens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jat/bky035

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 136

Metadata

Authors
Fogarty, M. F., Papsun, D. M., & Logan, B. K.
Venue
Journal of Analytical Toxicology
Published
2018-05-10
Volume
42
Issue
9
Pages
592-604
ISSN
  • 0146-4760 (ISSN-L)
  • 1945-2403
OpenAlex
W2802463390
Cited by
136
References
0
FWCI
49.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of Fentanyl and 18 Novel Fentanyl Analogs and Metabolites by LC–MS-MS, and report of Fatalities Associated with Methoxyacetylfentanyl and Cyclopropylfentanyl. https://app.cochat.ai/papers/10.1093/jat/bky035
The paper
Fogarty, M. F., Papsun, D. M., & Logan, B. K. (2018). Analysis of Fentanyl and 18 Novel Fentanyl Analogs and Metabolites by LC–MS-MS, and report of Fatalities Associated with Methoxyacetylfentanyl and Cyclopropylfentanyl. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bky035

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.