A New Colorimetric Method for the Determination of Free Fatty Acids with Acyl-CoA Synthetase and Acyl-CoA Oxidase1
The DOI matches its Crossref record.
Abstract
A rapid and sensitive spectrophotometric assay for free fatty acids using acyl-CoA synthetase and acyl-CoA oxidase is described. It is sensitive to as low as 5 nmol of free fatty acids, and the standard curve is linear up to 100 nmol. The assay consists of the measurement of H2O2 produced from free fatty acids by acyl-CoA synthetase and acyl-CoA oxidase. The quantity of H2O2 is determined by the absorbance at 550 nm in the presence of catalase and 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole (AHMT). This method shows a broad specificity to long-chain fatty acids and the recoveries of added fatty acids (C12-C18) are more than 90%. The presence or absence of serum components or Escherichia coli cell-free extracts has no significant effect on the recovery of added palmitic acid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dagogo-Jack, S. E., Craft, S., & Cryer, P. E. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116302 · Cited by 471
Banarer, S., McGregor, V. P., & Cryer, P. E. (2002) · Diabetes · doi:10.2337/diabetes.51.4.958 · Cited by 194
Craft, S., Dagogo-Jack, S. E., Wiethop, B. V., Murphy, C., Nevins, R. T., Fleischman, S., Rice, V., Newcomer, J. W., & Cryer, P. E. (1993) · Behavioral Neuroscience · doi:10.1037/0735-7044.107.6.926 · Cited by 191
Sleep-Related Hypoglycemia-Associated Autonomic Failure in Type 1 Diabetes
Banarer, S., & Cryer, P. E. (2003) · Diabetes · doi:10.2337/diabetes.52.5.1195 · Cited by 187
“Serum nonesterified fatty acid (20) and blood -hydroxybutyrate (21), lactate (22), and alanine (23) were measured with enzymatic methods.”
Raju, B., & Cryer, P. E. (2005) · Diabetes · doi:10.2337/diabetes.54.3.757 · Cited by 155
“Serum nonesterified fatty acids (39) and blood”
DeRosa, M. A., & Cryer, P. E. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00539.2003 · Cited by 126
“Serum nonesterified fatty acids (NEFA) were measured with an enzymatic colorimetric method (22) and blood lactate (24), -hydroxybutyrate (29) and alanine (2) with enzymatic techniques.”
MethodAttenuation of Counterregulatory Responses to Recurrent Hypoglycemia by Active Thalamic Inhibition
Arbelaez, A. M., Powers, W. J., Videen, T. O., Price, J. L., & Cryer, P. E. (2008) · Diabetes · doi:10.2337/db07-1329 · Cited by 92
“Serum nonesterified fatty acid (22) and blood lactate (23) concentrations were measured with enzymatic techniques.”
McGregor, V. P., Banarer, S., & Cryer, P. E. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00447.2001 · Cited by 56
Hypoinsulinemia is not critical to glucose recovery from hypoglycemia in humans
Heller, S. R., & Cryer, P. E. (1991) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1991.261.1.e41 · Cited by 26
Dagogo‐Jack, S., Askari, H., Morrill, B., Lehner, L. L., Kim, B., & Sha, X. (2000) · Diabetes, Obesity and Metabolism · doi:10.1046/j.1463-1326.2000.00109.x · Cited by 23
Metadata
- Authors
- HOSAKA, K., KIKUCHI, T., MITSUHIDA, N., & KAWAGUCHI, A.
- Venue
- The Journal of Biochemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1981-04
- Volume
- 89
- Issue
- 6
- Pages
- 1799-1803
- ISSN
- 0021-924X (ISSN-L)
- 1756-2651
- OpenAlex
- W2136356529
- Cited by
- 65
- References
- 0
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.