CoChat

Systematic bias in high-throughput sequencing data and its correction by BEADS

Open access

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Genomic sequences obtained through high-throughput sequencing are not uniformly distributed across the genome. For example, sequencing data of total genomic DNA show significant, yet unexpected enrichments on promoters and exons. This systematic bias is a particular problem for techniques such as chromatin immunoprecipitation, where the signal for a target factor is plotted across genomic features. We have focused on data obtained from Illumina's Genome Analyser platform, where at least three factors contribute to sequence bias: GC content, mappability of sequencing reads, and regional biases that might be generated by local structure. We show that relying on input control as a normalizer is not generally appropriate due to sample to sample variation in bias. To correct sequence bias, we present BEADS (bias elimination algorithm for deep sequencing), a simple three-step normalization scheme that successfully unmasks real binding patterns in ChIP-seq data. We suggest that this procedure be done routinely prior to data interpretation and downstream analyses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/nar/gkr425

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. DNA fragments in high-throughput sequencing data are not uniformly distributed over the genome. (a) The patterns of raw sequencing signals of independent C. elegans input sequence extracts and genomic DNA samples (black) are similar to underlying GC content (red) and mappability (blue). Positions 11 075 000–11 098 000 of chromosome I of the C. elegans genome are shown. (b) GC frequency distributions of the C. elegans genome (solid line) and a set of input sequence reads (dashed line). (c) GC frequency ratio between input sequence data and the C. elegans genome.
Figure 1. DNA fragments in high-throughput sequencing data are not uniformly distributed over the genome. (a) The patterns of raw sequencing signals of independent C. elegans input sequence extracts and genomic DNA samples (black) are similar to underlying GC content (red) and mappability (blue). Positions 11 075 000–11 098 000 of chromosome I of the C. elegans genome are shown. (b) GC frequency distributions of the C. elegans genome (solid line) and a set of input sequence reads (dashed line). (c) GC frequency ratio between input sequence data and the C. elegans genome.CC BY-NC · PubMed Central
Figure 2. Bias in GC content (a, d, g, j), mappability (b, e, h, k) and raw input sequence signals (c, f, i, l) across internal exons and around transcript start sites in C. elegans and human. The error bars represent the 95% confidence intervals of the estimated mean GC, mappability or sequence signal values.
Figure 2. Bias in GC content (a, d, g, j), mappability (b, e, h, k) and raw input sequence signals (c, f, i, l) across internal exons and around transcript start sites in C. elegans and human. The error bars represent the 95% confidence intervals of the estimated mean GC, mappability or sequence signal values.CC BY-NC · PubMed Central
Figure 3. BEADS normalization of high-throughput sequence reads of C. elegans input sequence (a, b), H3K4me3 ChIP (c, d), H3K36me3 ChIP (e, f) and human input sequence (g, h) libraries. Shown are the results following each step of correction: Raw (uncorrected), GC corrected, GC + mappability corrected, and GC + mappability + local corrected signals. Plots show signals across internal exons and around transcript start sites of all genes; except in d and f, only transcript start sites of highly expressed genes were used (see ‘Materials and Methods’ section). The normalized signals are plotted as relative normalized read counts (left-hand y-axis). The fully normalized signal is also plotted as fold-change relative to the genomic average (right-hand y-axis). Solid lines show average signal and shaded regions show 95% confidence intervals. Genomic read-count averages for the C. elegans input-control, H3K4me3, H3K36me3 and human input-control libraries are 33.0, 29.8, 14.6 and 0.4, respectively.
Figure 3. BEADS normalization of high-throughput sequence reads of C. elegans input sequence (a, b), H3K4me3 ChIP (c, d), H3K36me3 ChIP (e, f) and human input sequence (g, h) libraries. Shown are the results following each step of correction: Raw (uncorrected), GC corrected, GC + mappability corrected, and GC + mappability + local corrected signals. Plots show signals across internal exons and around transcript start sites of all genes; except in d and f, only transcript start sites of highly expressed genes were used (see ‘Materials and Methods’ section). The normalized signals are plotted as relative normalized read counts (left-hand y-axis). The fully normalized signal is also plotted as fold-change relative to the genomic average (right-hand y-axis). Solid lines show average signal and shaded regions show 95% confidence intervals. Genomic read-count averages for the C. elegans input-control, H3K4me3, H3K36me3 and human input-control libraries are 33.0, 29.8, 14.6 and 0.4, respectively.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 172

Metadata

Authors
Cheung, M.-S., Down, T. A., Latorre, I., & Ahringer, J.
Affiliations
University of Cambridge (GB)
Corresponding author
Ahringer, Julie
Venue
Nucleic Acids Research
Published
2011-06-06
Volume
39
Issue
15
Pages
e103-e103
ISSN
  • 0305-1048 (ISSN-L)
  • 1362-4962
OpenAlex
W1988650678
Cited by
160
References
29
Citations by year
2026: 1 · 2025: 4 · 2024: 13 · 2023: 1 · 2022: 6 · 2021: 10 · 2020: 10 · 2019: 10 · 2018: 12 · 2017: 11 · 2016: 8 · 2015: 13 · 2014: 25 · 2013: 16 · 2012: 17
FWCI
7.93
Type
journal article
Language
en
Open access
Locations
  • Nucleic Acids Research (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Apollo (University of Cambridge) (submittedVersion, cc-by-nc)
  • Apollo
Funders
  • Wellcome Trust (054523)
  • Cancer Research UK
  • National Human Genome Research Institute (U01HG004270)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Chromatin Dynamics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
Keywords
sequencing bias, bias correction, beads, ChIP-seq, normalization, GC content, promoter enrichment, input control, sample-to-sample variation, binding patterns
MeSH terms
Algorithms, Animals, Base Composition, Caenorhabditis elegans, Sequence Analysis, DNA, DNA, Helminth, Chromatin Immunoprecipitation, High-Throughput Nucleotide Sequencing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.