Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels
Open accessThe DOI matches its Crossref record.
Abstract
Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Establishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186
Diagnostic reference levels from the ACR CT accreditation program
McCollough, C., Branham, T., Herlihy, V., Bhargavan, M., Robbins, L., Bush, K., McNitt-Gray, M., Payne, J. T., Ruckdeschel, T., Pfeiffer, D., et al. (2011) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2011.03.014 · Cited by 98
Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
Salama, D. H., Vassileva, J., Mahdaly, G., Shawki, M., Salama, A., Gilley, D., & Rehani, M. M. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.050 · Cited by 98
Bos, D., Yu, S., Luong, J., Chu, P., Wang, Y., Einstein, A. J., Starkey, J., Delman, B. N., Duong, P.-A. T., Das, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08266-1 · Cited by 64
Metadata
- Authors
- Treier, R., Aroua, A., Verdun, F. R., Samara, E., Stuessi, A., & Trueb, P. R.
- Venue
- Radiation Protection Dosimetry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-10-06
- Volume
- 142
- Issue
- 2-4
- Pages
- 244-254
- ISSN
- 0144-8420 (ISSN-L)
- 1742-3406
- OpenAlex
- W2073810350
- Cited by
- 143
- References
- 0
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels. https://app.cochat.ai/papers/10.1093/rpd/ncq279
- The paper
- Treier, R., Aroua, A., Verdun, F. R., Samara, E., Stuessi, A., & Trueb, P. R. (2010). Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncq279
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.