Axillary Lymph Node Staging in Breast Cancer by 2-Fluoro-2-deoxy-D-glucose-Positron Emission Tomography: Clinical Evaluation and Alternative Management
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Surgical removal of axillary lymph node and histologic examination for metastases are used to determine whether adjuvant treatment is necessary for patients with breast cancer. Axillary lymph node dissection (ALND) is a costly procedure associated with various side effects, and 80% or more of patients with tumors of 20 mm or less are lymph node negative and might avoid ALND. In this study, we evaluated whether an alternative, noninvasive method--i.e., positron emission tomography (PET) with 2-[(18)F]fluoro-2-deoxy-D-glucose (FDG)-- could be used to determine axillary lymph node status in patients with breast cancer. METHODS: One hundred sixty-seven consecutive patients with breast cancers of 50 mm or less (range = 5-50 mm; mean = 21 mm) scheduled for complete ALND were studied preoperatively with FDG-PET, and then PET and pathology results from ALND were compared. All statistical tests were two-sided. RESULTS: The overall sensitivity, specificity, and accuracy of lymph node staging with PET were 94.4% (PET detected 68 of 72 patients with axillary involvement; 95% confidence interval [CI] = 86.0% to 98.2%), 86.3% (82 of 95 patients without axillary involvement; 95% CI = 77.8% to 91.9%), and 89.8% (150 of 167 patients with breast cancer; 95% CI = 84.2% to 93.6%), respectively. Positive- and negative-predictive values were 84.0% (68 patients with histologically positive lymph nodes of 81 patients with positive FDG-PET scan; 95% CI = 74.2% to 90.5%) and 95.3% (82 patients with histologically negative lymph nodes of 86 patients with negative FDG-PET scan; 95% CI = 88.2% to 98.5%), respectively. When PET results for axillary metastasis were analyzed by tumor size, the diagnostic accuracy was similar for all groups (86.0%-94.2%), with higher sensitivity for tumors of 21-50 mm (98.0%) and higher specificity for tumors of 10 mm or less (87.8%), and the range was 93.5%-97.3% for negative-predictive values and 54.5%-94.1% for positive-predictive values. Among the 72 patients with axillary involvement, PET detected three or fewer metastatic lymph nodes in 27 (37.5%) patients, about 80% of whom had no clinically palpable axillary lymph nodes. CONCLUSIONS: Noninvasive FDG-PET appears to be an accurate technique to predict axillary status in patients with breast cancer and thus to identify patients who might avoid ALND. These results should be confirmed in large multicenter studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-sided confidence intervals for the single proportion: comparison of seven methods
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980430)17:8<857::aid-sim777>3.0.co;2-e · Cited by 5,107
Approximate is Better than “Exact” for Interval Estimation of Binomial Proportions
Agresti, A., & Coull, B. A. (1998) · The American Statistician · doi:10.1080/00031305.1998.10480550 · Cited by 3,223
Polychemotherapy for early breast cancer: an overview of the randomised trials
(1998) · The Lancet · doi:10.1016/s0140-6736(98)03301-7 · Cited by 2,042
The Sentinel Node in Breast Cancer — A Multicenter Validation Study
Krag, D., Weaver, D., Ashikaga, T., Moffat, F., Klimberg, V. S., Shriver, C., Feldman, S., Kusminsky, R., Gadd, M., Kuhn, J., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810013391401 · Cited by 2,018
Approximate Is Better than "Exact" for Interval Estimation of Binomial Proportions
Agresti, A., & Coull, B. A. (1998) · The American Statistician · doi:10.2307/2685469 · Cited by 972
(2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.13.979 · Cited by 893
Sentinel Lymph Node Biopsy and Axillary Dissection in Breast Cancer: Results in a Large Series
Veronesi, U., Paganelli, G., Viale, G., Galimberti, V., Luini, A., Zurrida, S., Robertson, C., Sacchini, V., Veronesi, P., Orvieto, E., et al. (1999) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/91.4.368 · Cited by 775
Meeting Highlights: International Consensus Panel on the Treatment of Primary Breast Cancer
Goldhirsch, A., Wood, W. C., Senn, H.-J., Glick, J. H., & Gelber, R. D. (1995) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/87.19.1441 · Cited by 689
Fisher, B. (1980) · PubMed · Cited by 441
Wahl, R. L., Cody, R. L., Hutchins, G. D., & Mudgett, E. E. (1991) · Radiology · doi:10.1148/radiology.179.3.2027989 · Cited by 431
Evaluation of breast masses and axillary lymph nodes with [F-18] 2-deoxy-2-fluoro-D-glucose PET.
Adler, L. P., Crowe, J. P., al-Kaisi, N. K., & Sunshine, J. L. (1993) · Radiology · doi:10.1148/radiology.187.3.8497624 · Cited by 372
Orr, R. K. (1999) · Annals of Surgical Oncology · doi:10.1007/s10434-999-0109-1 · Cited by 343
Sentinel-Lymph-Node Biopsy for Breast Cancer — Not Yet the Standard of Care
McMasters, K. M., Giuliano, A. E., Ross, M. I., Reintgen, D. S., Hunt, K. K., Byrd, D. R., Klimberg, V. S., Whitworth, P. W., Tafra, L. C., & Edwards, M. J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810013391410 · Cited by 299
Cancer Detection with Whole-Body PET Using 2-[18F]Fluoro-2-Deoxy-D-Glucose
Hoh, C. K., Hawkins, R. A., Glaspy, J. A., Dahlbom, M. L., Tse, N., Hoffman, E. J., Schiepers, C. W., Choi, Y. H., Rege, S., Nitzsche, E. U., et al. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00012 · Cited by 254
Validating Risk-Adjusted Surgical Outcomes: Site Visit Assessment of Process and Structure1
Daley, J., Forbes, M. G., Young, G. J., Charns, M. P., Gibbs, J. O., Hur, K., Henderson, W., & Khuri, S. F. (1997) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(01)00940-1 · Cited by 235
Oshida, M., Uno, K., Suzuki, M., Nagashima, T., Hashimoto, H., Yagata, H., Shishikura, T., Imazeki, K., & Nakajima, N. (1998) · Cancer · doi:10.1002/(sici)1097-0142(19980601)82:11<2227::aid-cncr18>3.0.co;2-w · Cited by 230
Nieweg, O. E., Kim, E. E., Wong, W.-H., Broussard, W. F., Singletary, S. E., Hortobagyi, G. N., & Tilbury, R. S. (1993) · Cancer · doi:10.1002/1097-0142(19930615)71:12<3920::aid-cncr2820711220>3.0.co;2-n · Cited by 223
Avril, N., Dose, J., Janicke, F., Ziegler, S., Romer, W., Weber, W., Herz, M., Nathrath, W., Graeff, H., & Schwaiger, M. (1996) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/88.17.1204 · Cited by 213
Wahl, R. L., Henry, C. A., & Ethier, S. P. (1992) · Radiology · doi:10.1148/radiology.183.3.1584912 · Cited by 206
TSE, N. Y., HOH, C. K., HAWKINS, R. A., ZINNER, M. J., DAHLBOM, M., CHOI, Y., MADDAHI, J., BRUNICARDI, F. C., PHELPS, M. E., & GLASPY, J. A. (1992) · Annals of Surgery · doi:10.1097/00000658-199207000-00005 · Cited by 180
Axillary lymph node metastases: screening with [F-18]2-deoxy-2-fluoro-D-glucose (FDG) PET.
Adler, L. P., Faulhaber, P. F., Schnur, K. C., Al-Kasi, N. L., & Shenk, R. R. (1997) · Radiology · doi:10.1148/radiology.203.2.9114082 · Cited by 177
Prospective evaluation of fluorine-18-FDG PET in presurgical staging of the axilla in breast cancer.
Crippa, F., Agresti, R., Seregni, E. C., Greco, M., Pascali, C., Bogni, A., Chiesa, C., Sanctis, V. D., Delledonne, V., Salvadori, B., et al. (1998) · PubMed · Cited by 161
Self-citationSmith, I. C., Ogston, K. N., Whitford, P., Smith, F. W., Sharp, P., Norton, M. Y., Miller, I. D., Ah-See, A. K., Heys, S. D., Jibril, J. A., et al. (1998) · Annals of Surgery · doi:10.1097/00000658-199808000-00012 · Cited by 140
Flanagan, F. L., Dehdashti, F., & Siegel, B. A. (1998) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(98)80034-2 · Cited by 112
Lymphatic mapping and sentinel node biopsy in breast cancer
McIntosh, S., & Purushotham, A. D. (1998) · British journal of surgery · doi:10.1046/j.1365-2168.1998.00934.x · Cited by 106
Sentinel node biopsy in the staging of breast cancer
Snider, H. C., Dowlatshahi, K., Fan, M., et al. (1998) · The American Journal of Surgery · doi:10.1016/s0002-9610(98)00207-4 · Cited by 74
A brief history of positron emission tomography (PET)
Wagner, H. N. (1998) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(98)80027-5 · Cited by 69
Crippa, F., Gavazzi, C., Bozzetti, F., Chiesa, C., Pascali, C., Bogni, A., Sanctis, V. D., Decise, D., Schiavini, M., Cucchetti, G., et al. (1997) · Tumori Journal · doi:10.1177/030089169708300407 · Cited by 60
Self-citationDiagnostic Value of Positron Emission Tomography for Detecting Breast Cancer
Noh, D., Yun, I. J., Kim, J., Kang, H., Lee, D., Chung, J., Lee, M. C., Youn, Y., Oh, S. K., & Choe, K. J. (1998) · World Journal of Surgery · doi:10.1007/s002689900374 · Cited by 59
Cited by
Progress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development
Kelloff, G. J., Hoffman, J. M., Johnson, B., Scher, H. I., Siegel, B. A., Cheng, E. Y., Cheson, B. D., O'Shaughnessy, J., Guyton, K. Z., Mankoff, D. A., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2626 · Cited by 671
18F-FDG PET/CT Imaging In Oncology
Almuhaideb, A., Papathanasiou, N., & Bomanji, J. (2011) · Annals of Saudi Medicine · doi:10.4103/0256-4947.75771 · Cited by 388
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
Wahl, R. L., Siegel, B. A., Coleman, R. E., & Gatsonis, C. G. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.04.148 · Cited by 345
The use of “overall accuracy” to evaluate the validity of screening or diagnostic tests
Alberg, A. J., Park, J. W., Hager, B. W., Brock, M. V., & Diener-West, M. (2004) · Journal of General Internal Medicine · doi:10.1111/j.1525-1497.2004.30091.x · Cited by 295
Metadata
- Authors
- Greco, M., Crippa, F., Agresti, R., Seregni, E., Gerali, A., Giovanazzi, R., Micheli, A., Asero, S., Ferraris, C., Gennaro, M., Bombardieri, E., & Cascinelli, N.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-04-18
- Volume
- 93
- Issue
- 8
- Pages
- 630-635
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2129353625
- Cited by
- 164
- References
- 29
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.