HighResNPS.com: An Online Crowd-Sourced HR-MS Database for Suspect and Non-targeted Screening of New Psychoactive Substances
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The number of new psychoactive substances (NPS) is constantly increasing. However, although the number might be large, most NPS have a low prevalence of use, so keeping screening libraries updated with the relevant analytical targets becomes a challenge. One way to ensure sufficient screening coverage is to use shared high resolution-mass spectrometry (HR-MS) databases, such as HighResNPS.com: a free, online, spreadsheet-format, crowd-sourced HR-MS database for NPS screening. The aims of this study were (i) to present the database to the scientific community and (ii) to verify that the HighResNPS database can be utilized in suspect screening workflows for LC–HR-MS instruments and software from four different instrument vendors. A sample was spiked with 10 NPS, and participating laboratories then analyzed the sample with their respective HR-MS vendor platforms and the HighResNPS database. The HighResNPS data were obtained via a spreadsheet converted to fit the import specifications of the different vendor platforms. Suspect screening was performed using LC–HR-MS vendor platforms from Thermo Fisher, Waters, Bruker and Agilent. All 10 NPS were identified in at least three workflows used for the four different vendor platforms. Multiple users have submitted data to HighResNPS for the same NPS, which resulted in multiple true-positive identifications for these NPS. Suspect screening with LC–HR-MS can be based on diagnostic fragment ions reported by users of different vendor platforms and can support NPS identification in biological samples and/or seizure analyses when no reference standard is available in-house. The present work clearly demonstrates that HighResNPS data is compatible with instruments and screening software from at least four different vendor platforms. The database can thus serve as a useful add-on in LC–HR-MS screening workflows.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HMDB 4.0: the human metabolome database for 2018
Wishart, D. S., Feunang, Y. D., Marcu, A., Guo, A. C., Liang, K., Vázquez-Fresno, R., Sajed, T., Johnson, D., Li, C., Karu, N., et al. (2018) · Nucleic Acids Research · doi:10.1093/nar/gkx1089 · Cited by 3,438
MassBank: a public repository for sharing mass spectral data for life sciences
Horai, H., Arita, M., Kanaya, S., Nihei, Y., Ikeda, T., Suwa, K., Ojima, Y., Tanaka, K., Tanaka, S., Aoshima, K., et al. (2010) · Journal of Mass Spectrometry · doi:10.1002/jms.1777 · Cited by 2,529
Cited by
First Report on Brorphine: The Next Opioid on the Deadly New Psychoactive Substance Horizon?
Verougstraete, N., Vandeputte, M. M., Lyphout, C., Cannaert, A., Hulpia, F., Van Calenbergh, S., Verstraete, A. G., & Stove, C. (2021) · Journal of Analytical Toxicology · doi:10.1093/jat/bkaa094 · Cited by 44
“25 ppm), assigned to single-protonated [M+H] brorphine (C20H23BrN3O) in the HighResNPS library (26) and reported by Kennedy et al.”
BackgroundVandeputte, M. M., Verougstraete, N., Walther, D., Glatfelter, G. C., Malfliet, J., Baumann, M. H., Verstraete, A. G., & Stove, C. P. (2022) · Archives of Toxicology · doi:10.1007/s00204-022-03294-2 · Cited by 44
Nitazene test strips: a laboratory evaluation
De Vrieze, L. M., Stove, C. P., & Vandeputte, M. M. (2024) · Harm Reduction Journal · doi:10.1186/s12954-024-01078-8 · Cited by 34
“This purity estimate was defined as the ratio of the peak intensity of the nitazene analogue in question to the overall peak intensities of all substances detected in a given sample, using the HighResNPS library [48] with a cut-off set at 50 (data not shown).”
MethodMonti, M. C., De Vrieze, L. M., Vandeputte, M. M., Persson, M., Gréen, H., Stove, C. P., & Schlotterbeck, G. (2024) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2024.116453 · Cited by 18
Voronov, G., Lightheart, R., Frandsen, A., Bargh, B., Haynes, S. E., Spencer, E., Schoenhardt, K. E., Davidson, C., Schaum, A., Macherla, V. R., et al. (2022) · doi:10.1101/2022.10.09.511482 · Cited by 18
Activity-based detection of synthetic cannabinoid receptor agonists in plant materials
Timmerman, A., Balcaen, M., Coopman, V., Degreef, M., Pottie, E., & Stove, C. P. (2024) · Harm Reduction Journal · doi:10.1186/s12954-024-01044-4 · Cited by 8
“The HighRes NPS library [45] and a set of in-house reference standards were used to include matching based on (i) mass accuracy, (ii) retention time, (iii) isotope pattern, and (iv) MS² spectrum (number of fragment ions) in the identification procedure.”
Method
Metadata
- Authors
- Mardal, M., Andreasen, M. F., Mollerup, C. B., Stockham, P., Telving, R., Thomaidis, N. S., Diamanti, K. S., Linnet, K., & Dalsgaard, P. W.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-05-16
- Volume
- 43
- Issue
- 7
- Pages
- 520-527
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2946046238
- Cited by
- 113
- References
- 2
- FWCI
- 18.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.