Inter-laboratory variation in DNA damage using a standard comet assay protocol
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
There are substantial inter-laboratory variations in the levels of DNA damage measured by the comet assay. The aim of this study was to investigate whether adherence to a standard comet assay protocol would reduce inter-laboratory variation in reported values of DNA damage. Fourteen laboratories determined the baseline level of DNA strand breaks (SBs)/alkaline labile sites and formamidopyrimidine DNA glycosylase (FPG)-sensitive sites in coded samples of mononuclear blood cells (MNBCs) from healthy volunteers. There were technical problems in seven laboratories in adopting the standard protocol, which were not related to the level of experience. Therefore, the inter-laboratory variation in DNA damage was only analysed using the results from laboratories that had obtained complete data with the standard comet assay protocol. This analysis showed that the differences between reported levels of DNA SBs/alkaline labile sites in MNBCs were not reduced by applying the standard assay protocol as compared with the laboratory's own protocol. There was large inter-laboratory variation in FPG-sensitive sites by the laboratory-specific protocol and the variation was reduced when the samples were analysed by the standard protocol. The SBs and FPG-sensitive sites were measured in the same experiment, indicating that the large spread in the latter lesions was the main reason for the reduced inter-laboratory variation. However, it remains worrying that half of the participating laboratories obtained poor results using the standard procedure. This study indicates that future comet assay validation trials should take steps to evaluate the implementation of standard procedures in participating laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Comet Assay for DNA Damage and Repair: Principles, Applications, and Limitations
Collins, A. R. (2004) · Molecular Biotechnology · doi:10.1385/mb:26:3:249 · Cited by 2,892 · cited 1×
“We have reported primary comet assay end points as %T, or as visual score in arbitrary units on a 0–100 scale that corresponds fairly closely to that used for %T (18,19).”
MethodSelf-citationCadet, J., Douki, T., & Ravanat, J.-L. (2008) · Accounts of Chemical Research · doi:10.1021/ar700245e · Cited by 555
Cited by
The essential comet assay: a comprehensive guide to measuring DNA damage and repair
Azqueta, A., & Collins, A. R. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1070-0 · Cited by 497
Self-citationMeasuring DNA modifications with the comet assay: a compendium of protocols
Collins, A., Møller, P., Gajski, G., Vodenková, S., Abdulwahed, A., Anderson, D., Bankoglu, E. E., Bonassi, S., Boutet-Robinet, E., Brunborg, G., et al. (2023) · Nature Protocols · doi:10.1038/s41596-022-00754-y · Cited by 410
Self-citationWright, C., Milne, S., & Leeson, H. (2014) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2014.02.004 · Cited by 396
Møller, P., Azqueta, A., Boutet-Robinet, E., Koppen, G., Bonassi, S., Milić, M., Gajski, G., Costa, S., Teixeira, J. P., Costa Pereira, C., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0398-1 · Cited by 394
Self-citationIonizing-radiation induced DNA double-strand breaks: A direct and indirect lighting up
Vignard, J., Mirey, G., & Salles, B. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.06.013 · Cited by 315
Metadata
- Authors
- Forchhammer, L., Ersson, C., Loft, S., Möller, L., Godschalk, R. W. L., van Schooten, F. J., Jones, G. D. D., Higgins, J. A., Cooke, M., Mistry, V., Karbaschi, M., Collins, A. R., Azqueta, A., Phillips, D. H., Sozeri, O., Routledge, M. N., Nelson-Smith, K., Riso, P., Porrini, M., Matullo, G., Allione, A., Stępnik, M., Komorowska, M., Teixeira, J. P., Costa, S., Corcuera, L.-A., López de Cerain, A., Laffon, B., Valdiglesias, V., & Møller, P.
- Venue
- Mutagenesis
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-07-27
- Volume
- 27
- Issue
- 6
- Pages
- 665-672
- ISSN
- 0267-8357 (ISSN-L)
- 1464-3804
- OpenAlex
- W2102178501
- Cited by
- 91
- References
- 2
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.