Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record.

Detection of Respiratory Events During NPSG: Nasal Cannula/Pressure Sensor Versus Thermistor

· 1997 · Sleep

Abstract

Recording of respiratory airflow is an integral part of polysomnography (NPSG). It is conventionally monitored with a thermistor that measures temperature as a surrogate of flow. The subjectivity of interpreting hypopnea from this signal has prompted us to measure nasal airflow directly with a simple pneumotachograph consisting of a standard nasal cannula connected to a 2-cm H2O pressure transducer. We manually analyzed respiratory events using simultaneous thermistor and nasal cannula in 11 patients with obstructive sleep apnea syndrome (OSAS) and 9 with upper airway resistance syndrome (UARS). Definite events were scored separately for each signal when amplitude was <50% for >10 seconds. Events were also scored on the nasal cannula signal when the flattened shape of the signal suggested flow limitation, and these were tabulated separately. Definite events in one signal were tabulated by whether the other signal showed a definite event or not. In addition, nasal cannula events were compared to a more liberal thermistor criterion (any change in the signal for > or = 2 breaths). Visually, events were more easily recognized on the nasal cannula signal than on the thermistor signal. In OSAS, 1,873 definite thermistor events were detected. Of these, 99.1% were detected by nasal cannula, and 0.9% were missed. Of 3,541 definite nasal cannula events, 51.9% were detected by definite thermistor criteria; 75.0% were detected by liberal thermistor criteria; 25.0% were missed. In UARS, 123 definite thermistor events were detected. Of these, 89.4% were detected by nasal cannula and 10.6% were missed. Nine hundred and three nasal cannula events were detected. However, only 17.2% of these were detected by definite thermistor criteria; 38.6% were detected by liberal thermistor criteria; 61.4% were completely undetected by thermistor. When events identified on the nasal cannula by flow limitation alone were excluded, the thermistor detected 30.1% of events by definite criteria and 78.6% by liberal criteria, still leaving 21.4% completely undetected by the thermistor. We conclude that the nasal cannula reliably detects respiratory events seen by thermistor. Additional events (including some characterized only by flow limitation) that help define the UARS, were recognized by nasal cannula but often completely missed by thermistor. We propose that respiratory monitoring during NPSG with nasal cannula significantly improves event detection and classification over that with thermistor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/20.12.1175

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 237

Metadata

Venue
Sleep
Published
1997-12-01
Volume
20
Issue
12
Pages
1175-84
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W1606927834
Cited by
237
References
0
FWCI
4.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Respiratory Events During NPSG: Nasal Cannula/Pressure Sensor Versus Thermistor. https://app.cochat.ai/papers/10.1093/sleep/20.12.1175
The paper
Detection of Respiratory Events During NPSG: Nasal Cannula/Pressure Sensor Versus Thermistor. (1997). Sleep. https://doi.org/10.1093/sleep/20.12.1175

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.