CoChat

Inter-laboratory variation in DNA damage using a standard comet assay protocol

Open access
Forchhammer, Lykke, Ersson, Clara, Loft, Steffen, Möller, Lennart, Godschalk, Roger W. L., van Schooten, Frederik J., Jones, George D. D., Higgins, Jennifer A., Cooke, Marcus, Mistry, Vilas, Karbaschi, Mahsa, Collins, Andrew R., Azqueta, Amaya, Phillips, David H., Sozeri, Osman, Routledge, Michael N., Nelson-Smith, Kirsty, Riso, Patrizia, Porrini, Marisa, Matullo, Giuseppe, Allione, Alessandra, Stępnik, Maciej, Komorowska, Magdalena, Teixeira, João Paulo, Costa, Solange, Corcuera, Laura-Ana, López de Cerain, Adela, Laffon, Blanca, Valdiglesias, Vanessa, Møller, Peter · 2012 · Mutagenesis
Cited by 91

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

There are substantial inter-laboratory variations in the levels of DNA damage measured by the comet assay. The aim of this study was to investigate whether adherence to a standard comet assay protocol would reduce inter-laboratory variation in reported values of DNA damage. Fourteen laboratories determined the baseline level of DNA strand breaks (SBs)/alkaline labile sites and formamidopyrimidine DNA glycosylase (FPG)-sensitive sites in coded samples of mononuclear blood cells (MNBCs) from healthy volunteers. There were technical problems in seven laboratories in adopting the standard protocol, which were not related to the level of experience. Therefore, the inter-laboratory variation in DNA damage was only analysed using the results from laboratories that had obtained complete data with the standard comet assay protocol. This analysis showed that the differences between reported levels of DNA SBs/alkaline labile sites in MNBCs were not reduced by applying the standard assay protocol as compared with the laboratory's own protocol. There was large inter-laboratory variation in FPG-sensitive sites by the laboratory-specific protocol and the variation was reduced when the samples were analysed by the standard protocol. The SBs and FPG-sensitive sites were measured in the same experiment, indicating that the large spread in the latter lesions was the main reason for the reduced inter-laboratory variation. However, it remains worrying that half of the participating laboratories obtained poor results using the standard procedure. This study indicates that future comet assay validation trials should take steps to evaluate the implementation of standard procedures in participating laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/mutage/ges032

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Forchhammer, L., Ersson, C., Loft, S., Möller, L., Godschalk, R. W. L., van Schooten, F. J., Jones, G. D. D., Higgins, J. A., Cooke, M., Mistry, V., Karbaschi, M., Collins, A. R., Azqueta, A., Phillips, D. H., Sozeri, O., Routledge, M. N., Nelson-Smith, K., Riso, P., Porrini, M., Matullo, G., Allione, A., Stępnik, M., Komorowska, M., Teixeira, J. P., Costa, S., Corcuera, L.-A., López de Cerain, A., Laffon, B., Valdiglesias, V., & Møller, P.
Venue
Mutagenesis
Published
2012-07-27
Volume
27
Issue
6
Pages
665-672
ISSN
  • 0267-8357 (ISSN-L)
  • 1464-3804
OpenAlex
W2102178501
Cited by
91
References
2
FWCI
2.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.