Pulse Transit Time and Blood Pressure Changes Following Auditory-Evoked Subcortical Arousal and Waking of Infants
Open accessAbstract
STUDY OBJECTIVES: To establish a normal range of data in 3-month-old infants in relation to changes in cardiovascular measurements, with particular reference to pulse transit time (PTT), following subcortical arousals and awakenings from sleep. DESIGN: Prospective study. SETTING: Sleep laboratory, Dunedin Hospital PARTICIPANTS: Twenty healthy infants aged 9-12 weeks. METHODS: Nap studies were performed using a standard polysomnographic setup with the addition of a Portapres blood pressure (BP) cuff (wrist application) and a piezoelectric sensor on the foot. PTT was measured from the ECG-R waveform to the arrival of the pulse peripherally. Infants were exposed to white noise from 50 to 100 dB at 10 dB intervals within REM and NREM sleep. RESULTS: Awakening thresholds were higher (P = 0.01) in NREM (>90 dB) than REM sleep (mean +/- SD; 74.3 +/- 9.4dB). Subcortical thresholds were always 10 dB below waking thresholds. Following awakening, there was an immediate increase in HR, SBP, and DBP of 21%, 14%, and 17%, respectively, and a 13% decrease in PTT returning to baseline within 25-30 seconds. PTT at baseline measured 140 +/- 11 and 139 +/- 9 msec in NREM and REM sleep, respectively, and decreased approximately 20 msec with waking. PTT changes were negatively correlated with heart rate (HR) but not BP, although a trend was evident. CONCLUSIONS: At 3 months of age, infants provoked to arouse from sleep showed PTT changes that inversely mimicked BP trends, suggesting that PTT could be useful in infant studies as a marker for autonomic perturbations that occur during sleep in both clinical and research settings.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Some studies suggest that the exclusion of the PEP from the PAT may improve correlation with SBP.
“Some studies suggest that the exclusion of the PEP from the PAT may improve correlation with SBP31,32.”
From Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units (2020) · cites this paper as [32]
PAT correlates with blood pressure in infants.
“with prior reports providing evidence that PAT correlates with blood pressure in infants (35–37).”
From Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care (2019) · cites this paper as [37]
Cites
Prolongation of the QT Interval and the Sudden Infant Death Syndrome
Schwartz, P. J., Stramba‐Badiale, M., Segantini, A., Austoni, P., Bosi, G., Giorgetti, R., Grancini, F., Marni, E., Perticone, F., Rosti, D., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199806113382401 · Cited by 686 · see citing works
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · see citing works
Responses to auditory stimulation, sleep loss and the EEG stages of sleep
Williams, H. L., Hammack, J. T., Daly, R. L., Dement, W. C., & Lubin, A. (1964) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(64)90109-9 · Cited by 366 · see citing works
Pulse transit time: an appraisal of potential clinical applications
Smith, R., ARGOD, J., Pépin, J., & Levy, P. A. (1999) · Thorax · doi:10.1136/thx.54.5.452 · Cited by 318 · see citing works
The Effect of Nonvisible Sleep Fragmentation on Daytime Function
Martin, S. E., WRAITH, P. K., Deary, I. J., & Douglas, N. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154863 · Cited by 274 · see citing works
Katz, E. S., Lutz, J., Black, C., & Marcus, C. L. (2003) · Pediatric Research · doi:10.1203/01.pdr.0000057206.14698.47 · Cited by 215 · see citing works
Arousal pattern following central and obstructive breathing abnormalities in infants and children
McNamara, F., Issa, F. G., & Sullivan, C. E. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2651 · Cited by 212 · see citing works
Pitson, D., & Stradling, J. R. (1998) · Journal of Sleep Research · doi:10.1046/j.1365-2869.1998.00092.x · Cited by 185 · see citing works
Changes in Pulse Transit Time and Pulse Rate as Markers of Arousal from Sleep in Normal Subjects
Pitson, D., Chhina, N., Knijn, S., van Herwaaden, M., & Stradling, J. R. (1994) · Clinical Science · doi:10.1042/cs0870269 · Cited by 172 · see citing works
Pitson, D., Sandell, A., van den Hout, R., & Stradling (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08101669 · Cited by 167 · see citing works
Experimental Sleep Fragmentation
Roehrs, T., Merlotti, L. A., Petrucelli, N., Stepanski, E. J., & Roth, T. G. (1994) · SLEEP · doi:10.1093/sleep/17.5.438 · Cited by 136 · see citing works
Auditory arousal thresholds are higher when infants sleep in the prone position
Franco, P., Pardou, A., Hassid, S., Lurquin, P., Groswasser, J., & Kahn, A. (1998) · The Journal of Pediatrics · doi:10.1016/s0022-3476(98)70438-x · Cited by 127 · see citing works
Pitson, D., & Stradling (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12030685 · Cited by 123 · see citing works
Pulse Transit Time Improves Detection of Sleep Respiratory Events and Microarousals in Children
Pépin, J., Delavie, N., Pin, I., Deschaux, C., Argod, J., Bost, M., & Levy, P. A. (2005) · CHEST Journal · doi:10.1378/chest.127.3.722 · Cited by 121 · see citing works
Ontogenetic variations in auditory arousal threshold during sleep
Busby, K., Mercier, L., & Pivik, R. T. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb01038.x · Cited by 120 · see citing works
Arousal and breathing responses to airway occlusion in healthy sleeping adults
Issa, F., & Sullivan, C. E. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.55.4.1113 · Cited by 117 · see citing works
Decreased Cardiac Responses to Auditory Stimulation During Prone Sleep
Franco, P., Groswasser, J., Sottiaux, M., Broadfield, E., & Kahn, A. (1996) · PEDIATRICS · doi:10.1542/peds.97.2.174 · Cited by 107 · see citing works
Cardiac and Respiratory Patterns in Normal Infants and Victims of the Sudden Infant Death Syndrome
Schechtman, V. L., Harper, R. M., Kluge, K. A., et al. (1988) · SLEEP · doi:10.1093/sleep/11.5.413 · Cited by 100 · see citing works
Criteria for set point estimation in the volume clamp method of blood pressure measurement.
Peňáz, J. (1992) · PubMed · Cited by 97 · see citing works
Noninvasive Cardiovascular Markers of Acoustically Induced Arousal from Non–rapid-eye-movement Sleep
CATCHESIDE, P. G., Orr, R. S., Chiong, S. C., Mercer, J., Saunders, N. A., & McEvoy, R. D. (2002) · SLEEP · doi:10.1093/sleep/25.7.797 · Cited by 84 · see citing works
Autonomic Reflexes in Preterm Infants
Lagercrantz, H., Edwards, D. A., Henderson-Smart, D. J., Hertzberg, T., & Jeffery, H. E. (1990) · Acta Paediatrica · doi:10.1111/j.1651-2227.1990.tb11546.x · Cited by 79 · see citing works
The scoring of arousals in healthy term infants (between the ages of 1 and 6 months)
THE INTERNATIONAL PAEDIATRIC WORK GROUP ON AROUSALS (2005) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2004.00426.x · Cited by 76 · see citing works
Franco, P., Szliwowski, H. B., Dramaix, M., & Kahn, A. (1998) · Clinical Autonomic Research · doi:10.1007/bf02277969 · Cited by 57 · see citing works
Ambient Temperature is Associated with Changes in Infants' Arousability from Sleep
Franco, P., Scaillet, S., Ir, F. V., Chabanski, S., Groswasser, J., & Kahn, A. (2001) · SLEEP · doi:10.1093/sleep/24.3.325 · Cited by 55 · see citing works
Dynamic Changes in Arousal Threshold during Sleep in the Human Infant
Read, P. A., Horne, R. S. C., Cranage, S. M., WALKER, A. M., Walker, D. W., & Adamson, T. M. (1998) · Pediatric Research · doi:10.1203/00006450-199805000-00020 · Cited by 55 · see citing works
Assessment of spontaneous baroreflex sensitivity in neonates
Drouin, E., Gournay, V., Calamel, J., et al. (1997) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.76.2.f108 · Cited by 55 · see citing works
Autonomic response to auditory stimulation
Anderssen, S.-H., Nicolaisen, R., & Gw, G. (1993) · Acta Paediatrica · doi:10.1111/j.1651-2227.1993.tb12598.x · Cited by 49 · see citing works
Functions of Sleep Architecture and the Concept of Protective Fields
Voss, U. (2004) · Reviews in the Neurosciences · doi:10.1515/revneuro.2004.15.1.33 · Cited by 48 · see citing works
Harrington, C. T., Kirjavainen, T., Teng, A. Y., & Sullivan, C. E. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.561 · Cited by 46 · see citing works
AUDITORY AROUSAL THRESHOLDS OF NORMAL AND NEAR‐MISS SIDS INFANTS
Kahn, A., Picard, E., & Blum, D. (1986) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1986.tb03876.x · Cited by 45 · see citing works
Habituation of the Infant Arousal Response
McNamara, F., Wulbrand, H., & Thach, B. T. (1999) · SLEEP · doi:10.1093/sleep/22.3.320 · Cited by 45 · see citing works
SUDDEN INFANT DEATH SYNDROME EPIDEMIOLOGY: A REVIEW AND UPDATE
Little, R. E., & Peterson, D. R. (1990) · Epidemiologic Reviews · doi:10.1093/oxfordjournals.epirev.a036057 · Cited by 37 · see citing works
Sensitivity of sleep stages to painful thermal stimuli
Bentley, A., Newton, S., & Zio, C. D. (2003) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2003.00352.x · Cited by 36 · see citing works
Feasibility of using finger arterial pressure in neonates
Drouin, E., Gournay, V., Calamel, J., Mouzard, A., & Rozé, J. (1997) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.77.2.f139 · Cited by 36 · see citing works
Increased Cardiac Autonomic Responses to Auditory Challenges in Swaddled Infants
Franco, P., Scaillet, S., Groswasser, J., & Kahn, A. (2004) · SLEEP · doi:10.1093/sleep/27.8.1527 · Cited by 28 · see citing works
Acoustic arousal responses in children with obstructive sleep apnea
Moreira, G. A., Tufik, S. B., Nery, L. E., Lutz, J., Verfaille, K., Luan, X., & Marcus, C. L. (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20219 · Cited by 24 · see citing works
McGraw, M. B. (1937) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1937.01980020034003 · Cited by 24 · see citing works
Responses to an increasing asphyxia in infants: effects of age and sleep state
Campbell, A. J., Bolton, D., Taylor, B. J., et al. (1998) · Respiration Physiology · doi:10.1016/s0034-5687(98)00008-5 · Cited by 23 · see citing works
Self-citationPhysiological relationship between autonomic reactions and arousals in infancy
Franco, P., van de Borne, P., Chabanski, S., Sawaguchi, T., Horne, R. S. C., Verheulpen, D., Groswasser, J., & Kahn, A. (2002) · Sleep Medicine · doi:10.1016/s1389-9457(02)00165-x · Cited by 18 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807 · see citing works
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482 · see citing works
The use of pulse transit time in pediatric sleep studies: A systematic review
Smith, L. A., Dawes, P. J., & Galland, B. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.11.006 · Cited by 22 · see citing works
Self-citation
- Authors
- Galland, B. C., Tan, E., & Taylor, B. J.
- Affiliations
- University of Otago (NZ)
- Corresponding author
- Galland, Barbara C.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-07
- Volume
- 30
- Issue
- 7
- Pages
- 891-897
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- PMC
- PMC1978362
- OpenAlex
- W2149175862
- Cited by
- 34
- References
- 40
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 4 · 2020: 2 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 5 · 2012: 1
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- SLEEP (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Life Sciences › Neuroscience › Cognitive Neuroscience › Sleep and Wakefulness Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- pulse transit time, blood pressure, infant sleep, auditory stimulation, REM sleep, NREM sleep, heart rate, autonomic nervous system, white noise, reference values
- MeSH terms
- Arousal, Blood Pressure, Electroencephalography, Electromyography, Electrooculography, Evoked Potentials, Auditory, Female, Heart Rate, Humans, Infant, Male, Oxygen, Prospective Studies, Sleep, REM, Wakefulness, Polysomnography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review