CoChat

Association of Volume and Volume-Independent Factors With Accuracy in Screening Mammogram Interpretation

Open access
Beam, C. A., Conant, E. F., Sickles, E. A. · 2003 · JNCI Journal of the National Cancer Institute
Cited by 158

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Early detection of breast cancer is associated with the accurate reading of screening mammograms, but factors that influence reading accuracy are not well understood. We thus investigated whether reading volume and other factors were independently associated with accuracy in reading screening mammograms in a population of U.S. radiologists. METHODS: A random selection of 110 of 292 radiologists who agreed to participate, if selected, interpreted screening mammograms from 148 randomly selected women. Original index mammograms (i.e., mediolateral oblique and craniocaudal views of each breast) were used; comparison original mammograms were provided when available. Radiologist-level and facility-level factors were surveyed. Two standard metrics of screening accuracy, both based on receiver operating characteristic curves, were analyzed. The influence of volume on accuracy after controlling for other factors was assessed with multiple regression analysis. RESULTS: Current reading volume was not statistically significantly associated with interpretive accuracy. More recently trained radiologists interpreted mammograms more accurately than those trained earlier (-0.76% [95% confidence interval (CI) = -1.75% to -0.02%] reduction in sensitivity per year since residency). Facility-level factors that were statistically significantly and independently associated with better accuracy were the number of diagnostic breast imaging examinations and image-guided breast interventional procedures performed (0.55% [95% CI = 0.11% to 2.40%] increase in accuracy per examination or procedure offered), being classified as a comprehensive breast diagnostic and/or screening center or freestanding mammography center (1.39% [95% CI = 0.15% to 3.82%] higher than a hospital radiology department or multispecialty medical clinic), and being a facility that practiced double reading (1.61% [95% CI = 1.99% to 11.65%]) higher than in a facility without such practice). CONCLUSIONS: Individual radiologists' current reading volume was not statistically significantly associated with accuracy in reading screening mammograms, but several other factors were. Expertise reflects a complex multifactorial process that needs further clarification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jnci/95.4.282

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

Metadata

Authors
Beam, C. A., Conant, E. F., & Sickles, E. A.
Venue
JNCI Journal of the National Cancer Institute
Published
2003-02-19
Volume
95
Issue
4
Pages
282-290
ISSN
  • 0027-8874 (ISSN-L)
  • 1460-2105
OpenAlex
W2096500778
Cited by
158
References
26
FWCI
11.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.