CoChat

Efficacy and Safety of 6-Month Nightly Ramelteon Administration in Adults with Chronic Primary Insomnia

Open access
Geert Mayer, GeertSherry Wang-Weigand, Barbara F. Roth‐Schechter, Reiner Lehmann, Corinne Staner, Markku Partinen · 2009 · SLEEP
Cited by 145

The DOI matches its OpenAlex record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Long-duration (> or = 6 months) polysomnographic studies of insomnia medications are lacking. This study evaluated the long-term efficacy of ramelteon, a selective MT1/MT2 melatonin-receptor agonist used for insomnia treatment. DESIGN: Six-month, randomized, double-blind, placebo-controlled study. SETTING: Forty-six investigative sites in the United States, Europe, Russia, and Australia. PARTICIPANTS: Four hundred fifty-one adults (age > or = 18 years) with chronic primary insomnia. INTERVENTIONS: Ramelteon, 8 mg, or placebo 30 minutes before bedtime nightly for 6 months. MEASUREMENTS: Sleep was evaluated by polysomnography and morning questionnaires on the first 2 nights of Week 1; the last 2 nights of Months 1, 3, 5, and 6; and Nights 1 and 2 of the placebo run-out. Next-morning residual effects as well as adverse effects and vital signs were recorded at each visit. Rebound insomnia and withdrawal effects were evaluated during placebo run-out. RESULTS: Over the 6 months of treatment, ramelteon consistently reduced latency to persistent sleep compared with baseline and with placebo; significant decreases were observed at Week 1 and Months 1, 3, 5, and 6 (P < 0.05). Ramelteon significantly reduced subjective sleep latency relative to placebo at Week 1, Month 1, and Month 5 (P < 0.05), with reductions nearing statistical significance at Months 3 and 6 (P < or = 0.08). No significant next-morning residual effects were detected during ramelteon treatment. No withdrawal symptoms or rebound insomnia were detected after ramelteon discontinuation. Most adverse events were mild or moderate in severity. CONCLUSIONS: In adults with chronic insomnia, long-term ramelteon treatment consistently reduced sleep onset, with no next-morning residual effects or rebound insomnia or withdrawal symptoms upon discontinuation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1093/sleep/32.3.351

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 145

Metadata

Authors
Mayer, G., Wang-Weigand, G., Roth‐Schechter, B. F., Lehmann, R., Staner, C., & Partinen, M.
Venue
SLEEP
Published
2009-03-01
Volume
32
Issue
3
Pages
351-360
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W1532372165
Cited by
145
References
9
FWCI
19.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.