Nanoliter high throughput quantitative PCR
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Understanding biological complexity arising from patterns of gene expression requires accurate and precise measurement of RNA levels across large numbers of genes simultaneously. Real time PCR (RT-PCR) in a microtiter plate is the preferred method for quantitative transcriptional analysis but scaling RT-PCR to higher throughputs in this fluidic format is intrinsically limited by cost and logistic considerations. Hybridization microarrays measure the transcription of many thousands of genes simultaneously yet are limited by low sensitivity, dynamic range, accuracy and sample throughput. The hybrid approach described here combines the superior accuracy, precision and dynamic range of RT-PCR with the parallelism of a microarray in an array of 3072 real time, 33 nl polymerase chain reactions (RT-PCRs) the size of a microscope slide. RT-PCR is demonstrated with an accuracy and precision equivalent to the same assay in a 384-well microplate but in a 64-fold smaller reaction volume, a 24-fold higher analytical throughput and a workflow compatible with standard microplate protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609
Cited by
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Twenty-Five Years of Quantitative PCR for Gene Expression Analysis
VanGuilder, H. D., Vrana, K. E., & Freeman, W. M. (2008) · BioTechniques · doi:10.2144/000112776 · Cited by 1,246
Expósito-Rodríguez, M., Borges, A. A., Borges-Pérez, A., & Pérez, J. A. (2008) · BMC Plant Biology · doi:10.1186/1471-2229-8-131 · Cited by 787
PrimerBank: a PCR primer database for quantitative gene expression analysis, 2012 update
Wang, X., Spandidos, A., Wang, H., & Seed, B. (2012) · Nucleic Acids Research · doi:10.1093/nar/gkr1013 · Cited by 720
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Schrödinger’s microbes: Tools for distinguishing the living from the dead in microbial ecosystems
Emerson, J. B., Adams, R. I., Román, C. M. B., Brooks, B., Coil, D. A., Dahlhausen, K., Ganz, H. H., Hartmann, E. M., Hsu, T., Justice, N. B., et al. (2017) · Microbiome · doi:10.1186/s40168-017-0285-3 · Cited by 515
Zhang, C., & Xing, D. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm389 · Cited by 417
Lun, F. M. F., Tsui, N. B. Y., Chan, K. C. A., Leung, T. Y., Lau, T. K., Charoenkwan, P., Chow, K. C. K., Lo, W. Y. W., Wanapirak, C., Sanguansermsri, T., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810373105 · Cited by 355
Cell Fate Decision as High-Dimensional Critical State Transition
Mojtahedi, M., Skupin, A., Zhou, J., Castaño, I. G., Leong-Quong, R. Y. Y., Chang, H., Trachana, K., Giuliani, A., & Huang, S. (2016) · PLOS Biology · doi:10.1371/journal.pbio.2000640 · Cited by 350
High-Throughput Quantitative Polymerase Chain Reaction in Picoliter Droplets
Kiss, M. M., Ortoleva-Donnelly, L., Beer, N. R., Warner, J., Bailey, C. G., Colston, B. W., Rothberg, J. M., Link, D. R., & Leamon, J. H. (2008) · Analytical Chemistry · doi:10.1021/ac801276c · Cited by 326
Postel, M., Roosen, A., Laurent-Puig, P., Taly, V., & Wang-Renault, S.-F. (2018) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2018.1400384 · Cited by 254
Weaver, S., Dube, S., Mir, A., Qin, J., Sun, G., Ramakrishnan, R., Jones, R. C., & Livak, K. J. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.003 · Cited by 220
Microfluidics for Biomedical Analysis
Yang, Y., Chen, Y., Tang, H., Zong, N., & Jiang, X. (2020) · Small Methods · doi:10.1002/smtd.201900451 · Cited by 217
Integrated Classification of Prostate Cancer Reveals a Novel Luminal Subtype with Poor Outcome
You, S., Knudsen, B. S., Erho, N., Alshalalfa, M., Takhar, M., Al-deen Ashab, H., Davicioni, E., Karnes, R. J., Klein, E. A., Den, R. B., et al. (2016) · Cancer Research · doi:10.1158/0008-5472.can-16-0902 · Cited by 202
“that the classifier can be applied to subtype individual PCs using clinically relevant technology platforms (43,44), including by noninvasive methods.”
BackgroundStedtfeld, R. D., Guo, X., Stedtfeld, T. M., Sheng, H., Williams, M. R., Hauschild, K., Gunturu, S., Tift, L., Wang, F., Howe, A., et al. (2018) · FEMS Microbiology Ecology · doi:10.1093/femsec/fiy130 · Cited by 184
Droplets for Ultrasmall-Volume Analysis
Chiu, D. T., Lorenz, R. M., & Jeffries, G. D. M. (2009) · Analytical Chemistry · doi:10.1021/ac900306q · Cited by 182
Digital PCR analysis of circulating nucleic acids
Hudecova, I. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.03.015 · Cited by 178
“The first generation of dPCR platforms were based on chips containing microfluidic channels such as those made by Fluidigm [15] and plates with hydrophilic and hydrophobic surfaces such as those by Life Technologies [16].”
MethodNo Control Genes Required: Bayesian Analysis of qRT-PCR Data
Matz, M. V., Wright, R. M., & Scott, J. G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071448 · Cited by 177
“3 d), supporting the basic assumption that the higher variance at higher Cq is due to Poisson fluctuation in numbers of sampled molecules [28].”
BackgroundResultInfluentialExploiting the ecogenomics toolbox for environmental diagnostics of organohalide-respiring bacteria
Maphosa, F., de Vos, W. M., & Smidt, H. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.03.005 · Cited by 169
Digital PCR to Determine the number of Transcripts from Single Neurons after Patch-Clamp Recording
Faragó, N., Kocsis, Á. K., Lovas, S., Molnár, G., Boldog, E., Rózsa, M., Szemenyei, V., Vámos, E., Nagy, L. I., Tamás, G., et al. (2013) · BioTechniques · doi:10.2144/000114029 · Cited by 26
Summerer, D., Hevroni, D., Jain, A., Oldenburger, O., Parker, J., Caruso, A., Stähler, C. F., Stähler, P. F., & Beier, M. (2010) · New Biotechnology · doi:10.1016/j.nbt.2010.03.005 · Cited by 12
Metadata
- Authors
- Morrison, T., Hurley, J., Garcia, J., Yoder, K., Katz, A., Roberts, D., Cho, J., Kanigan, T., Ilyin, S. E., Horowitz, D., Dixon, J. M., & Brenan, C. J. H.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-09-25
- Volume
- 34
- Issue
- 18
- Pages
- e123-e123
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2101814635
- Cited by
- 222
- References
- 1
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.