CoChat

Nasal Continuous Positive Airway Pressure Treatment: Current Realities and Future

Open access
Berthon-Jones, Michael, Lawrence, Sue, Sullivan, Colin E., Grunstein, Ron · 1996 · Sleep
Cited by 74

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Nasal continuous positive airway pressure (CPAP) is a highly effective treatment for obstructive sleep apnea syndrome. The apnea/hypopnea index (AHI) is reduced 10-fold, but the patient dropout rate is up to 30%, and usage is typically < 5 hours per night. Titration, designed to make the best trade-off between effectiveness and side effects, is expensive. Autotitrating devices make this trade-off on a minute-by-minute basis, potentially reducing mean pressure delivery, reducing side effects, and increasing compliance. The aim of this study was to test the effectiveness of the AutoSet self-adjusting nasal CPAP system (ResMed, Sydney, Australia) in eliminating obstructive events and normalizing the arousal index. Forty-five subjects (41 males and 4 females with AHI) values of > 20/hour were recruited, with written informed consent. Subjects slept for a diagnostic night, followed by a treatment night, in the laboratory, using the AutoSet system with full polysomnographic monitoring of respiratory and sleep variables. Arousals were scored using ASDA criteria. Hypopneas were scored when there was a 50% reduction in ventilation for > 10 seconds, associated with a 4% drop in oxygen saturation. For comparison, the ASDA arousal index in 16 normal subjects (without nasal CPAP) is provided. Results are given as mean +/- standard error of the mean. AHI was reduced from 55 +/- 3 to 1.5 +/- 0.35 events/hour (p < 0.0001). The arousal index was reduced from 65 +/- 3 to 18 +/- 2 events/hour (p < 0.0001), identical to the value in the 16 healthy normal subjects. There was a 158% +/- 21% increase in slow-wave sleep (p = 0.01) and a 186% +/- 27% increase in rapid eye movement sleep (p = 0.013). The AutoSet self-adjusting nasal CPAP system adequately treats obstructive sleep apnea syndrome on the first night under laboratory conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/19.suppl_9.s131

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 74

Metadata

Authors
Berthon-Jones, M., Lawrence, S., Sullivan, C. E., & Grunstein, R.
Venue
Sleep
Published
1996-11
Volume
19
Issue
suppl_9
Pages
S131-S135
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2282218130
Cited by
74
References
1
FWCI
3.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nasal Continuous Positive Airway Pressure Treatment: Current Realities and Future. https://app.cochat.ai/papers/10.1093/sleep/19.suppl_9.s131
The paper
Berthon-Jones, M., Lawrence, S., Sullivan, C. E., & Grunstein, R. (1996). Nasal Continuous Positive Airway Pressure Treatment: Current Realities and Future. Sleep. https://doi.org/10.1093/sleep/19.suppl_9.s131

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.