Piezo1 channels are mechanosensors in human fetoplacental endothelial cells
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
STUDY QUESTION: Does the shear stress sensing ion channel subunit Piezo1 have an important mechanotransduction role in human fetoplacental endothelium? SUMMARY ANSWER: Piezo1 is present and functionally active in human fetoplacental endothelial cells, and disruption of Piezo1 prevents the normal response to shear stress. WHAT IS KNOWN ALREADY: Shear stress is an important stimulus for maturation and function of placental vasculature but the molecular mechanisms by which the force is detected and transduced are unclear. Piezo1 channels are Ca2+-permeable non-selective cationic channels which are critical for shear stress sensing and maturation of murine embryonic vasculature. STUDY DESIGN, SAMPLES/MATERIALS, METHODS: We investigated the relevance of Piezo1 to placental vasculature by studying human fetoplacental endothelial cells (FpECs) from healthy pregnancies. Endothelial cells were isolated from placental cotyledons and cultured, for the study of tube formation and cell alignment to shear stress. In addition, human placental arterial endothelial cells were isolated and studied immediately by patch-clamp electrophysiology. MAIN RESULTS AND THE ROLE OF CHANCE: The synthetic Piezo1 channel agonist Yoda1 caused strong elevation of the intracellular Ca2+ concentration with a 50% effect occurring at about 5.4 μM. Knockdown of Piezo1 by RNA interference suppressed the Yoda1 response, consistent with it being mediated by Piezo1 channels. Alignment of cells to the direction of shear stress was also suppressed by Piezo1 knockdown without loss of cell viability. Patch-clamp recordings from freshly isolated endothelium showed shear stress-activated single channels which were characteristic of Piezo1. LIMITATIONS, REASONS FOR CAUTION: The in vitro nature of fetoplacental endothelial cell isolation and subsequent culture may affect FpEC characteristics and PIEZO1 expression. In addition to Piezo1, alternative shear stress sensing mechanisms have been suggested in other systems and might also contribute in the placenta. WIDER IMPLICATIONS OF THE FINDINGS: These data suggest that Piezo1 is an important molecular determinant of blood flow sensitivity in the placenta. Establishing and manipulating the molecular mechanisms regulating shear stress sensing could lead to novel therapeutic strategies to improve blood flow in the placenta. LARGE-SCALE DATA: Not applicable. STUDY FUNDING/COMPETING INTEREST(S): LCM was funded by a Clinical Research Training Fellowship from the Medical Research Council and by the Royal College of Obstetricians and Gynaecologists, and has received support from a Wellcome Trust Institutional Strategic Support Fund. JS was supported by the Wellcome Trust and a BHF Intermediate Research Fellowship. HJG, CW, AJH and PJW were supported by PhD Studentships from BHF, BBSRC and the Leeds Teaching Hospitals Charitable Foundation respectively. All authors declare no conflict of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316
Structure of the mechanically activated ion channel Piezo1
Saotome, K., Murthy, S. E., Kefauver, J. M., Whitwam, T., Patapoutian, A., & Ward, A. B. (2018) · Nature · doi:10.1038/nature25453 · Cited by 649 · cited 1×
“A central cap encloses the central gated ~25-pS calcium ion (Ca)-permeable nonselective cation channel (Ge et al., 2015; Guo and MacKinnon, 2017; Saotome et al., 2018; Zhao et al., 2018).”
BackgroundStructure and mechanogating mechanism of the Piezo1 channel
Zhao, Q., Zhou, H., Chi, S., Wang, Y., Wang, J., Geng, J., Wu, K., Liu, W., Zhang, T., Dong, M.-Q., et al. (2018) · Nature · doi:10.1038/nature25743 · Cited by 628
Endothelial cation channel PIEZO1 controls blood pressure by mediating flow-induced ATP release
Wang, S., Chennupati, R., Kaur, H., Iring, A., Wettschureck, N., & Offermanns, S. (2016) · Journal of Clinical Investigation · doi:10.1172/jci87343 · Cited by 616 · cited 1×
“Downstream signalling here also resulted in eNOS activation, along with AKT phosphorylation (Wang et al., 2016).”
BackgroundCox, C. D., Bae, C., Ziegler, L., Hartley, S., Nikolova-Krstevski, V., Rohde, P. R., Ng, C.-A., Sachs, F., Gottlieb, P. A., & Martinac, B. (2016) · Nature Communications · doi:10.1038/ncomms10366 · Cited by 528
Structure-based membrane dome mechanism for Piezo mechanosensitivity
Guo, Y. R., & MacKinnon, R. (2017) · eLife · doi:10.7554/elife.33660 · Cited by 446 · cited 2×
“By assembling as large trimers the blade components act as ‘force sensors’ within the vessel lumen, acting to regulate the ion-conducting pore (Ge et al., 2015; Guo and MacKinnon, 2017).”
BackgroundRode, B., Shi, J., Endesh, N., Drinkhill, M. J., Webster, P. J., Lotteau, S. J., Bailey, M. A., Yuldasheva, N. Y., Ludlow, M. J., Cubbon, R. M., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00429-3 · Cited by 305
Self-citationFetal and umbilical Doppler ultrasound in normal pregnancy
Alfirevic, Z., Stampalija, T., & Medley, N. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001450.pub4 · Cited by 198 · cited 3×
“This may result in absent or reversed blood flow at the end of diastole, indicating a foetus at high risk of FGR and stillbirth (Alfirevic et al., 2015; Jones et al., 2015).”
BackgroundMethod
Cited by
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Force Sensing by Piezo Channels in Cardiovascular Health and Disease
Beech, D. J., & Kalli, A. C. (2019) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.119.313348 · Cited by 242
Self-citationStructural and thermodynamic framework for PIEZO1 modulation by small molecules
Jiang, W., Wijerathne, T. D., Zhang, H., Lin, Y.-C., Jo, S., Im, W., Lacroix, J. J., & Luo, Y. L. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2310933120 · Cited by 44
Endothelial force sensing signals to parenchymal cells to regulate bile and plasma lipids
Lichtenstein, L., Cheng, C. W., Bajarwan, M., Evans, E. L., Gaunt, H. J., Bartoli, F., Chuntharpursat-Bon, E., Patel, S., Konstantinou, C., Futers, T. S., et al. (2024) · Science Advances · doi:10.1126/sciadv.adq3075 · Cited by 15
Self-citation
Metadata
- Authors
- Morley, L. C., Shi, J., Gaunt, H. J., Hyman, A. J., Webster, P. J., Williams, C., Forbes, K., Walker, J. J., Simpson, N. A. B., & Beech, D. J.
- Venue
- MHR: Basic science of reproductive medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-08-02
- Volume
- 24
- Issue
- 10
- Pages
- 510-520
- ISSN
- 1360-9947 (ISSN-L)
- 1460-2407
- OpenAlex
- W2886094490
- Cited by
- 65
- References
- 8
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Piezo1 channels are mechanosensors in human fetoplacental endothelial cells. https://app.cochat.ai/papers/10.1093/molehr/gay033
- The paper
- Morley, L. C., Shi, J., Gaunt, H. J., Hyman, A. J., Webster, P. J., Williams, C., Forbes, K., Walker, J. J., Simpson, N. A. B., & Beech, D. J. (2018). Piezo1 channels are mechanosensors in human fetoplacental endothelial cells. MHR: Basic science of reproductive medicine. https://doi.org/10.1093/molehr/gay033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.