The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis
Abstract
BACKGROUND: Despite recent clinical and technological advancements, the vascular access (VA) for haemodialysis still has significant early failure rates after arteriovenous fistula (AVF) creation. VA failure is mainly related to the haemodynamic conditions that trigger the phenomena of vascular wall disease such as intimal hyperplasia (IH) or atherosclerosis. METHODS: We performed transient computational fluid dynamics simulations within idealized three-dimensional models of 'end-to-side' and 'end-to-end' radio-cephalic anastomosis, using non-Newtonian blood and previously measured flows and division ratio in subjects requiring primary access procedure as boundary conditions. RESULTS: The numerical simulations allowed full characterization of blood flow inside the AVF and of patterns of haemodynamic shear stress, known to be the major determinant of vascular remodelling and disease. Wall shear stress was low and oscillating in zones where flow stagnation occurs on the artery floor and on the inner wall of the juxta-anastomotic vein. CONCLUSIONS: Zones of low and oscillatory shear stress were located in the same sites where luminal reduction was documented in previous experimental studies on sites stenosis distribution in AVF. We conclude that even when exposed to high flow rates, there are spot regions along the AVF exposed to athero-prone shear stress that favour vessel stenosis by triggering IH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Shear Stress–Initiated Signaling and Its Regulation of Endothelial Function
Zhou, J., Li, Y.-S., & Chien, S. (2014) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.114.303422 · Cited by 561
The molecular mechanisms of hemodialysis vascular access failure
Brahmbhatt, A., Remuzzi, A., Franzoni, M., & Misra, S. (2016) · Kidney International · doi:10.1016/j.kint.2015.12.019 · Cited by 259
Self-citation
Metadata
- Authors
- Ene-Iordache, B., & Remuzzi, A.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-07-18
- Volume
- 27
- Issue
- 1
- Pages
- 358-368
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2101746663
- Cited by
- 188
- References
- 1
- FWCI
- 11.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis. https://app.cochat.ai/papers/10.1093/ndt/gfr342
- The paper
- Ene-Iordache, B., & Remuzzi, A. (2012). Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfr342
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.