Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Sleep During Titration Predicts Continuous Positive Airway Pressure Compliance

Drake, Christopher L., Day, Ryan, Hudgel, David, Stefadu, Yevgeniy, Parks, Mary, Syron, Mary Lou, Roth, Thomas·2003·Sleep

Abstract

STUDY OBJECTIVES: Poor compliance with continuous positive airway pressure (CPAP) has been identified as a significant obstacle in the treatment of obstructive sleep apnea. While previous studies have focused on diagnostic screening variables, side effects, health beliefs, and measures of disease severity, investigators have generally ignored sleep parameters assessed during CPAP titration as predictors of compliance. As the titration night represents patients' initial exposure to nocturnal CPAP treatment, we hypothesized that nocturnal polysomnographic (PSG) variables, representing improved sleep at this time, would predict higher subsequent compliance. DESIGN: Prospective analyses of a sequential case series were undertaken using nocturnal PSG variables during titration as early predictors of CPAP compliance. SETTING: Accredited sleep center. PATIENTS: Seventy-one patients with sleep apnea, aged 31-78 years, with a mean respiratory disturbance index of 62.0 +/- 32.2. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: Compliance was calculated as mean hours per night of CPAP use over the initial follow-up period (mean 46.9 days). Standard PSG variables and subjective reports of sleep were used as predictive variables in multivariate analyses. Mean objective compliance was 5.04 hours per night +/- 2.59. Consistent with our hypothesis, the best predictor of compliance was change in sleep efficiency (SE) from diagnostic to titration night [F (1,66) = 17.31, p < .000 (r = .48)], indicating that patients whose sleep improved most on the titration night had the highest levels of compliance. This relationship was also significant after controlling for measures of disease severity obtained during the diagnostic testing night. Importantly, individuals whose sleep improved on the CPAP titration night had nightly compliance rates of approximately 2 hours greater than patients whose sleep did not improve during titration. CONCLUSIONS: The findings suggest that patients' initial experience with CPAP treatment and, in particular, the degree of improvement in sleep during CPAP titration may be crucial factors in determining their subsequent use of this treatment modality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/26.3.308

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 210

Metadata

Authors
Drake, C. L., Day, R., Hudgel, D., Stefadu, Y., Parks, M., Syron, M. L., & Roth, T.
Venue
Sleep
Published
2003-05
Volume
26
Issue
3
Pages
308-311
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W104120026
Cited by
210
References
7
FWCI
3.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sleep During Titration Predicts Continuous Positive Airway Pressure Compliance. https://app.cochat.ai/papers/10.1093/sleep/26.3.308
The paper
Drake, C. L., Day, R., Hudgel, D., Stefadu, Y., Parks, M., Syron, M. L., & Roth, T. (2003). Sleep During Titration Predicts Continuous Positive Airway Pressure Compliance. Sleep. https://doi.org/10.1093/sleep/26.3.308

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.