Heart rate variability measurements and the prediction of ventricular arrhythmias
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
From the Department of Emergency Medicine, Royal Infirmary of Edinburgh, Edinburgh, and 1Cardiodigital Ltd, Elvingston Science Centre, Gladsmuir, UK Heart rate variability (HRV) is the temporal variation between sequences of consecutive heartbeats. On a standard electrocardiogram (ECG), the maximum upwards deflection of a normal QRS complex is at the peak of the R wave (Figure 1), and the duration between two adjacent R wave peaks is termed the R-R interval. The ECG signal requires editing before HRV analysis can be performed, a process requiring the removal of all non-sinus-node-originating beats. The resulting period between adjacent QRS complexes resulting from sinus node depolarizations is termed the N-N (normal-normal) interval.1 HRV is the measurement of the variability of the N-N intervals. ... Although counter-intuitive, it is possible that HRV confers a survival advantage. Any system exhibiting intrinsic variability is primed to respond rapidly and appropriately to demands placed upon it. HRV is a measure of the balance between sympathetic mediators of heart rate (HR) (i.e. the effect of epinephrine and norepinephrine, released from sympathetic nerve fibres, acting on the sino-atrial and atrio-ventricular nodes), which increase the rate of cardiac contraction and facilitate conduction at the atrio-ventricular node, and parasympathetic mediators of HR (i.e. the influence of acetylcholine, released by the parasympathetic nerve fibres, acting on the sino-atrial and atrio-ventricular nodes), leading to a decrease in the HR and a slowing of conduction at the atrio-ventricular node. Sympathetic mediators appear to exert their influence over longer time periods and are reflected in the low frequency power (LFP) of the HRV spectrum (between 0.04 Hz and 0.15 Hz.2,3 Vagal mediators exert their influence more quickly on the heart, and principally affect the high frequency power (HFP) of the HRV spectrum (between 0.15 Hz and 0.4 Hz).4 Thus, at any point in time, the LFP:HFP ratio is a proxy for the sympatho-vagal balance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995 · cited 6×
“Signal quality and elimination of background ‘noise’ is important when analysing HRV. Interpretation of HRV is extremely difficult in patients who are not in sinus rhythm (e.g. atrial fibrillation), or those with an extremely irregular HR (Figure 3) or multiple ectopic (VE) beats.”
BackgroundInfluentialCardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569 · cited 2×
“Higher LFP occurs in the daytime, and higher HFP at night.(5,6) Markers of vagal activity (RMSSD and HFP) display circadian variability and are maximal during sleep.”
BackgroundAssessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876 · cited 1×
“15Hz.(2,3) Vagal mediators exert their influence more quickly on the heart, and principally affect the high frequency power (HFP) of the HRV spectrum (between 0.”
BackgroundFrequency domain measures of heart period variability and mortality after myocardial infarction
Bigger, J. T., Fleiss, J. L., Steinman, R. C., Rolnitzky, L. M., Kleiger, R. E., & Rottman, J. N. (1992) · Circulation · doi:10.1161/01.cir.85.1.164 · Cited by 1,712
Cited by
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
“Rather than consider the local morphology of the whole ECG signal, many researchers have focused on the longer term temporal variability of the heartbeat, the analysis of which allows an assessment of autonomous nervous system activity (Reed et al 2005).”
BackgroundSelf-citationFlexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Improvements in heart rate variability with exercise therapy
Routledge, F. S., Campbell, T. S., McFetridge-Durdle, J. A., & Bacon, S. L. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70395-0 · Cited by 381
“HRV is the beat-to-beat variation in time of consecutive heartbeats expressed in normal sinus rhythm on electrocardiogram recordings, ranging from a few minutes to 24 h (10-12).”
BackgroundCardiac rehabilitation outcomes following a 6-week program of PCI and CABG Patients
Jelinek, H. F., Huang, Z. Q., Khandoker, A. H., Chang, D., & Kiat, H. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00302 · Cited by 339
The role of heart rate variability in sports physiology
DONG, J.-G. (2016) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2016.3104 · Cited by 319
Metadata
- Authors
- Reed, M. J., Robertson, C. E., & Addison, P. S.
- Venue
- QJM
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-01-25
- Volume
- 98
- Issue
- 2
- Pages
- 87-95
- ISSN
- 0033-5622 (ISSN-L)
- 1460-2725
- 1460-2393
- OpenAlex
- W2054676932
- Cited by
- 181
- References
- 7
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.