CoChat

Homogeneous antibody-based proximity extension assays provide sensitive and specific detection of low-abundant proteins in human blood

Open access
Lundberg, Martin, Eriksson, Anna, Tran, Bonnie, Assarsson, Erika, Fredriksson, Simon · 2011 · Nucleic Acids Research

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Convenient and well-performing protein detection methods for a wide range of targets are in great demand for biomedical research and future diagnostics. Assays without the need for washing steps while still unaffected when analyzing complex biological samples are difficult to develop. Herein, we report a well-characterized nucleic acid proximity-based assay using antibodies, called Proximity Extension Assay (PEA), showing good performance in plasma samples. Target-specific antibody pairs are linked to DNA strands that upon simultaneous binding to the target analyte create a real-time PCR amplicon in a proximity-dependent manner enabled by the action of a DNA polymerase. 3'Exonuclease-capable polymerases were found to be clearly superior in sensitivity over non-3'exonuclease ones. A PEA was set up for IL-8 and GDNF in a user-friendly, homogenous assay displaying femtomolar detection sensitivity, good recovery in human plasma, high specificity and up to 5-log dynamic range in 1 μL samples. Furthermore, we have illustrated the use of a macro-molecular crowding matrix in combination with this homogeneous assay to drive target binding for low-affinity antibodies, thereby improving the sensitivity and increasing affinity reagent availability by lowering assay development dependency on high-affinity antibodies. Assay performance was also confirmed for a multiplex version of PEA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/nar/gkr424

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Schematic description of the PEA. Upon sample incubation, the proximity probe pair binds its specific antigen. As a result, the probe oligos come in close proximity and hybridize to each other. The addition of a DNA polymerase leads to an extension of the hybridizing oligo. Finally, this results in a DNA template that can be detected and quantified by qPCR.
Figure 1. Schematic description of the PEA. Upon sample incubation, the proximity probe pair binds its specific antigen. As a result, the probe oligos come in close proximity and hybridize to each other. The addition of a DNA polymerase leads to an extension of the hybridizing oligo. Finally, this results in a DNA template that can be detected and quantified by qPCR.CC BY-NC · PubMed Central
Figure 2. Exonuclease activity and hybridization length affects assay sensitivity. (A) VEGF assays were designed with different lengths of the hybridization site and compared with respect to sensitivity. A 9-nt hybridization site was found to give the best signal-to-noise levels and was selected for further studies. (B) Different DNA polymerases were tested with regards to their ability to generate good sensitivity in an IL-8-specific assay. T4 DNA polymerase I, DNA polymerase I and Klenow fragment exo+ all possess a 3′→5′ exonuclease activity and performed well in the IL-8 detection. Klenow fragment exo−, on the other hand, generated a background signal that was almost at the level of the antigen-induced signal. When exogenous Exonuclease I was added to the reaction, the signal-to-noise level was restored.
Figure 2. Exonuclease activity and hybridization length affects assay sensitivity. (A) VEGF assays were designed with different lengths of the hybridization site and compared with respect to sensitivity. A 9-nt hybridization site was found to give the best signal-to-noise levels and was selected for further studies. (B) Different DNA polymerases were tested with regards to their ability to generate good sensitivity in an IL-8-specific assay. T4 DNA polymerase I, DNA polymerase I and Klenow fragment exo+ all possess a 3′→5′ exonuclease activity and performed well in the IL-8 detection. Klenow fragment exo−, on the other hand, generated a background signal that was almost at the level of the antigen-induced signal. When exogenous Exonuclease I was added to the reaction, the signal-to-noise level was restored.CC BY-NC · PubMed Central
Figure 3. Detection of low-abundant analytes in human blood plasma. Assays were generated for human IL-8 (A) and GDNF (B). Buffer or a blood plasma sample were spiked with either IL-8 or GDNF at concentrations between 0.1 pM and 10 nM, and measured with PEA. Signal is plotted as Ct values. Both IL-8 and GDNF, two low-abundant analytes, were detectable in plasma. Both assays showed a good sensitivity with the lower detection limit at, or below, 0.1 pM.
Figure 3. Detection of low-abundant analytes in human blood plasma. Assays were generated for human IL-8 (A) and GDNF (B). Buffer or a blood plasma sample were spiked with either IL-8 or GDNF at concentrations between 0.1 pM and 10 nM, and measured with PEA. Signal is plotted as Ct values. Both IL-8 and GDNF, two low-abundant analytes, were detectable in plasma. Both assays showed a good sensitivity with the lower detection limit at, or below, 0.1 pM.CC BY-NC · PubMed Central
Figure 4. Increased target binding and enhancement of the PEA performance by upon macro-molecular crowding. (A) Different sephadex matrices were used during the probe/target incubation of an ICAM assay to test if exclusion of water from the reaction could improve assay performance. Signal is plotted as Ct values. (B) Complete standard curve for ICAM (10 nM–0.1 pM) is shown for assays performed with (gray) or without (white) sephadex G100. (C) Multiplex PEA was performed for 15 assays, and the signal-to-noise was determined at 200 pM antigen concentration. Signal-to-noise (dCt) is plotted as a function of the increase in signal-to-noise derived from sephadex G100 inclusion (ddCt). Five assays were improved (white), eight remained unchanged (gray) and three were impaired (black). (D) Buffer was spiked with 100 pM VEGF, and incubated with (gray) or without (white) sephadex G100. PEA was performed after different time points after incubation. Signal-to-noise (dCt) is plotted as a function of incubation time.
Figure 4. Increased target binding and enhancement of the PEA performance by upon macro-molecular crowding. (A) Different sephadex matrices were used during the probe/target incubation of an ICAM assay to test if exclusion of water from the reaction could improve assay performance. Signal is plotted as Ct values. (B) Complete standard curve for ICAM (10 nM–0.1 pM) is shown for assays performed with (gray) or without (white) sephadex G100. (C) Multiplex PEA was performed for 15 assays, and the signal-to-noise was determined at 200 pM antigen concentration. Signal-to-noise (dCt) is plotted as a function of the increase in signal-to-noise derived from sephadex G100 inclusion (ddCt). Five assays were improved (white), eight remained unchanged (gray) and three were impaired (black). (D) Buffer was spiked with 100 pM VEGF, and incubated with (gray) or without (white) sephadex G100. PEA was performed after different time points after incubation. Signal-to-noise (dCt) is plotted as a function of incubation time.CC BY-NC · PubMed Central
Figure 5. Multiplex PEA protein detection. Buffer was spiked with 23 analytes from panel 1 or 2 (see ‘Materials and Methods’ section and Supplementary Table SI) at concentrations between 0.1 and 100 pM, and measured either with singleplex (white) or multiplex PEA (gray). Results for (A) IL-8, (B) GDNF, (C) CAIX and (D) IL-17 are shown. Signal is plotted as Ct values.
Figure 5. Multiplex PEA protein detection. Buffer was spiked with 23 analytes from panel 1 or 2 (see ‘Materials and Methods’ section and Supplementary Table SI) at concentrations between 0.1 and 100 pM, and measured either with singleplex (white) or multiplex PEA (gray). Results for (A) IL-8, (B) GDNF, (C) CAIX and (D) IL-17 are shown. Signal is plotted as Ct values.CC BY-NC · PubMed Central
Figure 6. Linearity of dilution in plasma. Linearity of dilution was assessed by measuring six low-abundant (A), six mid-abundant (B) and six high-abundant (C) markers at different concentrations of plasma in multiplex. Signal-to-noise values (dCt) are plotted at three different concentrations of plasma for each set of analytes. Linearity was observed for assays with either high or low signals in plasma, and also for undiluted and highly diluted plasma samples.
Figure 6. Linearity of dilution in plasma. Linearity of dilution was assessed by measuring six low-abundant (A), six mid-abundant (B) and six high-abundant (C) markers at different concentrations of plasma in multiplex. Signal-to-noise values (dCt) are plotted at three different concentrations of plasma for each set of analytes. Linearity was observed for assays with either high or low signals in plasma, and also for undiluted and highly diluted plasma samples.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 744

Metadata

Authors
Lundberg, M., Eriksson, A., Tran, B., Assarsson, E., & Fredriksson, S.
Affiliations
Olink Bioscience (Sweden) (SE)
Corresponding author
Fredriksson, Simon
Venue
Nucleic Acids Research
Published
2011-06-06
Volume
39
Issue
15
Pages
e102-e102
ISSN
  • 0305-1048 (ISSN-L)
  • 1362-4962
OpenAlex
W2061538346
Cited by
744
References
14
Citations by year
2026: 84 · 2025: 95 · 2024: 95 · 2023: 83 · 2022: 70 · 2021: 73 · 2020: 59 · 2019: 45 · 2018: 40 · 2017: 31 · 2016: 21 · 2015: 15 · 2014: 14 · 2013: 10 · 2012: 6
FWCI
4.26
Type
journal article
Language
en
Open access
Locations
  • Nucleic Acids Research (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
European Commission (222950)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
Keywords
proximity extension assay, homogeneous immunoassay, human plasma, interleukin-8, glial cell line-derived neurotrophic factor, low-affinity antibodies, multiplex immunoassay, femtomolar sensitivity
MeSH terms
Antibodies, Blood Proteins, Exonucleases, Humans, Immunoassay, Water, Oligonucleotide Probes, Polymerase Chain Reaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.