Abstract
Recording of respiratory airflow is an integral part of polysomnography (NPSG). It is conventionally monitored with a thermistor that measures temperature as a surrogate of flow. The subjectivity of interpreting hypopnea from this signal has prompted us to measure nasal airflow directly with a simple pneumotachograph consisting of a standard nasal cannula connected to a 2-cm H2O pressure transducer. We manually analyzed respiratory events using simultaneous thermistor and nasal cannula in 11 patients with obstructive sleep apnea syndrome (OSAS) and 9 with upper airway resistance syndrome (UARS). Definite events were scored separately for each signal when amplitude was <50% for >10 seconds. Events were also scored on the nasal cannula signal when the flattened shape of the signal suggested flow limitation, and these were tabulated separately. Definite events in one signal were tabulated by whether the other signal showed a definite event or not. In addition, nasal cannula events were compared to a more liberal thermistor criterion (any change in the signal for > or = 2 breaths). Visually, events were more easily recognized on the nasal cannula signal than on the thermistor signal. In OSAS, 1,873 definite thermistor events were detected. Of these, 99.1% were detected by nasal cannula, and 0.9% were missed. Of 3,541 definite nasal cannula events, 51.9% were detected by definite thermistor criteria; 75.0% were detected by liberal thermistor criteria; 25.0% were missed. In UARS, 123 definite thermistor events were detected. Of these, 89.4% were detected by nasal cannula and 10.6% were missed. Nine hundred and three nasal cannula events were detected. However, only 17.2% of these were detected by definite thermistor criteria; 38.6% were detected by liberal thermistor criteria; 61.4% were completely undetected by thermistor. When events identified on the nasal cannula by flow limitation alone were excluded, the thermistor detected 30.1% of events by definite criteria and 78.6% by liberal criteria, still leaving 21.4% completely undetected by the thermistor. We conclude that the nasal cannula reliably detects respiratory events seen by thermistor. Additional events (including some characterized only by flow limitation) that help define the UARS, were recognized by nasal cannula but often completely missed by thermistor. We propose that respiratory monitoring during NPSG with nasal cannula significantly improves event detection and classification over that with thermistor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sher, A. E., Schechtman, K. B., & Piccirillo, J. F. (1996) · Sleep · doi:10.1093/sleep/19.2.156 · Cited by 1,335
The Sleep Heart Health Study: Design, Rationale, and Methods
(1997) · Sleep · doi:10.1093/sleep/20.12.1077 · Cited by 1,331
Self-citation
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
The new AASM criteria for scoring hypopneas: impact on the apnea hypopnea index
Ruehland, W. R., Rochford, P. D., O’Donoghue, F. J., Pierce, R. J., Singh, P., & Thornton, A. T. (2009) · SLEEP · doi:10.1093/sleep/32.2.150 · Cited by 696
Wraith, J. E., Clarke, L. A., Beck, M., Kolodny, E. H., Pastores, G. M., Muenzer, J., Rapoport, D. M., Berger, K. I., Swiedler, S. J., Kakkis, E. D., et al. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.01.046 · Cited by 547
Metrics of sleep apnea severity: beyond the apnea-hypopnea index
Malhotra, A., Ayappa, I., Ayas, N., Collop, N., Kirsch, D., Mcardle, N., Mehra, R., Pack, A. I., Punjabi, N., White, D. P., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab030 · Cited by 489
“reported using a standard nasal cannula connected to a pressure transducer to detect airflow [21].”
MethodPaper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
The upper airway in sleep: physiology of the pharynx
Ayappa, I., & Rapoport, D. M. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0238 · Cited by 340
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Detection of Flow Limitation with a Nasal Cannula/ Pressure Transducer System
HOSSELET, J.-J., NORMAN, R. G., AYAPPA, I., & RAPOPORT, D. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.5.9708008 · Cited by 301
On the rise and fall of the apnea−hypopnea index: A historical review and critical appraisal
Pevernagie, D. A., Gnidovec‐Strazisar, B., Grote, L., Heinzer, R., McNicholas, W. T., Penzel, T., Randerath, W., Schiza, S., Verbraecken, J., & Arnardottir, E. S. (2020) · Journal of Sleep Research · doi:10.1111/jsr.13066 · Cited by 297
Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome
Dingli, K., Coleman, E. L., Vennelle, M., Finch, S. P., Wraith, P. K., Mackay, T. W., & Douglas, N. J. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00298103 · Cited by 287
Stevenson, I. H., Teichtahl, H., Cunnington, D., Ciavarella, S., Gordon, I., & Kalman, J. M. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn214 · Cited by 240
Schulz, R., Blau, A., Börgel, J., Duchna, H. W., Fietze, I., Koper, I., Prenzel, R., Schädlich, S., Schmitt, J., Tasci, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00037106 · Cited by 217
“However, pressure cannulae were used for the detection of apnoeas/hypopnoeas, which are more sensitive than the thermistors used in the earlier studies [ 14 ].”
MethodObstructive Sleep Apnea Syndrome
BETTEGA, G., PÉPIN, J.-L., VEALE, D., DESCHAUX, C., RAPHAËL, B., & LÉVY, P. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9904058 · Cited by 215
“This technique has the advantage of measuring airflow during sleep in a semiquantitative way (19, 20 ).”
The Upper Airway Resistance Syndrome
Exar, E. N., & Collop, N. A. (1999) · Chest · doi:10.1378/chest.115.4.1127 · Cited by 200
Krakow, B., Melendrez, D., Pedersen, B., Johnston, L., Hollifield, M., Germain, A., Koss, M., Warner, T. D., & Schrader, R. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01087-8 · Cited by 189
Goodwin, J. L., Enright, P. L., Kaemingk, K. L., Rosen, G. M., Morgan, W. J., Fregosi, R. F., & Quan, S. F. (2001) · Sleep · doi:10.1093/sleep/24.8.937 · Cited by 175
Chowdhuri, S., Quan, S. F., Almeida, F., Ayappa, I., Batool-Anwar, S., Budhiraja, R., Cruse, P. E., Drager, L. F., Griss, B., Marshall, N., et al. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0361st · Cited by 166
Li, K. K., Powell, N. B., Riley, R. W., & Guilleminault, C. (2002) · Otolaryngology–Head and Neck Surgery · doi:10.1067/mhn.2002.126900 · Cited by 93
Obstructive sleep apnoea and oral breathing in patients free of nasal obstruction
Koutsourelakis, I., Vagiakis, E., Roussos, C., & Zakynthinos, S. (2006) · European Respiratory Journal · doi:10.1183/09031936.00058406 · Cited by 87
Calibration Model for Apnea-Hypopnea Indices: Impact of Alternative Criteria for Hypopneas
Ho, V., Crainiceanu, C. M., Punjabi, N. M., Redline, S., & Gottlieb, D. J. (2015) · Sleep · doi:10.5665/sleep.5234 · Cited by 87
Positive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Sanders, M. H., Montserrat, J. M., Farré, R., & Givelber, R. J. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-150mg · Cited by 75
Upper Airway Resistance Syndrome Is Not a Distinct Syndrome
Douglas, N. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.16158b · Cited by 67
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Hobson, J. C., Robinson, S., Antic, N. A., McEvoy, R. D., Windler, S., MacKay, S., & Carney, A. S. (2012) · The Laryngoscope · doi:10.1002/lary.23342 · Cited by 40
Rollheim, J., Tvinnereim, M., Sitek, J., & Osnes, T. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050100330 · Cited by 29
Metadata
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-12-01
- Volume
- 20
- Issue
- 12
- Pages
- 1175-84
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1606927834
- Cited by
- 237
- References
- 2
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.