A low-swelling hydrogel as a multirole sealant for efficient dural defect sealing and prevention of postoperative adhesion
The DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
Dural defects and subsequent complications, including cerebrospinal fluid (CSF) leakage, are common in both spine surgery and neurosurgery, and existing clinical treatments are still unsatisfactory. In this study, a tissue-adhesive and low-swelling hydrogel sealant comprising gelatin and o-phthalaldehyde (OPA)-terminated 4-armed poly(ethylene glycol) (4aPEG-OPA) is developed via the OPA/amine condensation reaction. The hydrogel shows an adhesive strength of 79.9 ± 12.0 kPa on porcine casing and a burst pressure of 208.0 ± 38.0 cmH2O. The hydrogel exhibits a low swelling ratio at physiological conditions, avoiding nerve compression in the limited spinal and intracranial spaces. In rat and rabbit models of lumbar and cerebral dural defects, the 4aPEG-OPA/gelatin hydrogel achieves excellent performance in dural defect sealing and preventing CSF leakage. Moreover, local inflammation, epidural fibrosis and postoperative adhesion in the defect areas are markedly reduced. Thus, these findings establish the strong potential of the hydrogel sealant for the effective watertight closure of dural defects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Defects of the dura disrupt the homeostasis of CSF, which results in leakage of CSF and an increase in the risk of secondary brain injury (Cheng et al., 2024).”
From Complex bioactive nanofibrous dura mater repairs traumatic brain injury (2026) · cites this paper as Cheng et al., 2024
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Self-citationQu, J., Zhao, X., Liang, Y., Zhang, T., Ma, P. X., & Guo, B. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.08.044 · Cited by 1,809
Tough adhesives for diverse wet surfaces
Li, J., Celiz, A. D., Yang, J., Yang, Q., Wamala, I., Whyte, W., Seo, B. R., Vasilyev, N. V., Vlassak, J. J., Suo, Z., et al. (2017) · Science · doi:10.1126/science.aah6362 · Cited by 1,598
Dry double-sided tape for adhesion of wet tissues and devices
Yuk, H., Varela, C. E., Nabzdyk, C. S., Mao, X., Padera, R. F., Roche, E. T., & Zhao, X. (2019) · Nature · doi:10.1038/s41586-019-1710-5 · Cited by 1,471
Gelatin: A Valuable Protein for Food and Pharmaceutical Industries: Review
Djagny, K. B., Wang, Z., & Xu, S. (2001) · Critical Reviews in Food Science and Nutrition · doi:10.1080/20014091091904 · Cited by 554
Cui, C., Fan, C., Wu, Y., Xiao, M., Wu, T., Zhang, D., Chen, X., Liu, B., Xu, Z., Qu, B., et al. (2019) · Advanced Materials · doi:10.1002/adma.201905761 · Cited by 542
Self-citationRecent advances in the use of gelatin in biomedical research
Su, K., & Wang, C. (2015) · Biotechnology Letters · doi:10.1007/s10529-015-1907-0 · Cited by 461
Overcoming the translational barriers of tissue adhesives
Taboada, G. M., Yang, K., Pereira, M. J. N., Liu, S. S., Hu, Y., Karp, J. M., Artzi, N., & Lee, Y. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0171-7 · Cited by 449
On being the right (cell) size
Ginzberg, M. B., Kafri, R., & Kirschner, M. (2015) · Science · doi:10.1126/science.1245075 · Cited by 421
Research works printed but not linked: 3
- Zhu, 2022, High efficacy of tetra-PEG hydrogel sealants for sutureless dural closure, Bioact Mater, 8, 12
- Li, 2022, A hydrogel spinal dural patch with potential anti-inflammatory, pain relieving and antibacterial effects, Bioact Mater, 14, 389
- Terasaka, 2006, Fibrin glue and polyglycolic acid nonwoven fabric as a biocompatible dural substitute, Neurosurgery, 58, 134
Cited by
Complex bioactive nanofibrous dura mater repairs traumatic brain injury
Chen, S., Zhang, X., Guo, Q., Yan, Y., Fu, M., Wang, Y., & Wu, T. (2026) · Neural Regeneration Research · doi:10.4103/nrr.nrr-d-25-00621 · Cited by 3
Metadata
- Authors
- Cheng, X., Zhang, Z., Ren, H., Zou, Z., Zhang, Y., Qu, Y., Chen, X., Zhao, J., & He, C.
- Affiliations
- CAS Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences , Changchun 130022 , China
- Department of Orthopedics, The Second Norman Bethune Hospital of Jilin University , Changchun 130014 , China
- ORCID
- He, Chaoliang
- Venue
- National Science Review
- Publisher
- Oxford University Press (OUP)
- Published
- 2024-04-30
- Volume
- 11
- Issue
- 6
- ISSN
- 2095-5138
- 2053-714X
- Cited by
- 59
- References
- 73
- Language
- en
- Funders
- National Natural Science Foundation of China (52173147, 51973218, 22105198)
- Changchun Science and Technology Bureau (21ZGY23)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.