Cited by 186Radiation Dose and ImagingAdvanced Radiotherapy TechniquesRadiology practices and education

Establishment of CT diagnostic reference levels in Ireland

Open access
Foley, S J, McEntee, M F, Rainford, L A·2012·The British Journal of Radiology

Abstract

OBJECTIVE: To propose Irish CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. METHODS: A pilot study investigated the most frequent CT examinations. 40 CT sites were then asked to complete a survey booklet to allow the recording of CT parameters for each of 9 CT examinations during a 12-week period. Dose data [CT volume index (CTDI(vol)) and dose-length product (DLP)] on a minimum of 10 average-sized patients in each category were recorded to calculate a mean site CTDI(vol) and DLP value. The rounded 75th percentile was used to calculate a DRL for each site and the country by compiling all results. RESULTS: are compared with international DRL data. Results Data were collected for 3305 patients. 30 sites responded with data for 34 scanners, representing 54% of the national total. All equipment had multislice capability (2-128 slices). DRLs are proposed using CTDI(vol) (mGy) and DLP (mGy cm) for CT head (66/58 and 940, respectively), sinuses (16 and 210, respectively), cervical spine (19 and 420, respectively), thorax (9/11 and 390, respectively), high resolution CT (7 and 280, respectively), CT pulmonary angiography (13 and 430, respectively), multiphase abdomen (13 and 1120, respectively), routine abdomen/pelvis (12 and 600, respectively) and trunk examinations (10/12 and 850, respectively). These values are lower than current DRLs and comparable to other international studies. Wide variations in mean doses are noted across sites. CONCLUSIONS: Baseline figures for Irish CT DRLs are provided on the most frequently performed CT examinations. The variations in dose between CT departments as well as between identical scanners suggest a large potential for optimisation of examinations.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/bjr/15839549

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Foley, S. J., McEntee, M. F., & Rainford, L. A.
Affiliations
  • University College Dublin (IE)
  • The University of Sydney (AU)
Venue
The British Journal of Radiology
Published
2012-10
Volume
85
Issue
1018
Pages
1390-1397
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2035839552
Cited by
186
References
19
Citations by year
2026: 8 · 2025: 19 · 2024: 17 · 2023: 14 · 2022: 18 · 2021: 11 · 2020: 21 · 2019: 12 · 2018: 20 · 2017: 14 · 2016: 9 · 2015: 15 · 2014: 3 · 2013: 4 · 2012: 1
FWCI
5.51
Type
journal article
Language
en
Open access
Locations
  • British Journal of Radiology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Research Repository UCD (University College Dublin) (submittedVersion, cc-by-nc-nd)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
radiation dose, dose-length product, CT pulmonary angiography, multidetector computed tomography, dose optimization, Ireland
MeSH terms
Humans, Ireland, Pilot Projects, Radiation Dosage, Reference Values, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review