CoChat

Long-term Efficacy of Fixed CPAP Recommended by Autoset® for OSAS

Gagnadoux, F, Rakotonanahary, D, de Araujo, MT Martins, Barros-Vieira, S, Fleury, B · 1999 · Sleep
Cited by 46

The DOI matches its Crossref record.

Abstract

The Autoset autotitration system (Resmed, Australia) was designed as an aid for determination of the effective level of CPAP. Two studies have shown that the 95% pressure centile during a night with Autoset, after excluding any periods with severe leak (P95), was well correlated with the pressure determined manually according to the reference method. However, the suitability of P95 under Autoset for treatment with conventional CPAP needed to be evaluated outside of the context of titration. The objective of this study was to measure the compliance and efficacy of CPAP at P95 determined by Autoset, after 3 months. Twenty-four patients who had undergone routine autotitration by Autoset under polysomnographic control in the laboratory for previously untreated OSAS were evaluated after 3 months of treatment with CPAP at P95. This evaluation was based on compliance, daily usage, determined by reading the hourly counter, Epworth sleepiness score and home respiratory recording under CPAP. Polysomnography under Autoset showed a significant reduction of abnormal respiratory events (apnea-hypopnea index (AHI): 5.7 (+/-4.6) vs 69.6 (+/-29.8) n/h; p<0.001). P95 was between 8.5 and 15 cm H2O (mean: 11.2 (+/-1.6)). Two patients were lost to follow-up. At 3 months, 18 out of 22 (82%) patients declared that they were still using their machine with a daily usage of 5.25 (+/-1.82) h. The Epworth sleepiness scale was significantly decreased (5 (+/-4.1) vs 11.4 (+/-5.4); p<0.05). P95 recommended by Autoset remained effective on abnormal respiratory events with a low AHI (4.1 (+/-3.2) n/h) and a low 4% oxygen desaturation index (3.6 (+/-4.5) n/h) under CPAP. This study confirms the efficacy of autotitration and the suitability of P95 determined by Autoset for long-term treatment by conventional CPAP at home.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/22.8.1095

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Gagnadoux, F., Rakotonanahary, D., de Araujo, M. M., Barros-Vieira, S., & Fleury, B.
Venue
Sleep
Published
1999-12
Volume
22
Issue
8
Pages
1095-1099
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W118371972
Cited by
46
References
0
FWCI
1.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term Efficacy of Fixed CPAP Recommended by Autoset® for OSAS. https://app.cochat.ai/papers/10.1093/sleep/22.8.1095
The paper
Gagnadoux, F., Rakotonanahary, D., de Araujo, M. M., Barros-Vieira, S., & Fleury, B. (1999). Long-term Efficacy of Fixed CPAP Recommended by Autoset® for OSAS. Sleep. https://doi.org/10.1093/sleep/22.8.1095

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.