CoChat

Noninvasive Cardiovascular Markers of Acoustically Induced Arousal from Non–rapid-eye-movement Sleep

Catcheside, Peter G., Orr, R. Stan, Chiong, Siau Chien, Mercer, Jeremy, Saunders, Nicholas A., McEvoy, R. Douglas · 2002 · Sleep
Cited by 84

The DOI matches its Crossref record.

Abstract

STUDY OBJECTIVES: Changes in cardiovascular measures such as heart rate (HR) and pulse transit time (PTT) have been advocated as sensitive markers of autonomic arousal from sleep. In animal studies, alerting stimuli produce particularly marked skin vascular responses. We hypothesized that changes in skin vascular conductance would provide more sensitive markers of autonomic arousal during sleep compared to central cardiovascular response measures such as HR and PTT. DESIGN: Cardiovascular responses to auditory-induced arousals were recorded during overnight sleep studies. SETTING: Sleep disorders unit in a 270-bed teaching hospital. PARTICIPANTS: Eleven young healthy male subjects. INTERVENTIONS: Throughout ovemight sleep studies, auditory tones (5-second duration, 54-90 decibels, 22-56 per subject) were presented during non-rapid-eye-movement sleep. Beat-by-beat HR, PTT, laser-Doppler fingertip skin blood flow (SBF) and finger and ear photoplethysmogram pulse wave amplitudes (PWA) were measured in the 20 seconds preceding and 30 seconds following each tone and compared to control measurements obtained during 50-second periods of recording with no stimulus (no tone, 6-22 per subject). Electroencephalographic (EEG) arousals were scored according to standard criteria (American Sleep Disorders Association) into no discemible, 3- to 10-second duration, or 10- to 15-second duration arousals. Poststimulus cardiovascular measurements were expressed as a percentage of the prestimulus mean and response magnitudes quantified from peak responses and the area under the poststimulus response curve. The ability of each cardiovascular response measure to discriminate EEG arousals (EEG changes lasting more than 3 seconds) was assessed from the area under the receiver operating characteristic (ROC) curve. MEASUREMENTS AND RESULTS: There were no significant changes in any cardiovascular parameter during control recordings. In contrast to all other parameters, finger PWA and SBF decreased following tones that produced no discernible EEG arousal (P < 0.05). A significant HR rise and decreases in all cardiovascular measures occurred with greater than 3-second arousals, with longer duration arousals generally exhibiting larger responses. Conventional EEG arousals (greater than 3 seconds) were relatively poorly detected from HR responses (ROC area HR rise 0.80 +/- 0.04) compared to changes in SBF (0.85 +/- 0.02), PTT (0.85 +/- 0.03) and finger PWA (0.90 +/- 0.01). CONCLUSIONS: Decreases in skin vascular conductance (finger PWA and SBF) provide sensitive markers of autonomic arousal during sleep. They are at least as sensitive as PTT for detecting conventionally scored EEG arousals and may be more sensitive in detecting "subcortical" arousals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/25.7.797

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Catcheside, P. G., Orr, R. S., Chiong, S. C., Mercer, J., Saunders, N. A., & McEvoy, R. D.
Venue
Sleep
Published
2002-10
Volume
25
Issue
7
Pages
797-804
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2419256150
Cited by
84
References
0
FWCI
2.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.