Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 182

The DOI matches its Crossref record.

Haemodialysis vascular access problems in Canada: results from the Dialysis Outcomes and Practice Patterns Study (DOPPS II)

Mendelssohn, David C., Ethier, Jean, Elder, Stacey J., Saran, Rajiv, Port, Friedrich K., Pisoni, Ronald L. · 2006 · Nephrology Dialysis Transplantation

Abstract

BACKGROUND: The optimal vascular access for chronic maintenance haemodialysis (HD) is the native arteriovenous fistula (AVF). Vascular access practice patterns are reported for a Canadian cohort of patients from the Dialysis Outcomes and Practice Patterns Study (DOPPS II). METHODS: DOPPS II is a prospective, observational study in 12 countries, including Canada. A representative random sample of 20 Canadian HD facilities and patients within those units were studied during 2002-2004. Canadian results were compared with those found in Europe and the USA. RESULTS: AVF use in Canadian prevalent (53%) and incident (26%) patients was lower than Canadian guidelines recommend (60%), and lower than in Europe [prevalent (74%), incident (50%)]. Despite 85% of Canadian HD patients having seen a nephrologist for > 1 month prior to starting dialysis, central venous catheter use in Canada (33% in prevalent patients, 70% in incident patients) was much higher than in Europe (prevalent 18%, incident 46%) and slightly higher than in the USA (prevalent 25%, incident 66%). This pattern is contrary to the preferences of Canadian medical directors and vascular access surgeons. The typical time from referral until permanent vascular access creation is substantially longer in Canada (61.7 days) than in Europe (29.4 days) or the USA (16 days). This longer delay time and higher catheter use in Canada may be a consequence of the significantly lower number of access surgeons per 100 HD patients in Canada (2.9) compared with the USA (8.1) and Europe (4.6). Furthermore, the median hours per week devoted to vascular access-related surgery per 100 patients is substantially lower in Canada (0.027 h) compared with the USA (0.082 h) and Europe (0.059 h). CONCLUSION: These findings suggest that Canadian chronic HD patients often rely on central venous catheters for vascular access, despite their known association with numerous detrimental outcomes in HD. Nephrologists, vascular access surgeons, interventional radiologists, other physicians and health care funding bodies must be more broadly educated about the priority of AVF creation as the preferred vascular access for chronic HD patients. They must work together to secure both the human and financial resources and other health care system enhancements to increase AVF creation rates in a timely manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfi281

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Mendelssohn, D. C., Ethier, J., Elder, S. J., Saran, R., Port, F. K., & Pisoni, R. L.
Venue
Nephrology Dialysis Transplantation
Published
2005-11-25
Volume
21
Issue
3
Pages
721-728
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2096308053
Cited by
182
References
0
FWCI
22.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Haemodialysis vascular access problems in Canada: results from the Dialysis Outcomes and Practice Patterns Study (DOPPS II). https://app.cochat.ai/papers/10.1093/ndt/gfi281
The paper
Mendelssohn, D. C., Ethier, J., Elder, S. J., Saran, R., Port, F. K., & Pisoni, R. L. (2006). Haemodialysis vascular access problems in Canada: results from the Dialysis Outcomes and Practice Patterns Study (DOPPS II). Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfi281

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.