Cited by 34Heart Rate Variability and Autonomic ControlSleep and Wakefulness ResearchNon-Invasive Vital Sign Monitoring

Pulse Transit Time and Blood Pressure Changes Following Auditory-Evoked Subcortical Arousal and Waking of Infants

Open access
Galland, Barbara C., Tan, Evan, Taylor, Barry J.·2007·Sleep

Abstract

STUDY OBJECTIVES: To establish a normal range of data in 3-month-old infants in relation to changes in cardiovascular measurements, with particular reference to pulse transit time (PTT), following subcortical arousals and awakenings from sleep. DESIGN: Prospective study. SETTING: Sleep laboratory, Dunedin Hospital PARTICIPANTS: Twenty healthy infants aged 9-12 weeks. METHODS: Nap studies were performed using a standard polysomnographic setup with the addition of a Portapres blood pressure (BP) cuff (wrist application) and a piezoelectric sensor on the foot. PTT was measured from the ECG-R waveform to the arrival of the pulse peripherally. Infants were exposed to white noise from 50 to 100 dB at 10 dB intervals within REM and NREM sleep. RESULTS: Awakening thresholds were higher (P = 0.01) in NREM (>90 dB) than REM sleep (mean +/- SD; 74.3 +/- 9.4dB). Subcortical thresholds were always 10 dB below waking thresholds. Following awakening, there was an immediate increase in HR, SBP, and DBP of 21%, 14%, and 17%, respectively, and a 13% decrease in PTT returning to baseline within 25-30 seconds. PTT at baseline measured 140 +/- 11 and 139 +/- 9 msec in NREM and REM sleep, respectively, and decreased approximately 20 msec with waking. PTT changes were negatively correlated with heart rate (HR) but not BP, although a trend was evident. CONCLUSIONS: At 3 months of age, infants provoked to arouse from sleep showed PTT changes that inversely mimicked BP trends, suggesting that PTT could be useful in infant studies as a marker for autonomic perturbations that occur during sleep in both clinical and research settings.

Integrity signals

Registry

Crossref · 10.1093/sleep/30.7.891

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Galland, B. C., Tan, E., & Taylor, B. J.
Affiliations
University of Otago (NZ)
Corresponding author
Galland, Barbara C.
Venue
Sleep
Published
2007-07
Volume
30
Issue
7
Pages
891-897
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2149175862
Cited by
34
References
40
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 4 · 2020: 2 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 5 · 2012: 1
FWCI
0.70
Type
journal article
Language
en
Open access
Locations
  • SLEEP (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Sleep and Wakefulness Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
pulse transit time, blood pressure, infant sleep, auditory stimulation, REM sleep, NREM sleep, heart rate, autonomic nervous system, white noise, reference values
MeSH terms
Arousal, Blood Pressure, Electroencephalography, Electromyography, Electrooculography, Evoked Potentials, Auditory, Female, Heart Rate, Humans, Infant, Male, Oxygen, Prospective Studies, Sleep, REM, Wakefulness, Polysomnography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review