Snoring: Is It in the Ear of the Beholder?
The DOI matches its Crossref record.
Abstract
Summary: Complaint of snoring, which is usually voiced by a patient's bedpartner, frequently leads to investigations in the sleep laboratory that are designed to assess snoring objectively and determine whether it is a symptom of sleep apnea. How well this subjective complaint of the listener is confirmed by the objective measurement of snoring is not known. Consequently, we designed a study i) to test the validity of self-perception of snoring and ii) to compare subjective perception of snoring by the sleep technologist with objective measurement of its frequency and loudness. We studied 613 unselected patients referred to our sleep clinic because of snoring and suspicion of sleep apnea. They all had nocturnal polysomnography that included measurements of snoring, expressed as the number of snores per hour of sleep [snoring index (SI)] and mean (dBmean) and maximum (dBmax) nocturnal sound intensity. Following the sleep study, the technologist (and patient) independently rated a patient's snoring as none, mild, moderate or severe. Kruskall-Wallis test, Spearman rank correlations and Cohen's kappa statistics were used to compare the groups, examine the correlations between subjective and objective measurements, and check the agreement between them. We found that i) most patients who snore (471 of 613) were unaware of this behavior; ii) snoring index increased progressively from the “none” group (median SI = 26) to the “severe” group (median SI = 755), with a significant but moderate correlation between the technologist's impression and SI (r = 0.68, p < 0.0005) and poor correlation between the technologist's impression and dBmean (r = 0.34, p < 0.0005); and iii) most of those patients who claim to be able to judge the severity of their snoring have a different perception of it than the listener, with poor agreement between patient's and technologist's subjective impression (Cohen's kappa = 0.22, 95% confidence limits: 0.14−0.33). We conclude that to a large extent snoring is “in the ear of the beholder”, showing only moderate correlation with objective measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Radiofrequency Volumetric Tissue Reduction of the Palate in Subjects With Sleep-Disordered Breathing
Powell, N. B., Riley, R. W., Troell, R. J., Li, K., Blumen, M. B., & Guilleminault, C. (1998) · Chest · doi:10.1378/chest.113.5.1163 · Cited by 330
A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea Treatment
BLOCH, K. E., ISELI, A., ZHANG, J. N., XIE, X., KAPLAN, V., STOECKLI, P. W., & RUSSI, E. W. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9908112 · Cited by 223
Clinical presentations of obstructive sleep apnea syndrome
Skomro, R. P., & Kryger, M. H. (1999) · Progress in Cardiovascular Diseases · doi:10.1053/pcad.1999.0410331 · Cited by 78
Treatments for Snoring: A Comparison of Somnoplasty and an Oral Appliance
Cartwright, R., Venkatesan, T. K., Caldarelli, D., & Diaz, F. (2000) · The Laryngoscope · doi:10.1097/00005537-200010000-00020 · Cited by 30
Radiofrequency Tissue Volume Reduction: Multilesion vs Single-Lesion Treatments for Snoring
Ferguson, M., Smith, T. L., Zanation, A. M., & Yarbrough, W. G. (2001) · Archives of Otolaryngology–Head & Neck Surgery · doi:10.1001/archotol.127.9.1113 · Cited by 20
Metadata
- Authors
- Hoffstein, V., Mateika, S., & Anderson, D.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-09-01
- Volume
- 17
- Issue
- 6
- Pages
- 522-526
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2225016836
- Cited by
- 131
- References
- 0
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Snoring: Is It in the Ear of the Beholder? https://app.cochat.ai/papers/10.1093/sleep/17.6.522
- The paper
- Hoffstein, V., Mateika, S., & Anderson, D. (1994). Snoring: Is It in the Ear of the Beholder? Sleep. https://doi.org/10.1093/sleep/17.6.522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.