Glomerular filtration rate estimation using cystatin C alone or combined with creatinine as a confirmatory test
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Glomerular filtration rate (GFR) estimating equations using the combination of creatinine and cystatin C (eGFRcr-cys) are more accurate than equations using either alone (eGFRcr or eGFRcys). New guidelines suggest measuring cystatin C as a confirmatory test when eGFRcr may be inaccurate, but do not specify demographic or clinical conditions in which eGFRcys or eGFRcr-cys are more accurate than eGFRcr nor which estimate to use in such circumstances. METHODS: We compared the performance of the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations in 1119 subjects in the CKD-EPI cystatin C external validation dataset. Subgroups were defined by eGFRcr, age, sex, diabetes status and body mass index (BMI). The reference test was GFR measured using urinary or plasma clearance of exogenous filtration markers. Cystatin C and creatinine assays were traceable to primary reference materials. Accuracy was defined as the absolute difference in eGFR compared with mGFR. RESULTS: The mean mGFR was 70 ± 41 (SD) mL/min/1.73 m(2). eGFRcys was more accurate than eGFRcr at lower BMI and less accurate at higher BMI, especially at higher levels of eGFRcr. There were small differences in accuracy in people according to the diabetes status. eGFRcr-cys was as accurate or more accurate than eGFRcr or eGFRcys in these and all other subgroups. CONCLUSIONS: eGFRcr-cys, but not eGFRcys, is more accurate than eGFRcr in most subgroups we studied, suggesting preferential use of eGFRcr-cys when serum cystatin C is measured as a confirmatory test to obtain more accurate eGFR. Further studies are necessary to evaluate diagnostic strategies for using eGFRcys and eGFRcr-cys.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Self-citationEstimating glomerular filtration rate from serum creatinine and cystatin C
Inker, L. A., Schmid, C. H., Tighiouart, H., Eckfeldt, J. H., Feldman, H. I., Greene, T., Kusek, J. W., Manzi, J., Van Lente, F., Zhang, Y. L., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114248 · Cited by 4,102 · cited 5×
“Details of the studies and their measurement procedures have been previously published [1].”
BackgroundMethodResultInfluentialSelf-citationFactors other than glomerular filtration rate affect serum cystatin C levels
Stevens, L. A., Schmid, C. H., Greene, T., Li, L., Beck, G. J., Joffe, M. M., Froissart, M., Kusek, J. W., Zhang, Y. (., Coresh, J., et al. (2009) · Kidney International · doi:10.1038/ki.2008.638 · Cited by 809
Self-citation
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Self-citationKDIGO Clinical Practice Guideline on the Evaluation and Care of Living Kidney Donors
Lentine, K. L., Kasiske, B. L., Levey, A. S., Adams, P. L., Alberú, J., Bakr, M. A., Gallon, L., Garvey, C. A., Guleria, S., Li, P. K.-T., et al. (2017) · Transplantation · doi:10.1097/tp.0000000000001769 · Cited by 582
Self-citationEstimated GFR: time for a critical appraisal
Porrini, E., Ruggenenti, P., Luis-Lima, S., Carrara, F., Jiménez, A., de Vries, A. P. J., Torres, A., Gaspari, F., & Remuzzi, G. (2019) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0080-9 · Cited by 294
Chronic Kidney Disease: Detection and Evaluation
Raena M. Pettitt, D., Alonna P. Brumbaugh, O.-I., Michaela F. Gartman, O.-I., & Alyssa M. Jackson, O.-I. (2020) · Osteopathic Family Physician · doi:10.33181/12011 · Cited by 192
Comparing GFR estimating equations using cystatin C and creatinine in elderly individuals
Fan, L., Levey, A. S., Gudnason, V., Eiriksdottir, G., Andresdottir, M. B., Gudmundsdottir, H., Indridason, O. S., Palsson, R., Mitchell, G., & Inker, L. A. (2015) · Journal of the American Society of Nephrology · doi:10.1681/asn.2014060607 · Cited by 170
“0) 10 (35) 51 (18) 88 (19) 4 (12) Scr (mg/dl) 1.”
Self-citation
Metadata
- Authors
- Fan, L., Inker, L. A., Rossert, J., Froissart, M., Rossing, P., Mauer, M., & Levey, A. S.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-01-20
- Volume
- 29
- Issue
- 6
- Pages
- 1195-1203
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2120361346
- Cited by
- 101
- References
- 3
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glomerular filtration rate estimation using cystatin C alone or combined with creatinine as a confirmatory test. https://app.cochat.ai/papers/10.1093/ndt/gft509
- The paper
- Fan, L., Inker, L. A., Rossert, J., Froissart, M., Rossing, P., Mauer, M., & Levey, A. S. (2014). Glomerular filtration rate estimation using cystatin C alone or combined with creatinine as a confirmatory test. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gft509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.