The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
State of the science and recommendations for using wearable technology in sleep and circadian research
Open accessAbstract
Wearable sleep-tracking technology is of growing use in the sleep and circadian fields, including for applications across other disciplines, inclusive of a variety of disease states. Patients increasingly present sleep data derived from their wearable devices to their providers and the ever-increasing availability of commercial devices and new-generation research/clinical tools has led to the wide adoption of wearables in research, which has become even more relevant given the discontinuation of the Philips Respironics Actiwatch. Standards for evaluating the performance of wearable sleep-tracking devices have been introduced and the available evidence suggests that consumer-grade devices exceed the performance of traditional actigraphy in assessing sleep as defined by polysomnogram. However, clear limitations exist, for example, the misclassification of wakefulness during the sleep period, problems with sleep tracking outside of the main sleep bout or nighttime period, artifacts, and unclear translation of performance to individuals with certain characteristics or comorbidities. This is of particular relevance when person-specific factors (like skin color or obesity) negatively impact sensor performance with the potential downstream impact of augmenting already existing healthcare disparities. However, wearable sleep-tracking technology holds great promise for our field, given features distinct from traditional actigraphy such as measurement of autonomic parameters, estimation of circadian features, and the potential to integrate other self-reported, objective, and passively recorded health indicators. Scientists face numerous decision points and barriers when incorporating traditional actigraphy, consumer-grade multi-sensor devices, or contemporary research/clinical-grade sleep trackers into their research. Considerations include wearable device capabilities and performance, target population and goals of the study, wearable device outputs and availability of raw and aggregate data, and data extraction, processing, and analysis. Given the difficulties in the implementation and utilization of wearable sleep-tracking technology in real-world research and clinical settings, the following State of the Science review requested by the Sleep Research Society aims to address the following questions. What data can wearable sleep-tracking devices provide? How accurate are these data? What should be taken into account when incorporating wearable sleep-tracking devices into research? These outstanding questions and surrounding considerations motivated this work, outlining practical recommendations for using wearable technology in sleep and circadian research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
National Sleep Foundation's sleep time duration recommendations: methodology and results summary.
Hirshkowitz, M., Whiton, K., Albert, S. M., Alessi, C., Bruni, O., DonCarlos, L., Hazen, N., Herman, J., Katz, E. S., Kheirandish-Gozal, L., et al. (2015) · Sleep Health · doi:10.1016/j.sleh.2014.12.010 · Cited by 4,404 · cited 1×
“Based on biological changes, the recommended sleep durations for age groups are as follows: 10–13 h for ages 3–5 years, 9–11 h for ages 6–13 years, 8–10 h for ages 14–17 years, 7–9 h for ages 18–64 years, and 7–8 h for > 65 years [123].”
Ohayon, M. M., Carskadon, M. A., Guilleminault, C., & Vitiello, M. V. (2004) · Sleep · doi:10.1093/sleep/27.7.1255 · Cited by 3,349
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212
The Role of Actigraphy in the Study of Sleep and Circadian Rhythms
Ancoli-Israel, S., Cole, R., Alessi, C., Chambers, M., Moorcroft, W., & Pollak, C. P. (2003) · Sleep · doi:10.1093/sleep/26.3.342 · Cited by 2,751 · cited 5×
“However, because circadian rhythms are sometimes non-sinusoidal, alternatives such as transformation of the cosine curve or other nonparametric methods often result in a better fit to activity data [37, 38].”
InfluentialNahum-Shani, I., Smith, S. N., Spring, B. J., Collins, L. M., Witkiewitz, K., Tewari, A., & Murphy, S. A. (2018) · Annals of Behavioral Medicine · doi:10.1007/s12160-016-9830-8 · Cited by 2,171 · cited 1×
“Further building on ESM, wearable devices are a powerful input to just-in-time-adapitve interventions [144], personalized interventions delivered in real-time in response to changes in an individual’s internal and contextual state.”
Diagnosis and Management of Obstructive Sleep Apnea: A Review
Gottlieb, D. J., & Punjabi, N. M. (2020) · JAMA · doi:10.1001/jama.2020.3514 · Cited by 1,482 · cited 1×
“Given the relevance of OSA for daytime function, management of certain chronic conditions, and risk of incident disease (particularly cardiovascular) [91], the lack of high-quality evidence regarding the ability of consumer-grade wearables to detect OSA prevents their use as a diagnostic tool.”
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415 · cited 2×
“For both children and adults, proportional biases have been reported across indices of both sleep duration and disturbances, generally pointing toward a greater inaccuracy of the devices on nights with more disturbed sleep, a well-known recognized limitation in the actigraphy literature [57].”
A novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744 · cited 1×
“Machine learning analysis of data acquired with contemporary research/clinical-grade devices provides a novel methodology that may be superior to original algorithms to quantify sleep from raw acceleration data [73] and may even identify off-wrist time [74].”
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Cited by
One-year actigraphy study of sleep and rest-activity rhythms as markers of relapse in depression
Tonon, A. C., Nexha, A., Cunningham, J. E. A., d’Eon, J., Chakrabarty, T., Farzan, F., Foster, J. A., Harkness, K. L., Hassel, S., Ho, K., et al. (2026) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2025.4453 · Cited by 9
Bulman, A., McKune, A., Georgousopoulou, E., Sergi, D., & Naumovski, N. (2026) · Contemporary Clinical Trials · doi:10.1016/j.cct.2026.108306 · Cited by 1
Metadata
- Authors
- de Zambotti, M., Goldstein, C., Cook, J., Menghini, L., Altini, M., Cheng, P., & Robillard, R.
- Venue
- SLEEP
- Publisher
- Oxford University Press (OUP)
- Published
- 2023-12-27
- Volume
- 47
- Issue
- 4
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W4390258985
- Cited by
- 250
- References
- 38
- FWCI
- 58.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: State of the science and recommendations for using wearable technology in sleep and circadian research. https://app.cochat.ai/papers/10.1093/sleep/zsad325
- The paper
- de Zambotti, M., Goldstein, C., Cook, J., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2024). State of the science and recommendations for using wearable technology in sleep and circadian research. SLEEP. https://doi.org/10.1093/sleep/zsad325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.