Cited by 98Radiation Dose and ImagingAdvanced Radiotherapy TechniquesRadiology practices and education

Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt

Salama, Dina Husseiny, Vassileva, Jenia, Mahdaly, Gamal, Shawki, Mona, Salama, Ahmad, Gilley, Debbie, Rehani, Madan Mohan·2017·Physica Medica

Abstract

Objectives To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization.Methods Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France.Results The Egyptian DRLs for CTDI vol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy.cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDI vol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDI vol. For abdomen and abdomen-pelvis DRLs for CTDI vol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries.Conclusion Despite lower DRLs for CTDI vol, an important consistent problem appears to be higher scan range as DRLs for DLP are higher.

Integrity signals

Registry

Crossref · 10.1016/j.ejmp.2017.05.050

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Egypt's key findings revealed a consistent problem of higher CT scan ranges of the DRLs for DLP despite the lower DRLs for volume-weighted CTDI.

    “Egypt is one of the few African countries to have developed the National DRL. Their key findings revealed a consistent problem of higher CT scan ranges of the DRLs for DLP despite the lower DRLs for volume-weighted CTDI [15].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Salama, D. H., Vassileva, J., Mahdaly, G., Shawki, M., Salama, A., Gilley, D., & Rehani, M. M.
Affiliations
  • Egyptian Atomic Energy Authority (EG)
  • International Atomic Energy Agency (AT)
  • Alexandria University (EG)
  • Ain Shams University (EG)
  • Harvard University (US)
Corresponding author
Salama, Dina Husseiny
Venue
Physica Medica
Publisher
Elsevier BV
Published
2017-07
Volume
39
Pages
16-24
ISSN
1120-1797 (ISSN-L)
OpenAlex
W2670497016
Cited by
98
References
18
Citations by year
2026: 7 · 2025: 17 · 2024: 16 · 2023: 9 · 2022: 14 · 2021: 14 · 2020: 15 · 2019: 4 · 2018: 2
FWCI
4.40
Type
journal article
Language
en
Open access
closed
Locations
  • Physica Medica (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministeriet Sundhed Forebyggelse
  • Egyptian Society of Radiology and Nuclear Medicine
  • International Atomic Energy Agency
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
diagnostic reference levels, computed tomography, radiation dose optimization, CTDIvol, DLP, head CT, chest CT, abdominal CT, CT angiography, Egypt, scan range
MeSH terms
Egypt, Humans, Radiation Dosage, Reference Values, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review