The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A rapid chemiluminescent method for quanititation of human DNA
Open accessAbstract
A sensitive and simple method for the quantitation of human DNA is described. This method is based on probe hybridization to a human alpha satellite locus, D17Z1. The biotinylated probe is hybridized to sample DNA immobilized on nylon membrane. The subsequent binding of streptavidin-horseradish peroxidase to the bound probe allows for chemiluminescent detection using a luminol-based reagent and X-ray film. Less than 150 pg of human DNA can easily be detected with a 15 minute exposure. The entire procedure can be performed in 1.5 hours. Microgram quantities of nonhuman DNA have been tested and the results indicate very high specificity for human DNA. The data on film can be scanned into a computer and a commercially available program can be used to create a standard curve where DNA quantity is plotted against the mean density of each slot blot signal. The methods described can also be applied to the very sensitive determination of quantity and quality (size) of DNA on Southern blots. The high sensitivity of this quantitation method requires the consumption of only a fraction of sample for analysis. Determination of DNA quantity is necessary for RFLP and many PCR-based tests where optimal results are obtained only with a relatively narrow range of DNA quantities. The specificity of this quantitation method for human DNA will be useful for the analysis of samples that may also contain bacterial or other non-human DNA, for example forensic evidence samples, ancient DNA samples, or clinical samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Cited by
An investigation of the rigor of interpretation rules for STRs derived from less than 100 pg of DNA
Gill, P., Whitaker, J., Flaxman, C., Brown, N., & Buckleton, J. (2000) · Forensic Science International · doi:10.1016/s0379-0738(00)00158-4 · Cited by 610
Demeke, T., & Jenkins, G. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3150-9 · Cited by 403
Fundamentals of Forensic DNA Typing
(2010) · Elsevier eBooks · doi:10.1016/c2009-0-01945-x · Cited by 383
Kimpton, C., Fisher, D., Watson, S., Adams, M., Urquhart, A., Lygo, J., & Gill, P. (1994) · International Journal of Legal Medicine · doi:10.1007/bf01224776 · Cited by 183
Practical applications of genotypic surveys for forensic STR testing
Holt, C. L., Stauffer, C., Wallin, J. M., Lazaruk, K. D., Nguyen, T., Budowle, B., & Walsh, P. S. (2000) · Forensic Science International · doi:10.1016/s0379-0738(00)00169-9 · Cited by 41
Self-citation
Metadata
- Authors
- Walsh, P. S., Varlaro, J., & Reynolds, R.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1992
- Volume
- 20
- Issue
- 19
- Pages
- 5061-5065
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2148598886
- Cited by
- 187
- References
- 1
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A rapid chemiluminescent method for quanititation of human DNA. https://app.cochat.ai/papers/10.1093/nar/20.19.5061
- The paper
- Walsh, P. S., Varlaro, J., & Reynolds, R. (1992). A rapid chemiluminescent method for quanititation of human DNA. Nucleic Acids Research. https://doi.org/10.1093/nar/20.19.5061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.