An ECG-based Algorithm for the Automatic Identification of Autonomic Activations Associated with Cortical Arousal
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: EEG arousals are associated with autonomic activations. Visual EEG arousal scoring is time consuming and suffers from low interobserver agreement. We hypothesized that information on changes in heart rate alone suffice to predict the occurrence of cortical arousal. METHODS: Two visual AASM EEG arousal scorings of 56 healthy subject nights (mean age 37.0 +/- 12.8 years, 26 male) were obtained. For each of 5 heartbeats following the onset of 3581 consensus EEG arousals and of an equal number of control conditions, differences to a moving median were calculated and used to estimate likelihood ratios (LRs) for 10 categories of heartbeat differences. Comparable to 5 consecutive diagnostic tests, these LRs were used to calculate the probability of heart rate responses being associated with cortical arousals. RESULTS: EEG and ECG arousal indexes agreed well across a wide range of decision thresholds, resulting in a receiver operating characteristic (ROC) with an area under the curve of 0.91. For the decision threshold chosen for the final analyses, a sensitivity of 68.1% and a specificity of 95.2% were obtained. ECG and EEG arousal indexes were poorly correlated (r = 0.19, P <0.001, ICC = 0.186), which could in part be attributed to 3 outliers. The Bland-Altman plot showed an unbiased estimation of EEG arousal indexes by ECG arousal indexes with a standard deviation of +/- 7.9 arousals per hour sleep. In about two-thirds of all cases, ECG arousal scoring was matched by at least one (22.2%) or by both (42.5%) of the visual scorings. Sensitivity of the algorithm increased with increasing duration of EEG arousals. The ECG algorithm was also successfully validated with 30 different nights of 10 subjects (mean age 35.3 [ 13.6 years, 5 male). CONCLUSIONS: In its current version, the ECG algorithm cannot replace visual EEG arousal scoring. Sensitivity for detecting <10-s EEG arousals needs to be improved. However, in a nonclinical population, it may be valuable to supplement visual EEG arousal scoring by this automatic, objective, reproducible, cheap, and time-saving method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Decision Making in Health and Medicine: Integrating Evidence and Values
Hunink, M. G. M., Weinstein, M. C., Wittenberg, E., Drummond, M. F., Pliskin, J. S., Wong, J. B., & Glasziou, P. P. (2014) · doi:10.1017/cbo9781139506779 · Cited by 425
Cited by
Cardiovascular effects of environmental noise exposure
Munzel, T., Gori, T., Babisch, W., & Basner, M. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu030 · Cited by 820
Self-citationBasner, M., & McGuire, S. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15030519 · Cited by 573
Self-citationSleep stage classification from heart-rate variability using long short-term memory neural networks
Radha, M., Fonseca, P., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-49703-y · Cited by 186
Sleep stage classification with ECG and respiratory effort
Fonseca, P., Long, X., Radha, M., Haakma, R., Aarts, R. M., & Rolink, J. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/10/2027 · Cited by 168
“%) of detrended and non-detrended heart rates and heartbeat intervals (Ylmaz et al 2010, Willemen et al 2014) as well as the mean, median, minimal, and maximal likelihood ratios of heart rates (Basner et al 2007).”
BackgroundSleep Disruption due to Hospital Noises: A Prospective Evaluation
Buxton, O. M., Ellenbogen, J. M., Wang, W., Carballeira, A., O'Connor, S., Cooper, D., Gordhandas, A. J., McKinney, S. M., & Solet, J. M. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-12-201208070-00472 · Cited by 163
Metadata
- Authors
- Basner, M., Griefahn, B., Müller, U., Plath, G., & Samel, A.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-10
- Volume
- 30
- Issue
- 10
- Pages
- 1349-1361
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2145743401
- Cited by
- 58
- References
- 4
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An ECG-based Algorithm for the Automatic Identification of Autonomic Activations Associated with Cortical Arousal. https://app.cochat.ai/papers/10.1093/sleep/30.10.1349
- The paper
- Basner, M., Griefahn, B., Müller, U., Plath, G., & Samel, A. (2007). An ECG-based Algorithm for the Automatic Identification of Autonomic Activations Associated with Cortical Arousal. Sleep. https://doi.org/10.1093/sleep/30.10.1349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.