Variability and Accuracy in Mammographic Interpretation Using the American College of Radiology Breast Imaging Reporting and Data System
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Several studies, which were limited by their small sample size and selection of difficult cases for review, have reported substantial variability among radiologists in interpretation of mammographic examinations. We have determined, in the largest study to date, intraobserver and interobserver agreement in interpreting screening mammography and accuracy of mammography by use of the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS). METHODS: The mammographic examinations were randomly selected on the basis of original mammographic interpretation and cancer outcome from 71,713 screening examinations performed by the Mobile Mammography Screening Program of the University of California, San Francisco, during the period from April 1985 through February 1995. The final sample included 786 abnormal examinations with no cancer detected, 267 abnormal examinations with cancer detected, and 1563 normal examinations. Films were read separately by two radiologists according to BI-RADS. Cancer status was determined by contacting women's physicians and by linkage to the regional Surveillance, Epidemiology, and End Results Program. RESULTS: There was moderate agreement between radiologists in reporting the presence of a finding when cancer was present (kappa = 0.54) and substantial agreement when cancer was not present (kappa = 0.62). Agreement was moderate in assigning one of the five assessment categories but was statistically significantly lower when cancer was present relative to when cancer was not present (kappa = 0.46 versus 0.56; two-sided P = .02). Agreement for reporting the presence of a finding and mammographic assessment was two-fold more likely for examinations with less dense breasts. Agreement was higher on repeat readings by the same radiologists than between radiologists. The sensitivity of mammography was lower with BI-RADS than with the original system for mammographic interpretation, but the positive predictive value of mammography was higher. CONCLUSION: Considerable variability in interpretation of mammographic examinations exists; this variability and the accuracy of mammography are neither improved nor diminished with use of BI-RADS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 1×
“Guidelines used for interpreting the amount of agreement were those reported by Landis and Koch ( 15 ), where k values were defined as follows: k 4 0 is poor agreement; k 4 0.01‐0.2 is slight agreement; k 4 0.21‐0.40 is fair agreement; k 4 0.41‐0.60 is moderate agreement; k 4 0.61‐0.80 is substantial agreement; and k…”
MethodInfluentialStatistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Statistical Methods for Rates and Proportions, 2nd ed
GROVE, W. A. (1981) · American Journal of Psychiatry · doi:10.1176/ajp.138.12.1644-a · Cited by 3,748
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Boyd, N. F., Byng, J. W., Jong, R. A., Fishell, E. K., Little, L. E., Miller, A. B., Lockwood, G. A., Tritchler, D. L., & Yaffe, M. J. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.9.670 · Cited by 1,105
Statistical methods for assessing observer variability in clinical measures.
Brennan, P., & Silman, A. (1992) · BMJ · doi:10.1136/bmj.304.6840.1491 · Cited by 985
Mammographic Features and Breast Cancer Risk: Effects With Time, Age, and Menopause Status
Byrne, C., Schairer, C., Wolfe, J., Parekh, N., Salane, M., Brinton, L. A., Hoover, R., & Haile, R. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.21.1622 · Cited by 864
Effect of Age, Breast Density, and Family History on the Sensitivity of First Screening Mammography
Kerlikowske, K. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540010035027 · Cited by 624
Self-citationVariability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Benefit of independent double reading in a population-based mammography screening program.
Thurfjell, E. L., Lernevall, K. A., & Taube, A. A. (1994) · Radiology · doi:10.1148/radiology.191.1.8134580 · Cited by 406
Positive Predictive Value of Screening Mammography by Age and Family History of Breast Cancer
Kerlikowske, K. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510200050031 · Cited by 364
Self-citationBeam, C. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440020119016 · Cited by 337
Baker, J. A., Kornguth, P. J., & Floyd, C. E. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.4.8610547 · Cited by 178
Sickles, E. A., Ominsky, S. H., Sollitto, R. A., Galvin, H. B., & Monticciolo, D. L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326455 · Cited by 167
Self-citationAcceptable Values of Kappa for Comparison of Two Groups
Seigel, D. G., Podgo, M. J., & Remaley, N. A. (1992) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a116324 · Cited by 159
The Impact of Clinical History on Mammographic Interpretations
Elmore, J. G. (1997) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1997.03540250057032 · Cited by 89
Mammographic screening: how to operate successfully at low cost.
Sickles, E. A., Weber, W., Galvin, H. B., Ominsky, S. H., & Sollitto, R. A. (1986) · Radiology · doi:10.1148/radiology.160.1.3715053 · Cited by 78
Self-citationInter-observer and intra-observer variability of mammogram interpretation: a field study
Ciccone, G., Vineis, P., Frigerio, A., & Segnan, N. (1992) · European Journal of Cancer · doi:10.1016/0959-8049(92)90455-b · Cited by 54
Computerized follow-up of abnormalities detected at mammography screening.
Monticciolo, D. L., & Sickles, E. A. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.4.2119104 · Cited by 26
Self-citationInter-Observer Variability in the Interpretation of Mammograms
Vineis, P., Sinistrero, G., Temporelli, A., Azzoni, L., Bigo, A., Burke, P., Ciccone, G., Fasciano, F., Ferraris, R., Frigerio, A., et al. (1988) · Tumori Journal · doi:10.1177/030089168807400306 · Cited by 23
Cited by
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.6.1741769 · Cited by 1,273
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Plon, S. E., Eccles, D. M., Easton, D., Foulkes, W. D., Genuardi, M., Greenblatt, M. S., Hogervorst, F. B. L., Hoogerbrugge, N., Spurdle, A. B., Tavtigian, S. V., et al. (2008) · Human Mutation · doi:10.1002/humu.20880 · Cited by 912
Mammographic density and breast cancer risk: current understanding and future prospects
Boyd, N. F., Martin, L. J., Yaffe, M. J., & Minkin, S. (2011) · Breast Cancer Research · doi:10.1186/bcr2942 · Cited by 609
Metadata
- Authors
- Kerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-12-02
- Volume
- 90
- Issue
- 23
- Pages
- 1801-1809
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2126804515
- Cited by
- 298
- References
- 20
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.