The DOI matches its Crossref record.
Association of Volume and Volume-Independent Factors With Accuracy in Screening Mammogram Interpretation
Open accessAbstract
BACKGROUND: Early detection of breast cancer is associated with the accurate reading of screening mammograms, but factors that influence reading accuracy are not well understood. We thus investigated whether reading volume and other factors were independently associated with accuracy in reading screening mammograms in a population of U.S. radiologists. METHODS: A random selection of 110 of 292 radiologists who agreed to participate, if selected, interpreted screening mammograms from 148 randomly selected women. Original index mammograms (i.e., mediolateral oblique and craniocaudal views of each breast) were used; comparison original mammograms were provided when available. Radiologist-level and facility-level factors were surveyed. Two standard metrics of screening accuracy, both based on receiver operating characteristic curves, were analyzed. The influence of volume on accuracy after controlling for other factors was assessed with multiple regression analysis. RESULTS: Current reading volume was not statistically significantly associated with interpretive accuracy. More recently trained radiologists interpreted mammograms more accurately than those trained earlier (-0.76% [95% confidence interval (CI) = -1.75% to -0.02%] reduction in sensitivity per year since residency). Facility-level factors that were statistically significantly and independently associated with better accuracy were the number of diagnostic breast imaging examinations and image-guided breast interventional procedures performed (0.55% [95% CI = 0.11% to 2.40%] increase in accuracy per examination or procedure offered), being classified as a comprehensive breast diagnostic and/or screening center or freestanding mammography center (1.39% [95% CI = 0.15% to 3.82%] higher than a hospital radiology department or multispecialty medical clinic), and being a facility that practiced double reading (1.61% [95% CI = 1.99% to 11.65%]) higher than in a facility without such practice). CONCLUSIONS: Individual radiologists' current reading volume was not statistically significantly associated with accuracy in reading screening mammograms, but several other factors were. Expertise reflects a complex multifactorial process that needs further clarification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ericsson, K. A. (2004) · Academic Medicine · doi:10.1097/00001888-200410001-00022 · Cited by 2,988
Colonoscopic Withdrawal Times and Adenoma Detection during Screening Colonoscopy
Barclay, R. L., Vicari, J. J., Doughty, A. S., Johanson, J. F., & Greenlaw, R. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa055498 · Cited by 1,313
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Kuhl, C. (2007) · Radiology · doi:10.1148/radiol.2442051620 · Cited by 778
Current perspectives in medical image perception
Krupinski, E. A. (2010) · Attention, Perception & Psychophysics · doi:10.3758/app.72.5.1205 · Cited by 343
Metadata
- Authors
- Beam, C. A., Conant, E. F., & Sickles, E. A.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-02-19
- Volume
- 95
- Issue
- 4
- Pages
- 282-290
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2096500778
- Cited by
- 158
- References
- 0
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Association of Volume and Volume-Independent Factors With Accuracy in Screening Mammogram Interpretation. https://app.cochat.ai/papers/10.1093/jnci/95.4.282
- The paper
- Beam, C. A., Conant, E. F., & Sickles, E. A. (2003). Association of Volume and Volume-Independent Factors With Accuracy in Screening Mammogram Interpretation. JNCI Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/95.4.282
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.