The DOI matches its Crossref record.
Nearly all single base substitutions in DNA fragments joined to a GC-clamp can be detected by denaturing gradient gel electrophoresis
Open accessAbstract
Duplex DNA fragments differing by single base substitutions can be separated by electrophoresis in denaturing gradient polyacrylamide gels, but only substitutions in a restricted part of the molecule lead to a separation (1). In an effort to circumvent this problem, we demonstrated that the melting properties and electrophoretic behavior of a 135 base pair DNA fragment containing a beta-globin promoter are changed by attaching a GC-rich sequence, called a 'GC-clamp' (2). We predicted that these changes should make it possible to resolve most, if not all, single base substitutions within fragments attached to the clamp. To test this possibility we examined the effect of several different single base substitutions on the electrophoretic behavior of the beta-globin promoter fragment in denaturing gradient gels. We find that the GC-clamp allows the separation of fragments containing substitutions throughout the promoter fragment. Many of these substitutions do not lead to a separation when the fragment is not attached to the clamp. Theoretical calculations and analysis of a large number of different mutations indicate that approximately 95% of all possible single base substitutions should be separable when attached to a GC-clamp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PCR-DGGE fingerprinting: novel strategies for detection of microbes in food
Ercolini, D. (2004) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2003.11.006 · Cited by 624
Guillaume J.J.M., V. E., Schoone, G. J., Kroon, N. C. M., & Ebeling, S. B. (1992) · Molecular and Biochemical Parasitology · doi:10.1016/0166-6851(92)90208-2 · Cited by 377
The rapid detection of unknown mutations in nucleic acids
Grompe, M. (1993) · Nature Genetics · doi:10.1038/ng1093-111 · Cited by 310
Further Evidence for an Association of ABCR Alleles with Age-Related Macular Degeneration
Allikmets, R. (2000) · The American Journal of Human Genetics · doi:10.1086/303018 · Cited by 303
Human immunodeficiency virus type 1 evolution in vivo tracked by DNA heteroduplex mobility assays
Delwart, E. L., Sheppard, H. W., Walker, B. D., Goudsmit, J., & Mullins, J. I. (1994) · Journal of Virology · doi:10.1128/jvi.68.10.6672-6683.1994 · Cited by 296
Metadata
- Authors
- Myers, R. M., Fischer, S. G., Lerman, L. S., & Maniatis, T.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1985
- Volume
- 13
- Issue
- 9
- Pages
- 3131-3145
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2053631253
- Cited by
- 596
- References
- 0
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nearly all single base substitutions in DNA fragments joined to a GC-clamp can be detected by denaturing gradient gel electrophoresis. https://app.cochat.ai/papers/10.1093/nar/13.9.3131
- The paper
- Myers, R. M., Fischer, S. G., Lerman, L. S., & Maniatis, T. (1985). Nearly all single base substitutions in DNA fragments joined to a GC-clamp can be detected by denaturing gradient gel electrophoresis. Nucleic Acids Research. https://doi.org/10.1093/nar/13.9.3131
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.