Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Variability and Accuracy in Mammographic Interpretation Using the American College of Radiology Breast Imaging Reporting and Data System

Kerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., Sickles, E. A.·1998·JNCI Journal of the National Cancer Institute

Abstract

BACKGROUND: Several studies, which were limited by their small sample size and selection of difficult cases for review, have reported substantial variability among radiologists in interpretation of mammographic examinations. We have determined, in the largest study to date, intraobserver and interobserver agreement in interpreting screening mammography and accuracy of mammography by use of the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS). METHODS: The mammographic examinations were randomly selected on the basis of original mammographic interpretation and cancer outcome from 71,713 screening examinations performed by the Mobile Mammography Screening Program of the University of California, San Francisco, during the period from April 1985 through February 1995. The final sample included 786 abnormal examinations with no cancer detected, 267 abnormal examinations with cancer detected, and 1563 normal examinations. Films were read separately by two radiologists according to BI-RADS. Cancer status was determined by contacting women's physicians and by linkage to the regional Surveillance, Epidemiology, and End Results Program. RESULTS: There was moderate agreement between radiologists in reporting the presence of a finding when cancer was present (kappa = 0.54) and substantial agreement when cancer was not present (kappa = 0.62). Agreement was moderate in assigning one of the five assessment categories but was statistically significantly lower when cancer was present relative to when cancer was not present (kappa = 0.46 versus 0.56; two-sided P = .02). Agreement for reporting the presence of a finding and mammographic assessment was two-fold more likely for examinations with less dense breasts. Agreement was higher on repeat readings by the same radiologists than between radiologists. The sensitivity of mammography was lower with BI-RADS than with the original system for mammographic interpretation, but the positive predictive value of mammography was higher. CONCLUSION: Considerable variability in interpretation of mammographic examinations exists; this variability and the accuracy of mammography are neither improved nor diminished with use of BI-RADS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jnci/90.23.1801

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 298

Metadata

Authors
Kerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A.
Venue
JNCI Journal of the National Cancer Institute
Published
1998-12-02
Volume
90
Issue
23
Pages
1801-1809
ISSN
  • 0027-8874 (ISSN-L)
  • 1460-2105
OpenAlex
W2126804515
Cited by
298
References
1
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability and Accuracy in Mammographic Interpretation Using the American College of Radiology Breast Imaging Reporting and Data System. https://app.cochat.ai/papers/10.1093/jnci/90.23.1801
The paper
Kerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A. (1998). Variability and Accuracy in Mammographic Interpretation Using the American College of Radiology Breast Imaging Reporting and Data System. JNCI Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/90.23.1801

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.