The Application of Generalizability Theory to Reliability Assessment: An Illustration Using Isometric Force Measurements
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: The objective of this study was to examine the potential use of the generalizability theory for assessing reliability of muscle force measurements in clinical applications. Reliability is expressed in terms of standard error of measurement (SEM) and the indexes derived from the SEM. Using generalizability theory, potential sources of measurement error can be recognized and estimated. SUBJECTS: Ten healthy women, aged 23 to 47 years (means = 29.5, SD = 7.1), participated in the study. METHODS: The method is illustrated by presenting a pilot study. Repeated measurements of maximal isometric knee extension force were carried out by two therapists. The time interval between measurement occasions was 1 week. A functional prototype of a hand-held dynamometer was used, and measurements were carried out according to standardized test protocols. RESULTS: Relatively important sources of measurement error were associated with interaction effects between subject and therapist as well as with interactions including the factor occasion. The SEM of the net knee moment was estimated for various hypothetical applications of the dynamometer. CONCLUSION AND DISCUSSION: It is concluded that the SEM, the corresponding confidence interval, and the smallest detectable difference are practical measures for expressing reliability of measurements on an individual. Generalizability theory is a powerful tool for estimating the magnitude of multiple sources of measurement error and for assessing the reliability of measurements tailored to specific clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Searle, S. R., & Searle, S. R. (1971) · Cited by 3,229
Measuring change over time: Assessing the usefulness of evaluative instruments
Guyatt, G., Walter, S., & Norman, G. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90069-5 · Cited by 1,880
CONSIDERATIONS IN THE CHOICE OF INTEROBSERVER RELIABILITY ESTIMATES
Hartmann, D. P. (1977) · Journal of Applied Behavior Analysis · doi:10.1901/jaba.1977.10-103 · Cited by 762
The biomechanics of human movement
(1991) · Applied Ergonomics · doi:10.1016/0003-6870(91)90404-6 · Cited by 739
Psychological statistics, 2nd ed.
McNemar, Q. (1955) · Cited by 559
Mitchell, S. K. (1979) · Psychological Bulletin · doi:10.1037//0033-2909.86.2.376 · Cited by 445
A Proposed Standard Procedure for Static Muscle Strength Testing
Caldwell, L. S., Chaffin, D. B., Dukes‐Dobos, F. N., Kroemer, K. H. E., Laubach, L. L., Snook, S. H., & Wasserman, D. E. (1974) · American Industrial Hygiene Association Journal · doi:10.1080/0002889748507023 · Cited by 423
Interrater Reliability of Hand-Held Dynamometry
Bohannon, R. W., & Andrews, A. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.6.931 · Cited by 315
Cited by
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
“• There is an extensive theoretical base for reliability, the most developed form of which is known as generalisability theory.[5,6] Variances”
BackgroundAtkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Responsiveness of the Numeric Pain Rating Scale in Patients with Low Back Pain
Childs, J. D., Piva, S. R., & Fritz, J. M. (2005) · Spine · doi:10.1097/01.brs.0000164099.92112.29 · Cited by 1,481
Fritz, J. M., & Irrgang, J. J. (2001) · Physical Therapy · doi:10.1093/ptj/81.2.776 · Cited by 1,045
Smallest real difference, a link between reproducibility and responsiveness
Beckerman, H., Roebroeck, M. E., Lankhorst, G. J., Becher, J. G., Bezemer, P. D., & Verbeek, A. L. M. (2001) · Quality of Life Research · doi:10.1023/a:1013138911638 · Cited by 857
Self-citationWyrwich, K. W., Nienaber, N. A., Tierney, W. M., & Wolinsky, F. D. (1999) · Medical Care · doi:10.1097/00005650-199905000-00006 · Cited by 569
Chen, H.-M., Chen, C. C., Hsueh, I.-P., Huang, S.-L., & Hsieh, C.-L. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308331146 · Cited by 445
Koppenhaver, S. L., Hebert, J. J., Fritz, J. M., Parent, E. C., Teyhen, D. S., & Magel, J. S. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.06.022 · Cited by 300
Responsiveness of the Neck Disability Index in patients with mechanical neck disorders
Young, B. A., Walker, M. J., Strunce, J. B., Boyles, R. E., Whitman, J. M., & Childs, J. D. (2009) · The Spine Journal · doi:10.1016/j.spinee.2009.06.002 · Cited by 284
Deficit and change in gait velocity during rehabilitation after stroke
Goldie, P. A., Matyas, T. A., & Evans, O. M. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90072-6 · Cited by 268
Rehabilitative Ultrasound Imaging of the Abdominal Muscles
Teyhen, D. S., Gill, N. W., Whittaker, J. L., Henry, S. M., Hides, J. A., & Hodges, P. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2558 · Cited by 265
Cook, J., Hislop, J., Adewuyi, T., Harrild, K., Altman, D., Ramsay, C., Fraser, C., Buckley, B., Fayers, P., Harvey, I., et al. (2014) · Health Technology Assessment · doi:10.3310/hta18280 · Cited by 194
Recording scapular motion using an acromion marker cluster
van Andel, C., van Hutten, K., Eversdijk, M., Veeger, D., & Harlaar, J. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.07.012 · Cited by 189
Self-citationRietberg, M. B., Van Wegen, E. E. H., & Kwakkel, G. (2010) · Disability and Rehabilitation · doi:10.3109/09638281003734458 · Cited by 165
“96 6 2 6 SEM to indicate 95% confidence for real change between the two assessments scores [37].”
BackgroundKropmans, T. J. B., Dijkstra, P. U., Stegenga, B., Stewart, R., & de Bont, L. G. M. (1999) · Journal of Dental Research · doi:10.1177/00220345990780031101 · Cited by 126
“Instruments measuring function impairment are scarce (Schiffman, 1992; Murakami, 1992; Stegenga et al, 1993).”
Backgroundvon Piekartz, H., & Lüdtke, K. (2011) · CRANIO® · doi:10.1179/crn.2011.008 · Cited by 114
Koo, T. K., Cohen, J. H., & Zheng, Y. (2011) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2011.05.009 · Cited by 16
Metadata
- Authors
- Roebroeck, M. E., Harlaar, J., & Lankhorst, G. J.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-06-01
- Volume
- 73
- Issue
- 6
- Pages
- 386-395
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2127843731
- Cited by
- 228
- References
- 22
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.